Skip to main content
Log in

Chemiluminescence determination of chromium(III) and total chromium in water samples using the periodate-lucigenin reaction

  • Original Paper
  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract.

A new chemiluminescence (CL) method combined with flow injection technique is described for the determination of Cr(III) and total Cr. It is found that a strong CL signal is generated from the reaction of Cr(III), lucigenin and KIO4 in alkaline condition. The determination of total Cr is performed by pre-reduction of Cr(VI) to Cr(III) by using H2SO3. The CL intensity is linearly related to the concentration of Cr in the range 4.0 × 10−10–1.0 × 10−6 g mL−1. The detection limit (3s b) is 1 × 10−10 g mL−1 Cr and the relative standard deviation is 1.9% (5.0 × 10−8 g mL−1 of Cr(III) solution, n = 11). The method was applied to the determination of Cr(III) and total Cr in water samples and compared satisfactorily with the official method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • J Chwastowska W Skwara E Sterlinska L Pszonicki (2005) ArticleTitleSpeciation of chromium in mineral waters and salinas by solid-phase extraction and graphite furnace atomic absorption spectrometry Talanta 66 1345 Occurrence Handle10.1016/j.talanta.2005.01.055 Occurrence Handle1:CAS:528:DC%2BD2MXltFGksb4%3D

    Article  CAS  Google Scholar 

  • J Nan X P Yan (2005) ArticleTitleOn-line dynamic two-dimensional admicelles solvent extraction coupled to electrothermal atomic absorption spectrometry for determination of chromium(VI) in drinking water Anal Chim Acta 536 207 Occurrence Handle10.1016/j.aca.2004.12.045 Occurrence Handle1:CAS:528:DC%2BD2MXjtl2mtLk%3D

    Article  CAS  Google Scholar 

  • P Liang J Li (2005) ArticleTitleSpeciation of chromium with cloud point extraction separation and determination by ICP-OES Atom Spectrosc 26 89 Occurrence Handle1:CAS:528:DC%2BD2MXlslGgs74%3D

    CAS  Google Scholar 

  • R A Gil S Cerutti J A Gasquez R A Olsina L D Martinez (2005) ArticleTitleOn-line preconcentration and determination of chromium in parenteral solutions by inductively coupled plasma optical emission spectrometry Spectrochim Acta B 60 531 Occurrence Handle10.1016/j.sab.2005.02.008

    Article  Google Scholar 

  • M S El-Shahawi S S M Hassan A M Othman M A Zyada M A El-Sonbati (2005) ArticleTitleChemical speciation of chromium(III, VI) employing extractive spectrophotometry and tetraphenylarsonium chloride or tetraphenylphosphonium bromide as ion-pair reagent Anal Chim Acta 534 319 Occurrence Handle10.1016/j.aca.2004.11.085 Occurrence Handle1:CAS:528:DC%2BD2MXis1Cjtbs%3D

    Article  CAS  Google Scholar 

  • V Andruch M Telepcakawa I S Balogh N Urbanova (2003) ArticleTitleInvestigation of 2-[2-(4-Methoxy-phenylamino)-vinyl]-1,3,3-trimethyl-3H-indolium chloride as a new reagent for the determination of chromium(VI) Microchim Acta 142 109 Occurrence Handle10.1007/s00604-003-0019-z Occurrence Handle1:CAS:528:DC%2BD3sXkvFentbo%3D

    Article  CAS  Google Scholar 

  • S S M Hassan M S El-Shahawi A M Othman M A Mosaad (2005) ArticleTitleA potentiometric rhodamine-B based membrane sensor for the selective determination of chromium ions in wastewater Anal Sci 21 673 Occurrence Handle10.2116/analsci.21.673 Occurrence Handle1:CAS:528:DC%2BD2MXlsFers7c%3D

    Article  CAS  Google Scholar 

  • M Shamsipur A Soleymanpour M Akhond H Sharghi M H Sarvari (2005) ArticleTitleHighly selective chromium(III) PVC-membrane electrodes based on some recently synthesized Schiff’s bases Electroanal 17 776 Occurrence Handle10.1002/elan.200403152 Occurrence Handle1:CAS:528:DC%2BD2MXksFaks7w%3D

    Article  CAS  Google Scholar 

  • J Du J Li L Yang J Lu (2003) ArticleTitleSensitive and selective determination of molybdenum by flow injection chemiluminescence method combined with controlled potential electrolysis technique Anal Chim Acta 481 239 Occurrence Handle10.1016/S0003-2670(03)00083-7 Occurrence Handle1:CAS:528:DC%2BD3sXitFKjur4%3D

    Article  CAS  Google Scholar 

  • W F Niu N Feng F Nie J R Lu (2006) ArticleTitleInvestigating the post-chemiluminescence behavior of phenothiazine medications in the luminol-potassium ferricyanide system: molecular imprinting – post-chemiluminescence method for the determination of chlorpromazine hydrochloride Anal Bioanal Chem 385 153 Occurrence Handle10.1007/s00216-006-0365-x Occurrence Handle1:CAS:528:DC%2BD28XjslKjt7s%3D

    Article  CAS  Google Scholar 

  • J Du J Lu X Zhang (2006) ArticleTitleFlow-injection chemiluminescence determination of cobalt using a cobalt(II)(1,10-phenanthroline)3 complex-catalyzed lucigenin-periodate reaction Microchim Acta 153 21 Occurrence Handle10.1007/s00604-005-0452-2 Occurrence Handle1:CAS:528:DC%2BD28Xot1Sjtg%3D%3D

    Article  CAS  Google Scholar 

  • P Fletcher K N Andrew A C Calokerinos S Forbes P J Worsfold (2001) ArticleTitleAnalytical applications of flow injection with chemiluminescence detection – a review Luminescence 16 1 Occurrence Handle10.1002/bio.607 Occurrence Handle1:CAS:528:DC%2BD3MXisFymt7s%3D

    Article  CAS  Google Scholar 

  • W R Seitz W W Suydam D M Hercules (1972) ArticleTitleDetermination of trace amounts of chromium(III) using chemiluminescence analysis Anal Chem 44 957 Occurrence Handle10.1021/ac60314a011 Occurrence Handle1:CAS:528:DyaE38XhsFyisLY%3D

    Article  CAS  Google Scholar 

  • S Meseguer-Lloret P Campíns-Falcó L A Tortajada-Genaro F Blasco-Gómez (2003) ArticleTitleA guide to avoid method bias of chromium(III, VI) chemiluminescence determination by luminol-hydrogen peroxide reaction-application to water samples Int J Environ An Ch 85 405 Occurrence Handle10.1080/0306731031000101383

    Article  Google Scholar 

  • S Nakano N Teshima M Kurihara T Kawashima (2004) ArticleTitleFlow-injection determination of trace elements by using catalyzed reactions Bunseki Kagaku 53 255 Occurrence Handle10.2116/bunsekikagaku.53.255 Occurrence Handle1:CAS:528:DC%2BD2cXjtlGms70%3D

    Article  CAS  Google Scholar 

  • M Ohshima M Yamada S Suzuki (1990) ArticleTitleFlavin mononucleotide chemiluminescence in cationic micellar media for determination of chromium(III + VI) by flow injection Anal Chim Acta 232 385 Occurrence Handle10.1016/S0003-2670(00)81257-X Occurrence Handle1:CAS:528:DyaK3cXksFWktbY%3D

    Article  CAS  Google Scholar 

  • S Nakano M Fukuda S Kageyama H Itabashi T Kawashima (1993) ArticleTitleFlow injection determination of chromium(III) by pyrogallol chemiluminescence Talanta 40 75 Occurrence Handle10.1016/0039-9140(93)80143-F Occurrence Handle1:CAS:528:DyaK3sXhtlyrt7w%3D

    Article  CAS  Google Scholar 

  • K Filik (2002) ArticleTitlePreconcentration and speciation of chromium(III) in waters by using 5-palmitoyl-8-hydroxyquinoline immobilized on a nonpolar adsorbent Microchim Acta 140 205 Occurrence Handle10.1007/s00604-002-0909-5 Occurrence Handle1:CAS:528:DC%2BD38XovFyrtbo%3D

    Article  CAS  Google Scholar 

  • M Derbyshire A Lamberty P H E Gardiner (1999) ArticleTitleOptimization of the simultaneous determination of Cr(III) and Cr(VI) by ion chromatography with chemiluminescence detection Anal Chem 71 4203 Occurrence Handle10.1021/ac9902751 Occurrence Handle1:CAS:528:DyaK1MXlt12ksLw%3D

    Article  CAS  Google Scholar 

  • Z J Zhang J R Lu (1983) ArticleTitleChemiluminescence method for the monitor of Cr(VI) and Cr(III) in water samples Fenxi Ceshi Xuebao 2 86

    Google Scholar 

  • T Williams P Jones L Ebdon (1989) ArticleTitleSimultaneous determination of Cr(III) and Cr(VI) at ultratrace levels using ion chromatography with chemiluminescence detection J Chromatogr A 482 361 Occurrence Handle10.1016/S0021-9673(01)83924-8 Occurrence Handle1:CAS:528:DyaK3cXhs1Clsr0%3D

    Article  CAS  Google Scholar 

  • W P Yang Z J Zhang W Deng (2003) ArticleTitleSpeciation of chromium by in-capillary reaction and capillary electrophoresis with chemiluminescence detection J Chromatogr A 1014 203 Occurrence Handle10.1016/S0021-9673(03)00940-3 Occurrence Handle1:CAS:528:DC%2BD3sXnt1yrsrg%3D

    Article  CAS  Google Scholar 

  • InstitutionalAuthorNameEditorial Committee of Water and Wastewater Monitoring Method (1990) Water and wastewater monitoring method Environmental Science Press of China Beijing

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jian-Xiu Du.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Du, JX., Li, YH. & Guan, R. Chemiluminescence determination of chromium(III) and total chromium in water samples using the periodate-lucigenin reaction. Microchim Acta 158, 145–150 (2007). https://doi.org/10.1007/s00604-006-0681-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00604-006-0681-z

Navigation