Abstract.
Multi-wall carbon nanotubes (MWNT) were dispersed into water in the presence of dicetyl phosphate (DCP), and MWNT-DCP composite film coated glassy carbon electrodes (GCE) were constructed. The electrochemical properties of 2-chlorophenol at a bare GCE and MWNT-DCP modified GCE were compared. It was found that MWNT-DCP modified GCEs significantly enhance the oxidation peak current of 2-chlorophenol and lowers its oxidation overpotential, suggesting great potential in the sensitive determination of 2-chlorophenol. Finally, a sensitive and simple voltammetric method was developed for the determination of 2-chlorophenol. The oxidation peak current increases linearly with the concentration in the range of 1.0 × 10−7–2.0 × 10−5 mol L−1, and the detection limit is 4.0 × 10−8 mol L−1 for 2 min accumulation. The method was successfully used to determine 2-chlorophenol in waste water samples.
Similar content being viewed by others
References
F B Dewalle D A Kalman R Dills D Noram E S K Chain M Giabbai M Ghosal (1982) ArticleTitlePresence of phenolic-compounds in sewage, effluent and sludge from municipal sewage-treatment plants Water Sci Technol 14 143
A Dicorcia S Marchese R J Samperi (1993) ArticleTitleEvaluation of graphitized carbon-black as a selective adsorbent for extracting acidic organic-compounds from water J Chromatogr 642 163 Occurrence Handle10.1016/0021-9673(93)80084-L Occurrence Handle1:CAS:528:DyaK3sXmtlemsL4%3D
H Kontsas C Rosenberg P Jappinen M L Riekkola (1993) ArticleTitleGlass-fiber prefilter xad-2 sampling and gas-chromatographic determination of airborne chlorophenols J Chromatogr 636 255 Occurrence Handle10.1016/0021-9673(93)80239-5
I Rodriguez R Cela (1997) ArticleTitleCombination of solid-phase extraction procedures with gas chromatographic hyphenated techniques for chlorophenol determination in drinking water Trac-Trends in Anal Chem 16 463 Occurrence Handle10.1016/S0165-9936(97)00060-5 Occurrence Handle1:CAS:528:DyaK2sXmvVGmsbc%3D
H Kontsas C Rosenberg P Pfaffli P Jappinen (1995) ArticleTitleGas-chromatographic mass-spectrometric determination of chlorophenols in the urine of sawmill workers with past use of chlorophenol-containing antistain agents Analyst 120 1745 Occurrence Handle10.1039/an9952001745 Occurrence Handle1:CAS:528:DyaK2MXmtlOktL0%3D
M L Antonelli L Campanella P Ercole (2005) ArticleTitleLichen-based biosensor for the determination of benzene and 2-chlorophenol: microcalorimetric and amperometric investigations Anal Bioanal Chem 381 1041 Occurrence Handle10.1007/s00216-004-3014-2 Occurrence Handle1:CAS:528:DC%2BD2MXit1Cru7Y%3D
M S Ureta-Zanartu C Berrios J Pavez J Zagal C Gutierrez J F Marco (2003) ArticleTitleElectrooxidation of 2-chlorophenol on polyNiTSPc-modified glassy carbon electrodes J Electroanal Chem 553 147 Occurrence Handle10.1016/S0022-0728(03)00309-7 Occurrence Handle1:CAS:528:DC%2BD3sXmvF2ms7c%3D
S Iijima (1991) ArticleTitleHelical microtubules of graphite carbon Nature 354 56 Occurrence Handle10.1038/354056a0 Occurrence Handle1:CAS:528:DyaK38Xmt1Ojtg%3D%3D
P J Britto K S V Santhanam P M Ajayan (1996) ArticleTitleCarbon nanotube electrode for oxidation of dopamine Bioelectrochem Bioenerg 41 121 Occurrence Handle10.1016/0302-4598(96)05078-7 Occurrence Handle1:CAS:528:DyaK28Xls1Knt7k%3D
M Musamech J Wang A Merkoci Y H Lin (2002) ArticleTitleLow-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes Electrochem Commun 4 743 Occurrence Handle10.1016/S1388-2481(02)00451-4
K B Wu J J Fei S S Hu (2003) ArticleTitleSimultaneous determination of dopamine and serotonin on a glassy carbon electrode coated with a film of carbon nanotubes Anal Biochem 318 100 Occurrence Handle10.1016/S0003-2697(03)00174-X Occurrence Handle1:CAS:528:DC%2BD3sXktFWhtL4%3D
K B Wu S S Hu J J Fei B Wen (2003) ArticleTitleMercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-wall carbon nanotubes Anal Chim Acta 489 215 Occurrence Handle10.1016/S0003-2670(03)00718-9 Occurrence Handle1:CAS:528:DC%2BD3sXlvFGmtr0%3D
J Wang M Musameh Y H Lin (2003) ArticleTitleSolubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors J Am Chem Soc 125 2408 Occurrence Handle10.1021/ja028951v Occurrence Handle1:CAS:528:DC%2BD3sXpvVartA%3D%3D
S C Tsang Y K Chen P J E Harris M L H Green (1994) ArticleTitleA simple chemical method of opening and filling carbon nanotubes Nature 372 159 Occurrence Handle10.1038/372159a0 Occurrence Handle1:CAS:528:DyaK2MXitV2ms7k%3D
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Li, C. Voltammetric determination of 2-chlorophenol using a glassy carbon electrode coated with multi-wall carbon nanotube-dicetyl phosphate film. Microchim Acta 157, 21–26 (2007). https://doi.org/10.1007/s00604-006-0658-y
Received:
Accepted:
Published:
Issue Date: