Skip to main content
Log in

Voltammetric determination of 2-chlorophenol using a glassy carbon electrode coated with multi-wall carbon nanotube-dicetyl phosphate film

  • Original Paper
  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract.

Multi-wall carbon nanotubes (MWNT) were dispersed into water in the presence of dicetyl phosphate (DCP), and MWNT-DCP composite film coated glassy carbon electrodes (GCE) were constructed. The electrochemical properties of 2-chlorophenol at a bare GCE and MWNT-DCP modified GCE were compared. It was found that MWNT-DCP modified GCEs significantly enhance the oxidation peak current of 2-chlorophenol and lowers its oxidation overpotential, suggesting great potential in the sensitive determination of 2-chlorophenol. Finally, a sensitive and simple voltammetric method was developed for the determination of 2-chlorophenol. The oxidation peak current increases linearly with the concentration in the range of 1.0 × 10−7–2.0 × 10−5 mol L−1, and the detection limit is 4.0 × 10−8 mol L−1 for 2 min accumulation. The method was successfully used to determine 2-chlorophenol in waste water samples.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • F B Dewalle D A Kalman R Dills D Noram E S K Chain M Giabbai M Ghosal (1982) ArticleTitlePresence of phenolic-compounds in sewage, effluent and sludge from municipal sewage-treatment plants Water Sci Technol 14 143

    Google Scholar 

  • A Dicorcia S Marchese R J Samperi (1993) ArticleTitleEvaluation of graphitized carbon-black as a selective adsorbent for extracting acidic organic-compounds from water J Chromatogr 642 163 Occurrence Handle10.1016/0021-9673(93)80084-L Occurrence Handle1:CAS:528:DyaK3sXmtlemsL4%3D

    Article  CAS  Google Scholar 

  • H Kontsas C Rosenberg P Jappinen M L Riekkola (1993) ArticleTitleGlass-fiber prefilter xad-2 sampling and gas-chromatographic determination of airborne chlorophenols J Chromatogr 636 255 Occurrence Handle10.1016/0021-9673(93)80239-5

    Article  Google Scholar 

  • I Rodriguez R Cela (1997) ArticleTitleCombination of solid-phase extraction procedures with gas chromatographic hyphenated techniques for chlorophenol determination in drinking water Trac-Trends in Anal Chem 16 463 Occurrence Handle10.1016/S0165-9936(97)00060-5 Occurrence Handle1:CAS:528:DyaK2sXmvVGmsbc%3D

    Article  CAS  Google Scholar 

  • H Kontsas C Rosenberg P Pfaffli P Jappinen (1995) ArticleTitleGas-chromatographic mass-spectrometric determination of chlorophenols in the urine of sawmill workers with past use of chlorophenol-containing antistain agents Analyst 120 1745 Occurrence Handle10.1039/an9952001745 Occurrence Handle1:CAS:528:DyaK2MXmtlOktL0%3D

    Article  CAS  Google Scholar 

  • M L Antonelli L Campanella P Ercole (2005) ArticleTitleLichen-based biosensor for the determination of benzene and 2-chlorophenol: microcalorimetric and amperometric investigations Anal Bioanal Chem 381 1041 Occurrence Handle10.1007/s00216-004-3014-2 Occurrence Handle1:CAS:528:DC%2BD2MXit1Cru7Y%3D

    Article  CAS  Google Scholar 

  • M S Ureta-Zanartu C Berrios J Pavez J Zagal C Gutierrez J F Marco (2003) ArticleTitleElectrooxidation of 2-chlorophenol on polyNiTSPc-modified glassy carbon electrodes J Electroanal Chem 553 147 Occurrence Handle10.1016/S0022-0728(03)00309-7 Occurrence Handle1:CAS:528:DC%2BD3sXmvF2ms7c%3D

    Article  CAS  Google Scholar 

  • S Iijima (1991) ArticleTitleHelical microtubules of graphite carbon Nature 354 56 Occurrence Handle10.1038/354056a0 Occurrence Handle1:CAS:528:DyaK38Xmt1Ojtg%3D%3D

    Article  CAS  Google Scholar 

  • P J Britto K S V Santhanam P M Ajayan (1996) ArticleTitleCarbon nanotube electrode for oxidation of dopamine Bioelectrochem Bioenerg 41 121 Occurrence Handle10.1016/0302-4598(96)05078-7 Occurrence Handle1:CAS:528:DyaK28Xls1Knt7k%3D

    Article  CAS  Google Scholar 

  • M Musamech J Wang A Merkoci Y H Lin (2002) ArticleTitleLow-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes Electrochem Commun 4 743 Occurrence Handle10.1016/S1388-2481(02)00451-4

    Article  Google Scholar 

  • K B Wu J J Fei S S Hu (2003) ArticleTitleSimultaneous determination of dopamine and serotonin on a glassy carbon electrode coated with a film of carbon nanotubes Anal Biochem 318 100 Occurrence Handle10.1016/S0003-2697(03)00174-X Occurrence Handle1:CAS:528:DC%2BD3sXktFWhtL4%3D

    Article  CAS  Google Scholar 

  • K B Wu S S Hu J J Fei B Wen (2003) ArticleTitleMercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-wall carbon nanotubes Anal Chim Acta 489 215 Occurrence Handle10.1016/S0003-2670(03)00718-9 Occurrence Handle1:CAS:528:DC%2BD3sXlvFGmtr0%3D

    Article  CAS  Google Scholar 

  • J Wang M Musameh Y H Lin (2003) ArticleTitleSolubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors J Am Chem Soc 125 2408 Occurrence Handle10.1021/ja028951v Occurrence Handle1:CAS:528:DC%2BD3sXpvVartA%3D%3D

    Article  CAS  Google Scholar 

  • S C Tsang Y K Chen P J E Harris M L H Green (1994) ArticleTitleA simple chemical method of opening and filling carbon nanotubes Nature 372 159 Occurrence Handle10.1038/372159a0 Occurrence Handle1:CAS:528:DyaK2MXitV2ms7k%3D

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chunya Li.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Li, C. Voltammetric determination of 2-chlorophenol using a glassy carbon electrode coated with multi-wall carbon nanotube-dicetyl phosphate film. Microchim Acta 157, 21–26 (2007). https://doi.org/10.1007/s00604-006-0658-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00604-006-0658-y

Navigation