Successful implantation of a bipolar epicardial lead and an autocapture pacemaker in a low-body-weight infant with congenital atrioventricular block: Report of a case

  • Case Reports
  • Published:
Surgery Today Aims and scope Submit manuscript

Abstract

A permanent pacemaker system was successfully implanted into a low-body-weight infant with congenital atrioventricular (AV) block, using a bipolar epicardial CapSure Epi lead and an autocaptured Pacesetter Solus-micro VVIR pacemaker. The calculated life span of the pacemaker generator is 5 years with a heart rate of 120/min and an output of 1.2 V (0.31ms), and fortunately, its threshold was autocaptured. Thus, we can conclude that the combination of a steroid-eluted bipolar epicardial lead and the smallest possible autocaptured pacemaker generator is most suitable for a neonate or young infant.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bharati S, Swerdlow MA, Vitullo D, Chiemmongkoltip P, Lev M (1987) Neonatal lupus with congenital atrioventricular block and myocarditis. PACE 10:1058–1070

    PubMed  CAS  Google Scholar 

  2. Gillette PC, Shannon C (1985) Cardiac pacing in children. In: Serge BS (ed) Modern cardiac pacing. Futura, Mount Kisco, NY, pp 483–494

    Google Scholar 

  3. Smith RT Jr, Armstrong K, Gillette PC, Garson A Jr (1987) Comparison of dual chambered endocardial and epicardial pacing systems in children (Abstract). PACE 10:441

    Google Scholar 

  4. Johns JA, Fish FFA, Burger JD, Hammon JW (1992) Steroideluting epicardial leads in pediatric patients: encouraging early results. JACC 20:395–401

    PubMed  CAS  Google Scholar 

  5. Kugler JD, Danford DA (1989) Pacemakers in children: an update. Am Heart J 117:665–679

    Article  PubMed  CAS  Google Scholar 

  6. Sermasi S, Marconi M, Libero L, Moracchini PV, Rusconi L, Mininno A, Sigliano R (1996) Italian experience with AutoCapture in conjunction with a membrane lead. Pacesetter Automatic Control of Energy and Membrane Automatic Threshold Evaluation (Pacemate) Study Group. PACE 19:1799–1804

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tomita, Y., Imoto, Y., Tominaga, R. et al. Successful implantation of a bipolar epicardial lead and an autocapture pacemaker in a low-body-weight infant with congenital atrioventricular block: Report of a case. Surg Today 30, 555–557 (2000). https://doi.org/10.1007/s005950070128

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s005950070128

Key Words

Navigation