Abstract
Purpose
Patient–prosthesis mismatch (PPM) is defined when the ratio of the effective orifice area of the normally functioning prosthetic valve to the body surface area of the patient is <0.85 cm2/m2. The aim of this study was to assess the measurements of the mean platelet volume (MPV) as an indicator of platelet activation in patients with PPM.
Methods
A total of 109 patients with isolated aortic valve replacement (AVR) procedures with a mechanical prosthesis and a control group from a normal population of 102 people compatible in terms of age and sex were chosen for the study. The AVR group was subdivided into a PPM group (n = 41) and non-PPM group (n = 68). All patients and control participants underwent echocardiographic examinations, with simultaneous measurements of the serum MPV values.
Results
The MPV measurements were significantly higher in the patients with AVR compared to the control group (8.97 ± 0.93 vs. 8.26 ± 0.14, p < 0.001). Higher results were also obtained in the patients with PPM compared to the non-PPM group (9.36 ± 0.61 vs. 8.73 ± 1.01, p < 0.001). The platelet counts were found to be similar in both groups (p > 0.05).
Conclusions
We have herein shown that the PPM patients had a significantly higher MPV compared to the patients with AVR without PPM and healthy subjects.
Similar content being viewed by others
References
Spaccarotella C, Mongiardo A, Indolfi C. Pathophysiology of aortic stenosis and approach to treatment with percutaneous valve implantation. Circ J. 2011;75:11–9.
Hara H, Schwartz RS. Transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis. Circ J. 2010;74:1513–7.
Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation. 1978;58:20–4.
Pibarot P, Dumesnil JG. The relevance of prosthesis-patient mismatch after aortic valve replacement. Nat Clin Pract Cardiovasc Med. 2008;5:764–5.
Yap CH, Mohajeri M, Yii M. Prosthesis-patient mismatch is associated with higher operative mortality following aortic valve replacement. Heart Lung Circ. 2007;16:260–4.
Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart. 2006;92:1022–9.
Dumesnil JG, Pibarot P. Prosthesis-patient mismatch and clinical outcomes: the evidence continues to accumulate. J Thorac Cardiovasc Surg. 2006;131:952–5.
Chafizadeh ER, Zoghbi WA. Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation. Circulation. 1991;83:213–23.
Pibarot P, Dumesnil JG, Lemieux M, Cartier P, Métras J, Durand LG. Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity and mortality after aortic valve replacement with a bioprosthetic heart valve. J Heart Valve Dis. 1998;7:211–8.
Metren M, Chow T, Hellums JD, Thiagarajan P. A new role for P-selectin in shear induced platelet aggregation. Circulation. 2000;102:2045–50.
Park Y, Schoene N, Haris W. Mean platelet volume as an indicator of platelet activation: methodological issues. Platelets. 2002;13:301–6.
Martin JF, Trowbridge EA, Salmon GL, Plumb J. The biological significance of platelet volume: its relationship to bleeding time, platelet thromboxane B2 production and megakaryocyte nuclear DNA concentration. Thromb Res. 1983;32:443–60.
Jakubowski JA, Thompson CB, Vaillancourt R, Valeri CR, Deykin D. Arachidonic acid metabolism by platelets of differing size. Br J Haematol. 1983;53:503–11.
Varol E, Arslan A, Yucel H, Ozaydın M, Erdogan D, Dogan A. Increased mean platelet volume in patients with aortic stenosis. Clin Appl Thromb Hemost. 2011;6:17–20.
Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr. 1989;2:358–67.
Blais C, Dumesnil JG, Baillot R, Simard S, Doyle D, Pibarot P. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation. 2003;108:983–8.
Mohty D, Malouf JF, Girard SE, Schaff HV, Grill DE, Enriquez-Sarano ME, et al. Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position. Circulation. 2006;113:420–6.
Penny WF, Weinstein M, Salzman EW, Ware JA. Correlation of circulating von Willebrand factor levels with cardiovascular hemodynamics. Circulation. 1991;83:1630–6.
Miceli A, Gilmanov D, Murzi M, Parri MS, Cerillo AG, Bevilacqua S, et al. Evaluation of platelet count after isolated biological aortic valve replacement with Freedom Solo bioprosthesis. Eur J Cardiothorac Surg. 2012;41:69–73.
Leguyader A, Watanabe R, Berbé J, Boumediene A, Cogné M, Laskar M. Platelet activation after aortic prosthetic valve surgery. Interact Cardiovasc Thorac Surg. 2006;5:60–4.
Kamath S, Blann AD, Lip GY. Platelet activation: assessment and quantification. Eur Heart J. 2001;22:1561–71.
Robicsek F, Thubrikar MJ, Cook JW. The congenital bicuspid aortic valve: how does it function? Why does it fail. Ann Thorac Surg. 2004;77:177–85.
Conflict of interest
Huseyin Bayram and the co-authors have no conflicts of interest to declare.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bayram, H., Hidiroglu, M., Cetin, L. et al. Patient–prosthesis mismatch increases the mean platelet volume in patients with aortic valve replacement. Surg Today 45, 559–563 (2015). https://doi.org/10.1007/s00595-014-0933-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00595-014-0933-1