Skip to main content

Advertisement

Log in

The EMS stress view: occult pelvic instability revealed by pre-hospital pelvic binder placement

  • Original Article
  • Published:
European Journal of Orthopaedic Surgery & Traumatology Aims and scope Submit manuscript

Abstract

Purpose

To describe and evaluate the serendipitous pelvic binder stress radiographs of lateral compression type (LC) pelvic ring injuries.

Methods

This was a retrospective case series performed at a single, level I academic trauma center from 2016 to 2018. All patients presenting with a minimally displaced LC pelvic ring injury were reviewed (< 10 cm displacement on static pelvic radiographs). Patients with X-rays (XR) in a pelvic binder (EMS stress) and with the pelvic binder removed were included. Pelvic ring stability was determined by attending surgeon evaluation of EMS stress radiographs versus static XR of the pelvis. Patients were treated non-operatively and allowed to weight bear or taken to the operating room for exam under anesthesia (EUA) and potential operative fixation. Clinical success of treatment was determined by evaluation of further displacement at the completion of their most recent follow-up.

Results

Thirty-seven patients of the initial 398 reviewed met inclusion criteria. Fourteen of 37 patients (38%) were categorized as stable with no significant pelvis displacement seen on EMS stress and were treated non-operatively without further sequelae (4.6 months mean follow-up). The remaining 23/37 (62%) were treated operatively. Occult instability was identified on EMS stress in 14 (61%) of those 23 patients and the remainder were determined to be unstable based upon fracture pattern or EUA. All patients went on to successful treatment without significant pelvic deformity (7.8 months mean follow-up).

Conclusion

The EMS stress XR is a valuable, opportunistic evaluation in LC pelvic ring injuries. This evaluation is a useful diagnostic adjunct to alert the provider that additional stress imaging may be indicated to evaluate for occult pelvic ring instability.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Costantini TW, Coimbra R, Holcomb JB, Podbielski JM, Catalano R, Blackburn A, Scalea TM, Stein DM, Williams L, Conflitti J, Keeney S, Suleiman G, Zhou T, Sperry J, Skiada D, Inaba K, Williams BH, Minei JP, Privette A, Mackersie RC, Robinson BR, Moore FO (2016) Group APFS current management of hemorrhage from severe pelvic fractures: results of an American association for the surgery of trauma multi-institutional trial. J Trauma Acute Care Surg 80(5):717–723. https://doi.org/10.1097/TA.0000000000001034

    Article  CAS  PubMed  Google Scholar 

  2. Routt ML Jr, Falicov A, Woodhouse E, Schildhauer TA (2002) Circumferential pelvic antishock sheeting: a temporary resuscitation aid. J Orthop Trauma 16(1):45–48

    Article  PubMed  Google Scholar 

  3. Bottlang M, Krieg JC, Mohr M, Simpson TS, Madey SM (2002) Emergent management of pelvic ring fractures with use of circumferential compression. J Bone Jt Surg Am 84(Suppl 2):43–47

    Article  Google Scholar 

  4. Croce MA, Magnotti LJ, Savage SA, Wood GW 2nd, Fabian TC (2007) Emergent pelvic fixation in patients with exsanguinating pelvic fractures. J Am Coll Surg 204(5):935–939. https://doi.org/10.1016/j.jamcollsurg.2007.01.059

    Article  PubMed  Google Scholar 

  5. Sagi HC, Coniglione FM, Stanford JH (2011) Examination under anesthetic for occult pelvic ring instability. J Orthop Trauma 25(9):529–536. https://doi.org/10.1097/BOT.0b013e31822b02ae

    Article  PubMed  Google Scholar 

  6. Siegel J, Templeman DC, Tornetta P 3rd (2008) Single-leg-stance radiographs in the diagnosis of pelvic instability. J Bone Jt Surg Am 90(10):2119–2125. https://doi.org/10.2106/JBJS.G.01559

    Article  Google Scholar 

  7. DeKeyser GJ, Kellam PJ, Haller JM, Higgins TF, Marchand LS, Rothberg DL (2022) Emergency department stress radiographs of lateral compression type-1 pelvic ring injuries are safe, effective, and reliable. J Bone Jt Surg Am 104(4):336–344. https://doi.org/10.2106/jbjs.21.00737

    Article  Google Scholar 

  8. Parry JA, Salameh M, Maher MH, Stacey SC, Mauffrey C (2020) The lateral stress radiograph identifies occult instability of lateral compression pelvic ring injuries without sedation. J Orthop Trauma 34(11):567–571. https://doi.org/10.1097/bot.0000000000001805

    Article  PubMed  Google Scholar 

  9. Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF (2018) Fracture and dislocation classification compendium—2018. J Orthop Trauma 32(Suppl 1):S1–S170. https://doi.org/10.1097/BOT.0000000000001063

    Article  PubMed  Google Scholar 

  10. Sembler Soles GL, Lien J, Tornetta P 3rd (2012) Nonoperative immediate weightbearing of minimally displaced lateral compression sacral fractures does not result in displacement. J Orthop Trauma 26(10):563–567. https://doi.org/10.1097/BOT.0b013e318251217b

    Article  PubMed  Google Scholar 

  11. Bruce B, Reilly M, Sims S (2011) OTA highlight paper predicting future displacement of nonoperatively managed lateral compression sacral fractures: can it be done? J Orthop Trauma 25(9):523–527. https://doi.org/10.1097/BOT.0b013e3181f8be33

    Article  PubMed  Google Scholar 

  12. Hagen J, Castillo R, Dubina A, Gaski G, Manson TT, O’Toole RV (2016) Does surgical stabilization of lateral compression-type pelvic ring fractures decrease patients’ pain, reduce narcotic use, and improve mobilization? Clin Orthop Relat Res 474(6):1422–1429. https://doi.org/10.1007/s11999-015-4525-1

    Article  PubMed  Google Scholar 

  13. Gardner MJ, Krieg JC, Simpson TS, Bottlang M (2010) Displacement after simulated pelvic ring injuries: a cadaveric model of recoil. J Trauma 68(1):159–165. https://doi.org/10.1097/TA.0b013e31819adae2

    Article  PubMed  Google Scholar 

  14. Bonner TJ, Eardley WG, Newell N, Masouros S, Matthews JJ, Gibb I, Clasper JC (2011) Accurate placement of a pelvic binder improves reduction of unstable fractures of the pelvic ring. J Bone Jt Surg Br 93(11):1524–1528. https://doi.org/10.1302/0301-620X.93B11.27023

    Article  CAS  Google Scholar 

  15. Knops SP, van Riel MP, Goossens RH, van Lieshout EM, Patka P, Schipper IB (2010) Measurements of the exerted pressure by pelvic circumferential compression devices. Open Orthop J 4:101–106. https://doi.org/10.2174/1874325001004020101

    Article  PubMed  PubMed Central  Google Scholar 

  16. Gibson PD, Adams MR, Koury KL, Shaath MK, Sirkin MS, Reilly MC (2016) Inadvertent reduction of symphyseal diastasis during computed tomography. J Orthop Trauma 30(9):474–478. https://doi.org/10.1097/BOT.0000000000000627

    Article  PubMed  Google Scholar 

  17. Barei DP, Shafer BL, Beingessner DM, Gardner MJ, Nork SE, Routt ML (2010) The impact of open reduction internal fixation on acute pain management in unstable pelvic ring injuries. J Trauma 68(4):949–953. https://doi.org/10.1097/TA.0b013e3181af69be

    Article  PubMed  Google Scholar 

  18. Tornetta P 3rd, Lowe JA, Agel J, Mullis BH, Jones CB, Teague D, Kempton L, Brown K, Friess D, Miller AN, Spitler CA, Kubiak E, Gary JL, Leighton R, Morshed S, Vallier HA (2019) Does operative intervention provide early pain relief for patients with unilateral sacral fractures and minimal or no displacement? J Orthop Trauma 33(12):614–618. https://doi.org/10.1097/BOT.0000000000001578

    Article  PubMed  Google Scholar 

  19. Vallier HA, Lowe JA, Agel J, Mullis BH, Jones CB, Teague D, Kempton L, Miller AN, Spitler CA, Kubiak E, Routt MLC, Leighton R, Morshed S, Tornetta P 3rd (2019) Surgery for unilateral sacral fractures: are the indications clear? J Orthop Trauma 33(12):619–625. https://doi.org/10.1097/BOT.0000000000001587

    Article  PubMed  Google Scholar 

  20. Knops SP, Van Lieshout EM, Spanjersberg WR, Patka P, Schipper IB (2011) Randomised clinical trial comparing pressure characteristics of pelvic circumferential compression devices in healthy volunteers. Injury 42(10):1020–1026. https://doi.org/10.1016/j.injury.2010.09.011

    Article  PubMed  Google Scholar 

  21. Morris R, Loftus A, Friedmann Y, Parker P, Pallister I (2017) Intra-pelvic pressure changes after pelvic fracture: a cadaveric study quantifying the effect of a pelvic binder and limb bandaging over a bolster. Injury 48(4):833–840. https://doi.org/10.1016/j.injury.2017.01.046

    Article  PubMed  Google Scholar 

Download references

Funding

The authors received no financial support for the research, authorship, and/or publication of this article.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Conor P. Kleweno.

Ethics declarations

Conflict of interest

No conflicts of interest relevant to this article.

Ethical approval

The research conducted in this study was approved by Institutional Review Board and is in compliance with local ethical standards of care.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

DeKeyser, G.J., Taylor, M.A., Allen, J.D. et al. The EMS stress view: occult pelvic instability revealed by pre-hospital pelvic binder placement. Eur J Orthop Surg Traumatol (2023). https://doi.org/10.1007/s00590-023-03601-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s00590-023-03601-2

Keywords

Navigation