Abstract
Although a C1–C2 transarticular screw (TAS) or a C2 pedicle screw (PS) is the most rigid anchor for C2, each entails the risk of vertebral artery injury. Although a C2 laminar screw (LS) is often used as an alternative anchor in such cases, its anchoring strength may be inadequate. We introduce a technical tip, in which a C2 LS is reinforced by a C2 infralaminar hook without extending the fusion range. Six patients, for whom a unilateral TAS or C2 PS was risky or impossible, were treated with O-C2 fusion using this technique. The post-operative course of each patient was uneventful. Bone union was achieved in all patients, except one who died of indifferent disease before the confirmation of bone union by computed tomography. This method would be a safe and non-technical-demanding option when the placement of a TAS or PS is risky or impossible.
Similar content being viewed by others
References
Melcher RP, Puttlitz CM, Kleinstueck FS, Lotz JC, Harms J, Bradford DS (2002) Biomechanical testing of posterior atlantoaxial fixation techniques. Spine 27:2435–2440
Neo M, Matsushita M, Iwashita Y, Yasuda T, Sakamoto T, Nakamura T (2003) Atlantoaxial transarticular screw fixation for a high-riding vertebral artery. Spine 28:666–670
Neo M, Sakamoto T, Fujibayashi S, Nakmaura T (2005) The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine 30:2800–2805
Yoshida M, Neo M, Fujibayashi S, Nakmaura T (2006) Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Spine 31:E513–E517
Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158–162
Wright NM (2005) Translaminar rigid screw fixation of axis. Technical note. J Neurosurg 3:409–414
Ma W, Feng L, Xu R, Liu X, Lee AH, Sun S, Zhao L, Hu Y, Liu G (2010) Clinical application of C2 laminar screw technique. Eur Spine J 19:1312–1317
Lehman RA, Dmitriev AE, Helgeson MD, Sasso RC, Kuklo TR, Riew KD (2008) Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine 20:960–965
Claybrooks R, Kayanja M, Milks R, Benzel E (2007) Atlantoaxial fusion: a biomechanical analysis of two C1–C2 fusion techniques. Spine J 7:682–688
Hong JT, Takigawa T, Udayakunmar R, Shin HK, Simon P, Espinoza Orías AA, Inoue N, An HS (2011) Biomechanical effect of the C2 laminar decortication on the stability of C2 intralaminar screw construct and biomechanical comparison of C2 intralaminar screw and C2 pars screw. Neurosurgery 69(1 Suppl Operative):ons 1–6
Yoshitomi H, Neo M, Ito H, Takemoto M, Masaski Y, Nakamura T (2011) Doppler ultrasonography and computed tomography angiography demonstrate positional occlusion of vertebral artery associated with one-sided destruction of the atlantoaxial lateral mass caused by rheumatoid arthritis: a case report. Spine 36:E1493–E1496
Chiba M, McLain RF, Yerby SA, Moseley TA, Smith TS, Benson DR (1996) Short-segment pedicle instrumentation: biomechanical analysis of supplemental hook fixation. Spine 21:288–294
Sun E, Alkalay R, Vader D, Snyder BD (2009) Preventing distal pullout of posterior spine instrumentation in thoracic hyperkyphosis. A biomechanical analysis. J Spinal Disord Tech 22:270–277
Hasegawa K, Takahashi HE, Uchiyama S, Hirano T, Hara T, Washino T, Sugiura T, Youkaichiya M, Ikeda M (1997) An experimental study of a combination method using a pedicle screw and laminar hook for the osteoporotic spine. Spine 22:958–962
Miyata M, Neo M, Ito H, Yoshida M, Miyaki K, Fujibayashi S, Nakayama T, Nakamura T (2008) Is rheumatoid arthritis a risk factor for a high-riding vertebral artery? Spine 33:2007–2011
Miyata M, Neo M, Ito H, Yoshida M, Fujibayashi S, Nakamura T (2008) Rheumatoid arthritis as a risk factor for a narrow C-2 pedicle: 3D analysis of the C-2 pedicle screw trajectory. J Neutrosurg Spine 9:17–21
Paxinos O, Tsitsopoulos PP, Zindrick MR, Voronov LI, Lorenz MA, Havey RM, Patwardhan AG (2010) Evaluation of pullout strength and failure mechanism of posterior instrumentation in normal and osteopenic thoracic vertebrae. J Neurosurg Spine 13:469–476
Conflict of interest
The authors declare that they have no conflict of interest. The authors declare that the study complies with the current laws of the country in which they were performed.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Neo, M., Yoshitomi, H., Takemoto, M. et al. The reinforcement of a C2 laminar screw by a C2 laminar hook as an anchor of occipito-C2 fusion. Eur J Orthop Surg Traumatol 24, 635–639 (2014). https://doi.org/10.1007/s00590-013-1349-0
Received:
Accepted:
Published:
Issue Date: