Skip to main content

Advertisement

Log in

The intramedullary Endobutton® technique: the outcome of repair of acute distal biceps rupture

  • Original Article
  • Published:
European Journal of Orthopaedic Surgery & Traumatology Aims and scope Submit manuscript

Abstract

In this paper, we seek to present the outcome of repair of acute distal biceps tendon rupture using the intramedullary Endobutton® technique. We retrospectively assessed all patients undergoing repair of a distal biceps tendon rupture using a new technique with a single incision volar approach and repair with an Endobutton inserted into the intramedullary canal. Seven patients were included in the study. Patients were assessed clinically and also with dynamometry. All of the patients were male and had a mean age 49. On dynamometry assessment: the mean difference in power between arms on flexion/extension post-operatively was a reduction of 3% in the affected arm and the mean difference in work over a 60-s period was unchanged. There was no significant difference in post-op range of motion in the operated arm when compared to the unaffected side. No complications were identified. The results obtained in this study demonstrate a good short-term functional outcome with this technique.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Baker BE, Bierwagen D (1985) Rupture of the distal tendon of the biceps brachii: operative versus non-operative treatment. J Bone Joint Surg 67A:414–417

    Google Scholar 

  2. Bain GI, Prem H, Heptinstall RJ, Verhellen R, Paix D (2000) Repair of distal biceps tendon rupture: a new technique using the Endobutton. J Shoulder Elbow Surg 9(2):120–126

    Article  PubMed  CAS  Google Scholar 

  3. Davison BL, Engber WD, Tigert LJ (1996) Long term evaluation of repaired distal biceps brachii tendon ruptures. Clin Orthop Relat Res Dec, (333), 186–191

  4. Lynch SA, Beard DA, Renstrom PA (1999) Repair of distal biceps tendon rupture with suture anchors. Knee Surg Sports Traumatol Arthroscop 7(2):125–131

    Article  CAS  Google Scholar 

  5. Catonne Y, Delattre O, Pascal-Mousselard H, d’Istria FC, Busson J, Rouvillain JL (1995) Rupture of the distal tendon of the biceps brachialis: apropos of 43 cases. Rev Chir Orthop Reparatrice Appar Mot 81(2):163–172

    PubMed  CAS  Google Scholar 

  6. Kelly EW, Morrey BF, O’Driscoll SW (2000) Complications of repair of the distal biceps tendon with the modified two-incision technique. J Bone Joint Surg Am 82-A(11):1575–1581

    PubMed  CAS  Google Scholar 

  7. Moosmayer S, Odinsson A, Holm I (2000) Distal biceps tendon rupture operated on with the Boyd-Anderson technique: follow-up of 9 patients with isokinetic examination after 1 year. Acta Orthop Scand 71(4):399–402

    Article  PubMed  CAS  Google Scholar 

  8. Lintner S, Fischer T (1996) Repair of the distal biceps tendon using suture anchors and an anterior approach. Clin Orthop Relat Res (322):116–119

  9. Strauch RJ, Michelson H, Rosenwasser MP (1997) Repair of rupture of the distal tendon of the biceps brachii. Review of the literature and report of three cases treated with a single anterior incision and suture anchors. Am J Orthop 26(2):151–156

    PubMed  CAS  Google Scholar 

  10. Greenberg JA, Fernandez JJ, Wang T, Turner C (2003) EndoButton-assisted repair of distal biceps tendon ruptures. J Shoulder Elbow Surg 12(5): 484–490 (Erratum in J Shoulder Elbow Surg 14(2): 231, 2005)

    Google Scholar 

  11. Sharma S, Mackay G (2005) Endoscopic repair of distal biceps tendon using an EndoButton. Arthroscopy 21(7):897

    Article  PubMed  Google Scholar 

Download references

Conflict of interest statement

The authors received financial assistance totaling less than £1,000 for carrying out of this study from a commercial party (Smith and Nephew).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to James E. Arbuthnot.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Arbuthnot, J.E., Deans, V.M., Morgan, D. et al. The intramedullary Endobutton® technique: the outcome of repair of acute distal biceps rupture. Eur J Orthop Surg Traumatol 19, 155–157 (2009). https://doi.org/10.1007/s00590-008-0403-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00590-008-0403-9

Keywords

Navigation