Advertisement

Subcutaneous injection of mercury and extensor tendon rupture from a broken thermometer

  • Panagiotis G. Ntagiopoulos
  • Andreas F. Mavrogenis
  • Ioannis S. Benetos
  • Panayiotis J. Papagelopoulos
  • Demetrios S. KorresEmail author
  • Panayotis N. Soucacos
Case Report

Abstract

A 28-year old medical doctor presented with a hand injury caused by a broken mercury thermometer .The extensor digiti minimi tendon was ruptured. Operative treatment included debridement and removal of the mercury followed by repair of the tendon. Reoperation was required to excise wound granulomatous reaction from residual droplets of mercury. There were no signs and symptoms of mercury intoxication. To prevent mercury intoxication after subcutaneous metallic mercury injection, complete surgical removal of the mercury and serial monitoring of blood and urine mercury concentrations is mandatory.

Keywords

Mercury Subcutaneous injection Tendon rupture Intoxication Surgical treatment 

Mots clés

Mercure Injection sous-cutanée Rupture de tendon Intoxication Traitement chirurgical 

Injection sous-cutanée de mercure et rupture de tendon extenseur par un thermomètre cassé

Résumé

Le cas d’un médecin âgé de 28 ans avec des lésions de la main par un thermomètre de mercure cassé est présenté. Le tendon du court extenseur des doigts avait été rompu. Le débridement et l’ablation des gouttelettes de mercure ont été suivies par la réparation tendineuse. Une réintervention a été nécessaire pour exciser du tissu granulomateux formé autour des gouttelettes résiduelles de mercure. Il n’y avait aucun signe et symptôme d’intoxication de mercure. Pour empêcher l’intoxication de mercure après injection métallique sous-cutanée de mercure, l’ablation chirurgicale complète du mercure et la surveillance périodique des concentrations en mercure de sang et d’urine est obligatoire.

References

  1. 1.
    Boyd A, Seger D, Vannucci S, Langley M, Abraham JL, King LE Jr (2000) Mercury exposure and cutaneous disease. J Am Acad Dermatol 43(1):81–90CrossRefPubMedGoogle Scholar
  2. 2.
    Bradberry SM, Feldman MA, Braithwaite RA, Shortland-Webb W, Vale JA (1996) Elemental mercury-induced skin granuloma: a case report and review of the literature. J Toxicol Clin Toxicol 34(2):209–216PubMedCrossRefGoogle Scholar
  3. 3.
    Ellaban MG, Ali R, Hart NB (2003) Subcutaneous metallic mercury injection of the hand. Br J Plast Surg 56:47–49CrossRefPubMedGoogle Scholar
  4. 4.
    Graeme KA, Pollack CV (1998) Heavy metal toxicity, Part I: arsenic and mercury. J Emerg Med 16:45–56CrossRefPubMedGoogle Scholar
  5. 5.
    Isik S, Guler M, Ozturk S, Selmanpakoglu N (1997) Subcutaneous metallic mercury injection: early, massive excision. Ann Plast Surg 38(6):645–648PubMedCrossRefGoogle Scholar
  6. 6.
    Maynou C, Mathieu-Nolf M, Mestdagh H, Gillas-Buron G (2000) Accidental subcutaneous injection of elemental mercury. A case report. Acta Orthop Belg 66(3):292–296Google Scholar
  7. 7.
    Souza EM, Cintra ML, Melo VG, Vieira RJ, De Capitani EM, Zambrone FA (2000) Subcutaneous injection of elemental mercury with distant skin lesions. J Toxicol Clin Toxicol 38(4):441–443CrossRefPubMedGoogle Scholar
  8. 8.
    Theodorou SD, Vlachos P, Vamvasakis E (1981) Knee joint injury by mercury from a broken thermometer. Clin Orthop 160:159–162PubMedGoogle Scholar
  9. 9.
    Yotsuyanagi T, Yokoi K, Sawada Y (1996) Facial injury from a broken thermometer. J Trauma 40(5):847–849PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag 2006

Authors and Affiliations

  • Panagiotis G. Ntagiopoulos
    • 1
  • Andreas F. Mavrogenis
    • 1
  • Ioannis S. Benetos
    • 1
  • Panayiotis J. Papagelopoulos
    • 1
  • Demetrios S. Korres
    • 1
    • 2
    Email author
  • Panayotis N. Soucacos
    • 1
  1. 1.Department of OrthopaedicsAthens University Medical SchoolAthensGreece
  2. 2.AthensGreece

Personalised recommendations