Skip to main content

Advertisement

Log in

Learning curve of junior surgeons in robot-assisted pedicle screw placement: a comparative cohort study

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Objective

Robot-assisted technology has been gradually applied to pedicle screw placement in spinal surgery. This study was designed to detailedly evaluate the learning curve of junior surgeons in robot-assisted spine surgery.

Methods

From December 2020 to February 2022, 199 patients requiring surgical treatment with posterior pedicle screw fixation were prospectively recruited into the study. The patients were randomized to the robot-assisted group (the RA group) or the conventional freehand group (the CF group). Under the senior specialist’s supervision, pedicle screws were placed by two junior fellows without prior experience. Cumulative summation (CUSUM) analysis was performed on the learning curve of pedicle screw placement for performing quantitative assessment based on the time of screw insertion.

Results

In total, 769 and 788 pedicle screws were placed in the RA and CF groups. Compared with the CF group, the learning duration in the RA group was shorter in the upper thoracic region (57 vs. 70 screws), but longer in the lower thoracic (62 vs. 58 screws) and the lumbosacral region (56 vs. 48 screws). The slope of learning curve was lower in the RA group than in the CF group. The screw accuracy in the RA group was superior to that in the CF group, especially in upper thoracic region (89.4% vs. 76.7%, P < 0.001). This disparity of accuracy became wider in deformity cases. In the upper thoracic region, the mean placement time was 5.34 ± 1.96 min in the RA group and 5.52 ± 2.43 min in the CF groups, while in the lower thoracic and lumbosacral regions, the CF group's mean placement times were statistically shorter. Three screw-related neural complications occurred in the CF group.

Conclusion

Robot-assisted technique has its advantages in the upper thoracic region and deformity cases, which is easier and safer to insert pedicle screws. The robot-assisted technique allowed a short learning curve for junior surgeons and exhibited consistently excellent results even in the early application period.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

References

  1. Bäcker HC, Freibott CE, Perka C, Weidenbaum M (2020) Surgeons’ learning curve of renaissance robotic surgical system. Int J spine Surg 14:818–823

    Article  PubMed  PubMed Central  Google Scholar 

  2. Hu X, Lieberman IH (2014) What is the learning curve for robotic-assisted pedicle screw placement in spine surgery? Clin Orthop Relat Res 472:1839–1844

    Article  PubMed  Google Scholar 

  3. Urakov TM, Chang KH, Burks SS, Wang MY (2017) Initial academic experience and learning curve with robotic spine instrumentation. Neurosurg Focus 42:E4

    Article  PubMed  Google Scholar 

  4. Hyun SJ, Kim KJ, Jahng TA, Kim HJ (2017) Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial. Spine 42:353–358

    Article  PubMed  Google Scholar 

  5. Pennington Z, Judy BF, Zakaria HM et al (2022) Learning curves in robot-assisted spine surgery: a systematic review and proposal of application to residency curricula. Neurosurg Focus 52:E3

    Article  PubMed  Google Scholar 

  6. Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342 (discussion 42)

    Article  PubMed  Google Scholar 

  7. Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14

    Article  CAS  PubMed  Google Scholar 

  8. Bokhari MB, Patel CB, Ramos-Valadez DI, Ragupathi M, Haas EM (2011) Learning curve for robotic-assisted laparoscopic colorectal surgery. Surg Endosc 25:855–860

    Article  PubMed  Google Scholar 

  9. Wohl H (1977) The cusum plot: its utility in the analysis of clinical data. N Engl J Med 296:1044–1045

    Article  CAS  PubMed  Google Scholar 

  10. Morse KW, Heath M, Avrumova F, et al. (2021) Comprehensive error analysis for robotic-assisted placement of pedicle screws in pediatric spinal deformity: the initial learning curve. J Pediatr Orthop 41:E524–E532

  11. Khan A, Meyers JE, Siasios I, Pollina J (2019) Next-generation robotic spine surgery: first report on feasibility, safety, and learning curve. Oper Neurosurg (Hagerstown, Md.) 17:61–69

    Article  Google Scholar 

  12. Molliqaj G, Schatlo B, Alaid A et al (2017) Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery. Neurosurg Focus 42:E14

    Article  PubMed  Google Scholar 

  13. Kim HJ, Lee SH, Chang BS et al (2015) Monitoring the quality of robot-assisted pedicle screw fixation in the lumbar spine by using a cumulative summation test. Spine 40:87–94

    Article  PubMed  Google Scholar 

  14. Avrumova F, Morse KW, Heath M, Widmann RF, Lebl DR (2021) Evaluation of K-wireless robotic and navigation assisted pedicle screw placement in adult degenerative spinal surgery: learning curve and technical notes. J Spine Surg (Hong Kong) 7:141–154

    Article  Google Scholar 

  15. Chaput de Saintonge DM, Vere DW (1974) Why don’t doctors use cusums? Lancet (London, England) 1:120–121

    Article  CAS  PubMed  Google Scholar 

  16. Siddiqui MI, Wallace DJ, Salazar LM, Vardiman AB (2019) Robot-assisted pedicle screw placement: learning curve experience. World Neurosurg 130:e417–e422

    Article  PubMed  Google Scholar 

  17. Song G, Sun X, Miao S et al (2019) Learning curve for robot-assisted lobectomy of lung cancer. J Thorac Dis 11:2431–2437

    Article  PubMed  PubMed Central  Google Scholar 

  18. Vaccaro AR, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg. Am Vol 77:1193–1199

    Article  CAS  Google Scholar 

  19. Ebraheim NA, Xu R, Ahmad M, Yeasting RA (1997) Projection of the thoracic pedicle and its morphometric analysis. Spine 22:233–238

    Article  CAS  PubMed  Google Scholar 

  20. Samdani AF, Ranade A, Sciubba DM et al (2010) Accuracy of free-hand placement of thoracic pedicle screws in adolescent idiopathic scoliosis: How much of a difference does surgeon experience make? Eur Spine J: Offic Publ Eur Spine Soc, Eur Spinal Deform Soc, Eur Sect Cerv Spine Res Soc 19:91–95

    Article  Google Scholar 

  21. Guzey FK, Emel E, Hakan Seyithanoglu M et al (2006) Accuracy of pedicle screw placement for upper and middle thoracic pathologies without coronal plane spinal deformity using conventional methods. J Spinal Disord Tech 19:436–441

    Article  PubMed  Google Scholar 

  22. Schizas C, Theumann N, Kosmopoulos V (2007) Inserting pedicle screws in the upper thoracic spine without the use of fluoroscopy or image guidance. Is it safe? Eur Spine J: Offic Publ Eur Spine Soc, Eur Spinal Deform Soc, Eur Sect Cerv Spine Res Soc 16:625–629

    Article  Google Scholar 

  23. Yu J, Zhang Q, Fan MX, Han XG, Liu B, Tian W (2021) Learning curves of robot-assisted pedicle screw fixations based on the cumulative sum test. World J Clin Cases 9:10134–10142

    Article  PubMed  PubMed Central  Google Scholar 

  24. Li HM, Zhang RJ, Shen CL (2020) Accuracy of pedicle screw placement and clinical outcomes of robot-assisted technique versus conventional freehand technique in spine surgery from nine randomized controlled trials: a meta-analysis. Spine 45:E111–E119

    Article  PubMed  Google Scholar 

  25. Lieberman IH, Hardenbrook MA, Wang JC, Guyer RD (2012) Assessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system. J Spinal Disord Tech 25:241–248

    Article  PubMed  Google Scholar 

  26. Roser F, Tatagiba M, Maier G (2013) Spinal robotics: current applications and future perspectives. Neurosurgery 72(Suppl 1):12–18

    Article  PubMed  Google Scholar 

  27. Lee NJ, Buchanan IA, Zuckermann SL et al (2022) What is the comparison in robot time per screw, radiation exposure, robot abandonment, screw accuracy, and clinical outcomes between percutaneous and open robot-assisted short lumbar fusion?: A multicenter, propensity-matched analysis of 310 patients. Spine 47:42–48

    Article  PubMed  Google Scholar 

Download references

Funding

This work was supported by the grants from National Natural Science Foundation (81802216, 82072418) and Shanghai Science and Technology Fund (20DZ2201300).

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Lifeng Lao or Hongxing Shen.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval and consent to participate

This study was performed in line with the principles of the Declaration of Helsinki and STROCSS 2019 Guideline. Ethics approval was obtained from the Institutional Review Board of Renji Hospital, School of Medicine, Shanghai Jiao Tong University. Informed consent was obtained from all individual participants included in the study. This study was relevant to the study registered at chictr.org.cn (Number: ChiCTR2000040555).

Consent for publication

Not applicable.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Fan Feng and Xiuyuan Chen are contributed equally to this work.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Feng, F., Chen, X., Liu, Z. et al. Learning curve of junior surgeons in robot-assisted pedicle screw placement: a comparative cohort study. Eur Spine J 33, 314–323 (2024). https://doi.org/10.1007/s00586-023-08019-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-023-08019-2

Keywords

Navigation