Abstract
Purpose
To describe the safety and feasibility of C2 medial window screw (C2MWS) as an alternative salvage method for C2 pedicle screws in cases of high-riding vertebral artery (HRVA) or narrow pedicle.
Methods
The C2MWS technique involves screw insertion by intentionally breaching the medial cortex of the pedicle to avoid vertebral artery injury. Twelve patients who underwent C2 screw insertion via the C2MWS were retrospectively reviewed. C2MWS was indicated in cases of high-riding vertebral artery (HRVA) or narrow pedicle (pedicle width ≤ 4 mm). The width of the canal breach by screw, vertebral artery groove (VAG) breach, solid fusion, neck pain visual analogue scale (VAS) score, and Japanese Orthopedic Association (JOA) score were assessed as outcome measurements.
Results
C2MWS was indicated due to both HRVA and narrow pedicle for 11 screws, narrow pedicle for one screw, and HRVA for two screws. No screw VAG breach or vertebral artery injury was noted postoperatively. The mean width of canal breach was 2.9 ± 1.3 mm. There were no cases demonstrating neurologic deterioration, and 11 patients (91.7%) demonstrated solid fusion at 1-year follow-up. Furthermore, neck pain VAS and JOA scores significantly improved after the surgery.
Conclusions
The C2MWS technique can provide 3-column fixation while reliably avoiding VA injury. C2MWS could be considered as a salvage alternative method when the insertion of C2 pedicle screw is complicated by HRVA or a narrow pedicle, while there is a need to provide firmer fixation strength than that provided by pars or translaminar screws.
Level of evidence
4
Similar content being viewed by others
References
Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51:1351–1356 (Discussion 1356–1357)
Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471. https://doi.org/10.1097/00007632-200111150-00014
Punyarat P, Buchowski JM, Klawson BT, Peters C, Lertudomphonwanit T, Riew KD (2018) Freehand technique for C2 pedicle and pars screw placement: is it safe? Spine J 18:1197–1203. https://doi.org/10.1016/j.spinee.2017.11.010
Huang DG, Hao DJ, He BR, Wu QN, Liu TJ, Wang XD, Guo H, Fang XY (2015) Posterior atlantoaxial fixation: a review of all techniques. Spine J 15:2271–2281. https://doi.org/10.1016/j.spinee.2015.07.008
Du JY, Aichmair A, Kueper J, Wright T, Lebl DR (2015) Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis. J Neurosurg Spine 22:151–161. https://doi.org/10.3171/2014.10.SPINE13805
Yeom JS, Buchowski JM, Kim HJ, Chang BS, Lee CK, Riew KD (2013) Risk of vertebral artery injury: comparison between C1–C2 transarticular and C2 pedicle screws. Spine J 13:775–785. https://doi.org/10.1016/j.spinee.2013.04.005
Maki S, Koda M, Iijima Y, Furuya T, Inada T, Kamiya K, Ota M, Saito J, Okawa A, Takahashi K, Yamazaki M (2016) Medially-shifted rather than high-riding vertebral arteries preclude safe pedicle screw insertion. J Clin Neurosci 29:169–172. https://doi.org/10.1016/j.jocn.2015.11.026
Yoshida M, Neo M, Fujibayashi S, Nakamura T (2006) Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw. Spine (Phila Pa 1976) 31:E513–E517. https://doi.org/10.1097/01.brs.0000224516.29747.52
Lehman RA Jr, Dmitriev AE, Helgeson MD, Sasso RC, Kuklo TR, Riew KD (2008) Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine (Phila Pa 1976) 33:960–965. https://doi.org/10.1097/BRS.0b013e31816c915b
Dorward IG, Wright NM (2011) Seven years of experience with C2 translaminar screw fixation: clinical series and review of the literature. Neurosurgery 68:1491–1499. https://doi.org/10.1227/NEU.0b013e318212a4d7 (Discussion 1499)
Lu Y, Lee YP, Bhatia NN, Lee TQ (2019) Biomechanical comparison of C1 lateral mass-C2 short pedicle screw-C3 lateral mass screw-rod construct versus goel-harms fixation for atlantoaxial instability. Spine (Phila Pa 1976) 44:E393–E399. https://doi.org/10.1097/BRS.0000000000002868
Neo M, Matsushita M, Yasuda T, Sakamoto T, Nakamura T (2002) Use of an aiming device in posterior atlantoaxial transarticular screw fixation. Techn Note J Neurosurg 97:123–127. https://doi.org/10.3171/spi.2002.97.1.0123
Bloch O, Holly LT, Park J, Obasi C, Kim K, Johnson JP (2001) Effect of frameless stereotaxy on the accuracy of C1–2 transarticular screw placement. J Neurosurg 95:74–79. https://doi.org/10.3171/spi.2001.95.1.0074
Kim GU, Chang MC, Kim TU, Lee GW (2020) Diagnostic modality in spine disease: a review. Asian Spine J 14:910–920. https://doi.org/10.31616/asj.2020.0593
Chan AKH, Yusof MI, Abdullah MS (2021) Computed tomographic morphometric analysis of C1 and C2 for lamina cross screw placement in Malay ethnicity. Asian Spine J 15:1–8. https://doi.org/10.31616/asj.2019.0242
Kim GU, Lee GW (2020) The C2 cortical screw, an alternative fixation technique for the C2 segment during high cervical spine surgery: technical note. World Neurosurg 142:24–28. https://doi.org/10.1016/j.wneu.2020.06.160
Su BW, Shimer AL, Chinthakunta S, Salloum K, Ames CP, Vaccaro AR, Bucklen B (2014) Comparison of fatigue strength of C2 pedicle screws, C2 pars screws, and a hybrid construct in C1–C2 fixation. Spine (Phila Pa 1976) 39:E12–E19. https://doi.org/10.1097/BRS.0000000000000063
Yeom JS, Buchowski JM, Park KW, Chang BS, Lee CK, Riew KD (2008) Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement. Spine (Phila Pa 1976) 33:E942–E949. https://doi.org/10.1097/BRS.0b013e3181870441
Neo M, Matsushita M, Iwashita Y, Yasuda T, Sakamoto T, Nakamura T (2003) Atlantoaxial transarticular screw fixation for a high-riding vertebral artery. Spine (Phila Pa 1976) 28:666–670. https://doi.org/10.1097/01.BRS.0000051919.14927.57
Hlubek RJ, Bohl MA, Cole TS, Morgan CD, Xu DS, Chang SW, Turner JD, Kakarla UK (2018) Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement. Spine J 18:1374–1381. https://doi.org/10.1016/j.spinee.2017.12.003
Du YQ, Yin YH, Qiao GY, Yu XG (2020) C2 medial pedicle screw: a novel “in-out-in” technique as an alternative option for posterior C2 fixation in cases with a narrow C2 isthmus. J Neurosurg Spine. https://doi.org/10.3171/2020.2.SPINE191517
Yuan F, Yang HL, Guo KJ, Li JS, Xu K, Zhang ZM, Tang TS (2013) A clinical morphologic study of the C2 pedicle and isthmus. Eur Spine J 22:39–45. https://doi.org/10.1007/s00586-012-2417-6
Lehman RA Jr, Dmitriev AE, Wilson KW (2012) Biomechanical analysis of the C2 intralaminar fixation technique using a cross-link and offset connector for an unstable atlantoaxial joint. Spine J 12:151–156. https://doi.org/10.1016/j.spinee.2012.01.020
Kepler CC, Fang T, Bronson WH, Russo GS, Schroeder GD (2020) The C2 “parsicle” screw: introduction of a novel posterior surgical technique for upper cervical fixation. Clin Spine Surg 33:146–149. https://doi.org/10.1097/BSD.0000000000000871
Agrawal M, Devarajan LJ, Singh PK, Garg A, Kale SS (2018) Proposal of a new safety margin for placement of C2 pedicle screws on computed tomography angiography. World Neurosurg 120:e282–e289. https://doi.org/10.1016/j.wneu.2018.08.052
Jha SC, Miyazaki M, Tsumura H (2018) Kinetic change of spinal cord compression on flexion-extension magnetic resonance imaging in cervical spine. Clin Neurol Neurosurg 174:86–91. https://doi.org/10.1016/j.clineuro.2018.09.017
Bydon M, Mathios D, Macki M, De la Garza-Ramos R, Aygun N, Sciubba DM, Witham TF, Gokaslan ZL, Bydon A, Wolinksy JP (2014) Accuracy of C2 pedicle screw placement using the anatomic freehand technique. Clin Neurol Neurosurg 125:24–27. https://doi.org/10.1016/j.clineuro.2014.07.017
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Lee, DH., Park, S., Cho, J.H. et al. The medial window technique as a salvage method to insert C2 pedicle screw in the case of a high-riding vertebral artery or narrow pedicle: a technical note and case series. Eur Spine J 31, 1251–1259 (2022). https://doi.org/10.1007/s00586-022-07146-6
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00586-022-07146-6