Abstract
Purpose
In surgical correction of scoliosis with pedicle screw dual-rod systems, frequently used freehand technique of screw positioning is challenging due to 3D deformity. Screw malposition can be associated with serious complications. Image-guided technologies are already available to improve accuracy of screw positioning and decrease radiation to surgeon. This study was conducted to measure intraoperative radiation to patients in freehand technique, evaluate screw-related complications and compare radiation values to published studies using navigation techniques.
Methods
Retrospective analysis of prospectively collected data of 73 patients with idiopathic scoliosis, who underwent surgical correction with pedicle screw dual-rod system. Evaluated parameters were age, effective radiation dose (ED), fluoroscopy time, number of fused segments, correction and complications. Parameters were compared with regarding single thoracic curve (SC) and double thoracic and lumbar curves (DC), adolescent (10–18 years) or adult (> 18 years) idiopathic scoliosis, length of instrumentation. ED was compared with values for navigation from online database.
Results
Average age was 21.0 ± 9.7 years, ED was 0.17 ± 0.1 mSv, time of fluoroscopy was 24.1 ± 18.6 s, 9.5 ± 1.9 fused segments. Average correction for SC was 75.7%, for DC 69.9% (thoracic) and 76.2% (lumbar). No screw-related complications. ED was significantly lower for SC versus DC (p < 0.01), short versus long fusions (p < 0.01), no significant difference for age (p = 0.1). Published navigation data showed 6.5- to 8.8-times higher radiation exposure for patients compared to our results.
Conclusion
Compared to navigation procedures, freehanded positioning of pedicle screws in experienced hands is a safe and effective method for surgical correction of idiopathic scoliosis with a significant decrease in radiation exposure to patients.
Similar content being viewed by others
References
Patel AA, Whang PG, Vaccaro AR (2008) Overview of computer-assisted image-guided surgery of the spine. Sem Spine Surg 20(3):186–194. https://doi.org/10.1053/j.semss.2008.06.005
Prasarn ML (2014) Commentary on: intraoperative fluoroscopy, portable X-ray, and CT: patient and operating room personnel radiation exposure in spinal surgery. Spine J 14(12):2992–2994. https://doi.org/10.1016/j.spinee.2014.07.006
Wagner TA, Lai SM, Asher MA (2006) SRS surgeon members’ risk for thyroid cancer: is it increased? Paper presented at the SRS 41st annual meeting, Monterey, CA
Urbanski W, Jurasz W, Wolanczyk M, Kulej M, Morasiewicz P, Dragan SL, Zaluski R, Miekisiak G, Dragan SF (2018) Increased radiation but no benefits in pedicle screw accuracy with navigation versus a freehand technique in scoliosis surgery. Clin Orthop Relat Res 476(5):1020–1027. https://doi.org/10.1007/s11999.0000000000000204
Allam Y, Silbermann J, Riese F, Greiner-Perth R (2013) Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques. Eur Spine J 22(3):648–653. https://doi.org/10.1007/s00586-012-2505-7
Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21(2):247–255. https://doi.org/10.1007/s00586-011-2011-3
Su AW, McIntosh AL, Schueler BA, Milbrandt TA, Winkler JA, Stans AA, Larson AN (2017) How does patient radiation exposure compare with low-dose O-arm versus fluoroscopy for pedicle screw placement in idiopathic scoliosis? J Pediatr Orthop 37(3):171–177. https://doi.org/10.1097/BPO.0000000000000608
Bratschitsch G, Leitner L, Stucklschweiger G, Guss H, Sadoghi P, Puchwein P, Leithner A, Radl R (2019) Radiation exposure of patient and operating room personnel by fluoroscopy and navigation during spinal surgery. Sci Rep 9(1):17652. https://doi.org/10.1038/s41598-019-53472-z
Kobayashi K, Ando K, Ito K, Tsushima M, Morozumi M, Tanaka S, Machino M, Ota K, Ishiguro N, Imagama S (2018) Intraoperative radiation exposure in spinal scoliosis surgery for pediatric patients using the O-arm® imaging system. Eur J Orthop Surg Traumatol 28(4):579–583. https://doi.org/10.1007/s00590-018-2130-1
Suk SI (2011) Pedicle screw instrumentation for adolescent idiopathic scoliosis: the insertion technique, the fusion levels and direct vertebral rotation. Clin Orthop Surg 3(2):89–100. https://doi.org/10.4055/cios.2011.3.2.89
Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 8(77):1193–1199
Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, An HS (1995) Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment. J Bone Joint Surg Am 77(8):1200–1206
Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine (Phila Pa 1976) 29(3):33–42. https://doi.org/10.1097/01.brs.0000109983.12113.9b
Thirumala PD, Bodily L, Tint D, Ward WT, Deeney VF, Crammond DJ, Habeych ME, Balzer JR (2014) Somatosensory-evoked potential monitoring during instrumented scoliosis corrective procedures: validity revisited. Spine J 14(8):1572–1580. https://doi.org/10.1016/j.spinee.2013.09.035
Perisinakis K, Theocharopoulos N, Damilakis J, Katonis P, Papadokostakis G, Hadjipavlou A, Gourtsoyiannis N (2004) Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion. Spine (Phila Pa 1976) 29(14):1555–1560. https://doi.org/10.1097/01.brs.0000131214.57597.21
Mathews JD, Forsythe AV, Brady Z, Butler MW, Goergen SK, Byrnes GB, Giles GG, Wallace AB, Anderson PR, Guiver TA, McGale P, Cain TM, Dowty JG, Bickerstaffe AC, Darby SC (2013) Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians. BMJ 346:f2360. https://doi.org/10.1136/bmj.f2360
Brenner D, Elliston C, Hall E, Berdon W (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176(2):289–296. https://doi.org/10.2214/ajr.176.2.1760289
Balonov MI, Shrimpton PC (2012) Effective dose and risks from medical X-ray procedures. Ann ICRP 41(3–4):129–141. https://doi.org/10.1016/j.icrp.2012.06.002
ICRP, Khong PL, Ringertz H, Donoghue V, Frush D, Rehani M, Appelgate K, Sanchez R (2013) ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology. Ann ICRP 42(2):1–63. https://doi.org/10.1016/j.icrp.2012.10.001
Simony A, Hansen EJ, Christensen SB, Carreon LY, Andersen MO (2016) Incidence of cancer in adolescent idiopathic scoliosis patients treated 25 years previously. Eur Spine J 25(10):3366–3370. https://doi.org/10.1007/s00586-016-4747-2
Lenke LG, Betz RR, Harms J, Bridwell KH, Clements DH, Lowe TG, Blanke K (2001) Adolescent idiopathic scoliosis: a new classification to determine extent of spinal arthrodesis. J Bone Joint Surg Am 83(8):1169–1181
Mc Arthur N, Conlan DP, Crawford JR (2015) Radiation exposure during scoliosis surgery: a prospective study. Spine J 15(3 Suppl):S33–S36. https://doi.org/10.1016/j.spinee.2014.12.149
Dabaghi Richerand A, Christodoulou E, Li Y, Caird MS, Jong N, Farley FA (2016) Comparison of effective dose of radiation during pedicle screw placement using intraoperative computed tomography navigation versus fluoroscopy in children with spinal deformities. J Pediatr Orthop 36(5):530–533. https://doi.org/10.1097/BPO.0000000000000493
Chan A, Parent E, Narvacan K, San C, Lou E (2017) Intraoperative image guidance compared with free-hand methods in adolescent idiopathic scoliosis posterior spinal surgery: a systematic review on screw-related complications and breach rates. Spine J 17(9):1215–1229. https://doi.org/10.1016/j.spinee.2017.04.001
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
C. Berlin, M. Quante, U. Platz and D. Ivanits state that there is no conflict of interest. B. Thomsen is part of the advisory board for the Silony Medical. M. Koeszegvary has a consultancy agreement with Silony and receives fees for lectures from Nuvasive Inc. H. Halm. has a consultancy agreement and Royalties with Nuvasive Inc. and a consultancy agreement with Silony Medical. The Silony company also finances a study nurse.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Berlin, C., Quante, M., Thomsen, B. et al. Intraoperative radiation exposure to patients in idiopathic scoliosis surgery with freehand insertion technique of pedicle screws and comparison to navigation techniques. Eur Spine J 29, 2036–2045 (2020). https://doi.org/10.1007/s00586-020-06465-w
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00586-020-06465-w