Skip to main content

Advertisement

Log in

Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

It is a retrospective analytic study of 1,009 transpedicular screws (689 thoracic and 320 lumbosacral), inserted with free-hand technique in neuromuscular scoliosis using postoperative CT scan. The aim of paper was to determine the accuracy and safety of transpedicular screw placement with free-hand technique in neuromuscular scoliosis and to compare the accuracy at different levels in such population. All studies regarding accuracy and safety of pedicle screw in scoliosis represent idiopathic scoliosis using various techniques such as free-hand, navigation, image intensifier, etc., for screw insertion. Anatomies of vertebrae and pedicle are distorted in scoliosis, hence accurate and safe placement of pedicle screw is prerequisite for surgery. Between 2004 and 2006, 37 consecutive patients, average age 20 years (9–44 years), of neuromuscular scoliosis were operated with posterior pedicle screw fixation using free-hand technique. Accuracy of pedicle screws was studied on postoperative CT scan. Placement up to 2 mm medial side and 4 mm lateral side was considered within-safe zone. Of the 1,009 screws, 273 screws were displaced medially, laterally or on the anterior side showing that 73% screws (68% in thoracic and 82.5% in lumbar spine) were accurately placed within pedicle. Considering the safe zone, 93.3% (942/1009, 92.4% in thoracic and 95.3% in lumbar spine) of the screws were within the safe zone. Comparing accuracy according to severity of curve, accuracy was 75% in group 1 (curve <90°) and 69% in group 2 (curve >90°) with a safety of 94.8 and 91.2%, respectively (P = 0.35). Comparing the accuracy at different thoracic levels, it showed 67, 64 and 72% accuracy in upper, middle and lower thoracic levels with safety of 96.6, 89.2 and 93.1%, respectively, exhibiting no statistical significant difference (P = 0.17). Pedicle screw placement in neuromuscular scoliosis with free-hand technique is accurate and safe as other conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Barr CJ, Schuette AM, Emans JB (1997) Lumbar pedicle screw versus hooks. Spine 22:1369–1379. doi:10.1097/00007632-199706150-00016

    Article  PubMed  CAS  Google Scholar 

  2. Belmont PJ, Klemme WR, Dhawan A, Polly DW (2001) In vivo accuracy of thoracic pedicle screws. Spine 26(21):2340–2346. doi:10.1097/00007632-200111010-00010

    Article  PubMed  Google Scholar 

  3. Berlet GC, Boubez G, Gurr KR et al (1999) The USS pedicle hook system: a morphometric analysis of its safety in the thoracic spine. J Spinal Disord 12:234–239

    PubMed  CAS  Google Scholar 

  4. Bogler C, Kelleher MO, McEvoy L et al (2007) Electrical conductivity measurement: a new technique to detect iatrogenic initial pedicle perforation. Eur Spine J 16:1919–1924. doi:10.1007/s00586-007-0409-8

    Article  Google Scholar 

  5. Boucher HH (1959) A mehtod of spinal fusion. J Bone Joint Surg Br 41:248–259

    PubMed  Google Scholar 

  6. Broom MJ, Banta JV, Renshaw TS (1989) Spinal fusion augmented by luque-rod segmental instrumentation for neuromuscular scoliosis. J Bone Joint Surg Am 71:32–44

    PubMed  CAS  Google Scholar 

  7. Brown CA, Lenke LG, Bridwell KH, Geideman WM, Hasan SA, Blanke Kathy RN (1998) Complications of pediatric thoracolumbar and lumbar pedicle screws. Spine 23(14):1566–1571. doi:10.1097/00007632-199807150-00012

    Article  PubMed  CAS  Google Scholar 

  8. Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320–1324. doi:10.1097/00007632-199606010-00008

    Article  PubMed  CAS  Google Scholar 

  9. Cinotti G, Gumina S, Ripani M et al (1999) Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine 24:654–658. doi:10.1097/00007632-199904010-00008

    Article  Google Scholar 

  10. Chung KJ, Suh SW, Desai S, Song HR (2007) Ideal entry point for the thoracic pedicle screw during the free hand technique. Int Orhtop Apr 17 (epub ahead of print)

  11. Danesh-Clough T, Taylor P, Hodgson B, Walton M (2001) The use of evoked EMG in detecting misplaced thoracolumbar pedicle screws. Spine 26(12):1313–1316. doi:10.1097/00007632-200106150-00008

    Article  PubMed  CAS  Google Scholar 

  12. Dvorak M, MacDonald S, Gurr KR, Bailey SI, Haddad RG (1993) An anatomic, radiographic and boimechanical assessment of extrapedicular screw fixaiton in thoracic spine. Spine 18:1689–1694. doi:10.1097/00007632-199309000-00018

    Article  PubMed  CAS  Google Scholar 

  13. Ebraheim NA, Jabaly G, Xu R, Yeasting RA (1997) Anatomic relations of the thoracic pedicle to adjacent neural structures. Spine 22:1553–1557. doi:10.1097/00007632-199707150-00002

    Article  PubMed  CAS  Google Scholar 

  14. Ebraheim NA, Xu R, ahmad M, Yeasting RA (1997) Projection of the thoracic pedicle and its morphometric analysis. Spine 22:233–238. doi:10.1097/00007632-199702010-00001

    Article  PubMed  CAS  Google Scholar 

  15. Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18:2231–2239

    Article  PubMed  CAS  Google Scholar 

  16. Faraj AA, Webb JK (1997) Early complications of spinal pedicle screw. Eur Spine J 6:324–326. doi:10.1007/BF01142678

    Article  PubMed  CAS  Google Scholar 

  17. Ferrick MR, Kowalki JM, Simmons ED (1997) Reliability of roentgenogram evaluation of pedicle screw position. Spine 22(11):1249–1252. doi:10.1097/00007632-199706010-00016

    Article  PubMed  CAS  Google Scholar 

  18. Fisher CG, Sahajpal V, Keynan O, Boyd M, Graeb D, Baily C et al (2006) Accuracy and safety of pedicle screw fixation in thoracic spine trauma. J Neurosurg Spine 5:520–526. doi:10.3171/spi.2006.5.6.520

    Article  PubMed  Google Scholar 

  19. Gertzbein SD, Robbins SE (1990) Accuracy of pedicle screw placemment in vivo. Spine 15:11–15. doi:10.1097/00007632-199001000-00004

    Article  PubMed  CAS  Google Scholar 

  20. Girardi FP, Cammisa FP, Sandhu HS, Alvarez L (1999) The placement of lumbar pedicle screws using computerised steriotactic guidance. J Bone Joint Surg Br 81-B(5):825–829. doi:10.1302/0301-620X.81B5.9244

    Article  Google Scholar 

  21. Hamill C, Lenke L, Bridwell K, Chapman M, Blanke K, Baldus C (1996) The use of pedicle screw fixation to improve correction in the lumbar spine patients with idiopathic scoliosis: Is it warranted? Spine 21:1241–1249. doi:10.1097/00007632-199605150-00020

    Article  PubMed  CAS  Google Scholar 

  22. Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: Is it safe? Spine 29(3):333–342. doi:10.1097/01.BRS.0000109983.12113.9B

    Article  PubMed  Google Scholar 

  23. Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27–32. doi:10.1097/00007632-198801000-00007

    Article  PubMed  CAS  Google Scholar 

  24. Krag MH, Beynnon BD, Pope MH, Frymoyer JW, Haugh LD, Weaver DL (1986) An internal fixator for posterior application to short segments of the thoracic, lumbar or lumbosacral spine. Design and testing. Clin Orthop Relat Res 203:75–98

    PubMed  Google Scholar 

  25. Kuklo TR, Lenke LG, O’Brien MF, Lehman RA Jr, Schroeder TM (2005) Accuracy and efficacy of thoracic pedicle screws in curves more than 90 degrees. Spine 30:222–226. doi:10.1097/01.brs.0000150482.26918.d8

    Article  PubMed  Google Scholar 

  26. Kuntz C 4th, Maher PC, Levine NB, Kurokawa R (2004) Prospective evaluation of thoracic pedicle screw placement using fluoroscopic imaging. J Spinal Disord Tech 17:206–208

    Article  PubMed  Google Scholar 

  27. Liljenqvist UR, Halm HF, Link TM (1997) Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 22(19):2239–2245. doi:10.1097/00007632-199710010-00008

    Article  PubMed  CAS  Google Scholar 

  28. Liljenquist UR, Link TM, Halm HF (2000) Morphometric analysis of thoracic and lumbar vertebrae in idiopathic scoliosis. Spine 25(10):1247–1253. doi:10.1097/00007632-200005150-00008

    Article  Google Scholar 

  29. Louis-Philippe A, Karsten L, Michael P, Hartmut Z, Hubert L (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar and sacral spine. Spine 25(5):606–614. doi:10.1097/00007632-200003010-00012

    Article  Google Scholar 

  30. Marty Z, Michael B, Christian K, Joachim L, Christian K, Leonard B (2004) Accuracy of pedicle screw placement in thoracic spine fractures—part II: a retrospective analysis of 278 pedicle screws using computed tomographic scans. Eur J Trauma 30:241–247

    Google Scholar 

  31. Masferrer R, Gomez CH, Karahalios DG, Sonntag VK (1998) Efficacy of pedicle screw fixation in the treatment of spinal instability and failed back surgery: a 5 years review. J Neurosurg 89:371–377

    Article  PubMed  CAS  Google Scholar 

  32. Rampersaud YR, Foley KT, Shen AC et al (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle insertion. Spine 25:2637–2645. doi:10.1097/00007632-200010150-00016

    Article  PubMed  CAS  Google Scholar 

  33. Rampersaud YR, Simon DA, Folry KT (2001) Accuracy requirements for image-guided spinal pedicle screw placement. Spine 26(4):352–359. doi:10.1097/00007632-200102150-00010

    Article  PubMed  CAS  Google Scholar 

  34. Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159

    PubMed  CAS  Google Scholar 

  35. Roy-Camille R, Saillant G, Mazel C (1988) Internal fixation of the lumbar spine with pedicle screw plating. Clin Ortop 203:7–17

    Google Scholar 

  36. Sapkas GS, Papadakis SA, Stathakopoulos DP et al (1999) Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography. A prospective study of 35 patients. Spine 24:1926–1929. doi:10.1097/00007632-199909150-00011

    Article  PubMed  CAS  Google Scholar 

  37. Schhwarzenbach O, Berlemann U, Jost B, Visarius H, Arm E, Langlotz F et al (1997) Accuracy of computer-assisted pedicle screw placement: An in vivo computed tomography analysis. Spine 22(4):452–458. doi:10.1097/00007632-199702150-00020

    Article  Google Scholar 

  38. Steib JP, Dumas R, Mitton D, Skalli W (2004) Surgical correction of scoliosis by in situ contouring: a derotation analysis. Spine 29(2):193–199. doi:10.1097/01.BRS.0000107233.99835.A4

    Article  PubMed  Google Scholar 

  39. Suk SI, Lee CK, Min HJ, Cho KH, Oh JH (1994) Comparision of Cotrel–Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis. Int Orthop 18:341–346. doi:10.1007/BF00187077

    Article  PubMed  CAS  Google Scholar 

  40. Suk SI, Lee CK, Kim W, Chung Y, Park Y (1995) Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine 20:1399–1405. doi:10.1097/00007632-199506000-00012

    Article  PubMed  CAS  Google Scholar 

  41. Suk SI, Kim WJ, Lee SM, Chung ER (2001) Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine 26(18):2049–2057. doi:10.1097/00007632-200109150-00022

    Article  PubMed  CAS  Google Scholar 

  42. Vaccaro AR, Rizzolo SJ, Balderston RA et al (1995) Placement of pedicle screws in the thoracic spine. Part II: an anatomic and radiographic assessment. J Bone Joint Surg Am 77:1200–1206

    PubMed  CAS  Google Scholar 

  43. Weinstein J, Rydevik B, Rauschning W (1992) Anatomic technical considerations of pedicle screw fixation. Clin Orthop Relat Res 284:34–46

    PubMed  Google Scholar 

  44. World Health Organization (2001) International classification of impairment, activity and participation. World Health Organization, Geneva, Switzerland, ICIDH-2

  45. Zeiller SC, Lee J, Lim M, Vaccaro AR (2005) Posterior thoracic segmental pedicle screw instrumentation: evolving methods of safe and effective placement. Neurol India 53(4):458–465

    Article  PubMed  CAS  Google Scholar 

  46. Zindrick MR, Wiltse LL, Widell EH et al (1986) A biomechanical study of intrapedicular screw fixation in the lumbosacral spine. Clin Ortop 203:99–111

    Google Scholar 

Download references

Conflict of interest statement

Each author certifies that he has no commercial associations (e.g., consultancies, stock ownership, equity interests, patent/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Seung Woo Suh.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Modi, H.N., Suh, S.W., Fernandez, H. et al. Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique. Eur Spine J 17, 1686–1696 (2008). https://doi.org/10.1007/s00586-008-0795-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-008-0795-6

Keywords

Navigation