Epidermal antenna in palmar arch region for anaemia detection to avoid peripheral perfusion artifact in optical sensor during hemoglobin measurement

  • Technical Paper
  • Published:
Microsystem Technologies Aims and scope Submit manuscript

Abstract

The anaemia disease diagnosed with various test such as complete blood count (CBC), ferritin measure, reticulocyte count, peripheral smear and blood gas analyser. The ferritin measure the storage and usage of iron in human body, reticulocyte count assess young red blood cell, and Peripheral smear analyse the cell colour, size, and shape of red blood cell through microscopic image. The blood gas analyser measures methemoglobin (MetHb) and carboxyhaemoglobin. Different test measure haemoglobin, since iron level show normal in blood for the patient with low total body iron. The iron deficiency never show symptom or sign in the human body. In this paper, we propose a new non-invasive method for anaemia measure through epidermal antenna over ulnar region of palm and acquire radiating signal from Haemoglobin protein. The acquired signal from epidermal antenna analysed with Transverse Dyadic Wavelet Transform for haemoglobin protein level in red blood cell. The epidermal antenna signal from ulnar region haemoglobin measurement avoids the peripheral perfusion artifact of optical or image sensor which arise during measurement. The experimental analysis show signal of epidermal antenna measure the haemoglobin more accurately, through regression modelling than existing optical and image based point of care device. Experimental result of haemoglobin measurement from ulnar region has validated with blood gas analyser.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  • Al-Khabori M, Al-Riyami AZ, Al-Farsi K et al (2014) Validation of a non-invasive pulse CO-oximetry based haemoglobin estimation in normalblood donors. TransfusApher Sci 50(1):95–98

    Google Scholar 

  • Amendola S, Marrocco G (2017) Optimal performance of epidermal antennas for UHF radio frequency identification and sensing. IEEE Trans Antennas Propag 65(2):473–481

    Article  Google Scholar 

  • Baart AM, de Kort WL, van den Hurk K, Pasker-de Jong PC (2016) Haemoglobin assessment: precision and practicability evaluated in the Netherlands– the HAPPEN study. Transfusion 56(8):1984–1993

    Article  Google Scholar 

  • Cable RG, Steele WR, Melmed RS et al (2011) The difference between fingerstick and venous hemoglobin and hematocrit varies by sex and iron stores. Transfusion 52(5):1031–1040

    Article  Google Scholar 

  • Daae LN, Halvorsen S, Mathisen PM, Mironska K (1988) A comparison between haematological parameters in ‘capillary’ and venous blood from healthy adults. Scand J Clin Lab Invest 48:723–726

    Google Scholar 

  • Hayden SJ, Albert TJ, Watkins TR, Swenson ER (2012) Anemia in critical illness: insights into etiology, consequences, and management. Am J RespirCrit Care Med 185(10):1049–1057

    Article  Google Scholar 

  • Huang Xian et al (2014) Materials and designs for wireless epidermal sensors of hydration and strain. Adv Func Mater 24(25):3846–3854

    Article  Google Scholar 

  • Jacob G, Raj SR, Keitch T et al (2005) Postural pseudoanemia: posture dependent change in hematocrit. Mayo Clin Proc 80(5):611–614

    Article  Google Scholar 

  • Jeong J-W et al (2014) Capacitive epidermal electronics for electrically safe, long-term electrophysiological measurements. Adv Healthc Mater 3(5):642–648

    Article  Google Scholar 

  • Kim D-H, Lu N et al (2011) Epidermal electronics. Science 333(12):838–843

    Article  Google Scholar 

  • Paddle JJ (2002) Evaluation of the haemoglobin colour scale and comparison with the hemocue haemoglobin assay. Bull World Health Organ 80:813–816 [PubMed: 12471402]

    Google Scholar 

  • Quinto L, Aponte JJ, Menendez C, Sacarlal J, Aide P, Espasa M et al (2006) Relationship between haemoglobin and haematocrit in the definition of anaemia. Trop Med Int Health 11:1295–1302 [PubMed: 16903892]

    Article  Google Scholar 

  • Schalk E, Heim MU, Koenigsmann M, Jentsch-Ullrich K (2007) Use of capillary blood count parameters in adults. Vox Sang 93(4):348–353

    Google Scholar 

  • Shander A, Fink A, Javidroozi M, Erhard J, Farmer SL, Corwin H et al (2011) Appropriateness of allogeneic red blood cell, transfusion: the international consensus conference on transfusion, outcomes. Transfus Med Rev 25(232–246):e253

    Google Scholar 

  • Stott GJ, Lewis SM (1995) A simple and reliable method for estimating haemoglobin. Bull World Health Organ 73:369–373 [PubMed: 7614669]

    Google Scholar 

  • Sümnig A, Hron G, Westphal A et al (2015) The impact of noninvasive, capillary, and venous haemoglobin screening on donor deferrals andthe haemoglobin content of red blood cells concentrates: a prospective study. Transfusion 55(12):2847–2854

    Article  Google Scholar 

  • Wood EM, Kim DM, Miller JP (2001) Accuracy of predonation Hct sampling affects donor safety, eligibility, and deferral rates. Transfusion 41:353–359

    Article  Google Scholar 

  • Yang ZW, Yang SH, Chen L, Qu J, Zhu J, Tang Z (2001) Comparison of blood counts in venous, fingertip and arterial blood and their measurement variation. Clin Lab Haematol 23:155–159

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. Kannagi.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kannagi, V., Jawahar, A. Epidermal antenna in palmar arch region for anaemia detection to avoid peripheral perfusion artifact in optical sensor during hemoglobin measurement. Microsyst Technol 26, 1427–1435 (2020). https://doi.org/10.1007/s00542-019-04675-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-019-04675-x

Navigation