Skip to main content
Log in

Fabrication and evaluation of a drag-force type dual flow sensor with an embedded temperature sensor

  • Technical Paper
  • Published:
Microsystem Technologies Aims and scope Submit manuscript

Abstract

We designed and fabricated a drag-force type dual flow sensor with an embedded temperature sensor. For the wide range detection, two devices in varying length (300 and 700 μm) were used. The corrugated structure was applied for high sensitivity, and the paddle structure was also adopted to enhance the air drag force. The sensor measured the wide range air flow rate from 0.5 up to 8 m/s with a step width at 0.5 m/s. The 700 μm-long sensor showed about 1.5 times larger sensitivity than the 300 μm-long sensor in the low air flow. The results showed that the 700 μm-long device is suitable for low velocity measurements. However, the 300 μm-long sensor showed better sensitivity in the higher air flow; thus, the 300 μm-long sensor is suitable for high velocity measurements. In addition, the embedded temperature sensor measured the basic temperature, and the measured sensitivity was compensated by temperature which could affect the flow sensor. It also showed a linear shape in resistance change related with temperature.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14

Similar content being viewed by others

References

Download references

Acknowledgements

This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education (NRF-2012R1A1A1039344 and NRF-2017R1D1A1B03030679).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sang Hoon Lee.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Choi, D.K., Lim, Y.U. & Lee, S.H. Fabrication and evaluation of a drag-force type dual flow sensor with an embedded temperature sensor. Microsyst Technol 24, 1975–1985 (2018). https://doi.org/10.1007/s00542-017-3593-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-017-3593-4

Navigation