Numerical and experimental studies of phase difference effects on flow rate of peristaltic micro-pumps with pumping chambers in series configurations

  • Technical Paper
  • Published:
Microsystem Technologies Aims and scope Submit manuscript

Abstract

This paper studies phase difference effects on the flow rate of peristaltic micro-pumps using numerical and experimental approaches. In numerical simulation, commercial software (CFD-ACE+) is used. To focus on the phase relationship of peristaltic micro-pumps, all geometric parameters of the pump are fixed for a baseline design and the diaphragm motion is assumed as a sinusoidal waveform with a fixed frequency of 1 Hz. The phase difference between neighboring chambers is varied from 30°–120° in 10° increments. The pump configurations include the basic 3-chamber configuration and the configurations with up to 8 chambers in series arrangements. The computational results indicate that the maximum flow rate Q max increases with increasing number of chambers (n). However, the maximum phase difference Δϕ max for the maximum pump flow decreases with increasing number of chambers (n) in series pumps. The diaphragm oscillation amplitude also has a significant impact on the pumping flow rate. In the meantime, experiments are performed in an attempt to validate the computational findings. The pump diaphragm is fabricated using PDMS with iron particle contents, and permanent magnets are employed to actuate the diaphragm into movement. The phase relation between diaphragms are controlled by a set of rotary cams specially designed and fabricated for the experiments. Near rectangular waveform is used in the actuation of diaphragm movement. Results show that despite of the difference between computations and experiments, the basic trends of increasing Q max and decreasing Δϕ max with increasing number of chambers (n) are verified for peristaltic micropumps in series configurations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

Similar content being viewed by others

References

  • Akhavan R, Kammz RD, Shapiro AH (1999) An investigation of transition to turbulence in bounded oscillatory stokes flows part 1. Experiments. J Fluid Mech 225:395–422

    Article  Google Scholar 

  • Boden R, Hjort K, Schweitz JA, Simu U (2008) A metallic micropump for high-pressure microfluidics. J Micromech Microeng 18(11):115009-1–115009-7

  • Du M, Ye X, Wu K, Zhou Z (2009) A peristaltic micro pump driven by a rotating motor with magnetically attracted steel balls. Sensors 9(4):2611–2620

    Article  Google Scholar 

  • Graf NJ, Bowser MT (2008) A soft-polymer piezoelectric bimorph cantilever-actuated peristaltic micropump. Lab Chip 8(10):1664–1670

    Article  Google Scholar 

  • Grosjean C, Tai YC (1999) A thermopneumatic peristaltic micropump. In: Proceedings of Transducers’ 99, Sendai, Japan, pp 1776–1779

  • Huang SB, Wu MH, Cui ZF, Cui Z, Lee GB (2008) A membrane-based serpentine-shape pneumatic micropump with pumping performance modulated by fluidic resistance. J Micromech Microeng 18(4):045008-1–045008-12

  • Jang LS, Yu YC (2008) Peristaltic micropump system with piezoelectric actuators. Microsyst Technol 14(2):241–248

    Article  Google Scholar 

  • Jang LS, Li YJ, Lin SJ, Hsu YC, Yao WS, Tsai MC, Hou CC (2007) A stand-alone peristaltic micropump based on piezoelectric actuation. Biomed Microdevices 9(2):185–194

    Article  Google Scholar 

  • Jang LS, Shu K, Yu YC, Li YJ, Chen CH (2009) Effect of actuation sequence on flow rates of peristaltic micropumps with pzt actuators. Biomed Microdevices 11(1):173–181

    Article  Google Scholar 

  • Jiang PC (2009) Fe-PDMS composite membrane for microfluidic chip applications. Master thesis Institute of Nanotechnology and Microsystems Engineering, National Cheng Kung University, Tainan Taiwan, ROC

  • Kim EG, Sim WC, Oh J, Choi B (2002) A continuous peristaltic micropump using magnetic fluid. In: 2nd annual international IEEE-EMB special topic conference on microtechnologies in medicine and biology, Madison, Wisconsin, USA, pp 509–513

  • Koch C, Remcho V, Ingle J (2009) PDMS and tubing-based peristaltic micropumps with direct actuation. Sens Actuators B Chem 135(2):664–670

    Article  Google Scholar 

  • Laser DJ, Santiago JG (2004) A review of micropumps. J Micromech Microeng 14(6):R35–R64

    Article  Google Scholar 

  • Leu TS, Jiang PC (2010) Fe-PDMS fabricated microchannels for peristaltic pump applications. In: Proceedings of the 5th IEEE international conference on nano/micro engineered and molecular systems, Xiamen, China, pp 646–649

  • Li JH, Kan WH, Jang LS, Hsu YC (2007) A portable micropump system based on piezoelectric actuation. In: The 33rd annual conference of the IEEE industrial electronics society (IECON) Taipei Taiwan, pp 2898–2903

  • Lin Q, Yang B, Xie J, Tai YC (2007) Dynamic simulation of a peristaltic micropump considering coupled fluid flow and structural motion. J Micromech Microeng 17(2):220–228

    Article  Google Scholar 

  • Lotz P, Matysek M, Schlaak HF (2009) Peristaltic pump made of dielectric elastomer actuators. In: Proceedings of SPIE, vol 7287, pp 72872D-1–72872D-8

  • Nagel JJ, Mikhail G, Noh H, Koo J (2006) Magnetically actuated micropumps using an Fe-PDMS composite membrane. In: Proceedings of SPIE on smart structures and materials: smart electronics, MEMS, BioMEMS, and nanotechnology, vol 6172, pp 617213-1–617213-9

  • Nguyen NT, Huang X, Chuan TK (2002) MEMS-micropumps: a review. J Fluids Eng 124(2):384–392

    Article  Google Scholar 

  • Nguyen NT, Pham M, Goo NS (2008) Development of a peristaltic micropump for bio-medical applications based on mini LIPCA. J Bionic Eng 5(2):135–141

    Article  Google Scholar 

  • Oh KW, Rong R, Ahn CH (2005) Miniaturization of pinch-type valves and pumps for practical micro total analysis system integration. J Micromech Microeng 15(12):2449–2455

    Article  Google Scholar 

  • Pan T, Kai E, Stay M, Barocas V, Ziaie B (2004) A magnetically driven PDMS peristaltic micropump. In: Proceedings of the 26th annual international conference of the IEEE EMBS, San Francisco, CA, USA, pp 2639–2642

  • Pilarski PM, Adamia S, Backhouse CJ (2005) An adaptable microvalving system for on-chip polymerase chain reactions. J Immunol Methods 305(1):48–58

    Article  Google Scholar 

  • Shen M, Gijs MAM (2009) High performance magnetic active-valve micropump. In: International conference on solid-state sensors and actuators (Transducers 2009). Denver, Colorado, USA, pp 1234–1237

  • Shen M, Dovat L, Gijs MAM (2011) Magnetic active-valve micropump actuated by a rotating magnetic assembly. Sens Actuators B Chem 154(1):52–58

    Article  Google Scholar 

  • Shoji S, Esashi M (1994) Microflow devices and systems. J Micromech Microeng 4(4):157–171

    Article  Google Scholar 

  • Smits JG (1990) Piezoelectric micropump with three valves working peristaltically. Sens Actuators A 21–23:203–206

    Article  Google Scholar 

  • Trenkle F, Haeberle S, Zengerle R (2009) Normally-closed peristaltic micropump with reusable actuator and disposable fluidic chip. Procedia Chem 1(1):1515–1518

    Article  Google Scholar 

  • Wang CH, Lee GB (2006) Pneumatically driven peristaltic micropumps utilizing serpentine-shape channels. J Micromech Microeng 16(2):341–348

    Article  Google Scholar 

  • Wu MH, Huang SB, Lee GB (2008) A high throughput microfluidic liquid pumping system based on pneumatic micropump with serpentine layout. In: The 4th Asia Pacific conference on transducers and micro/nano technologies (APCOT), Tainan, Taiwan, pp 1–4

  • Xie J, Shih J, Lin Q, Yang B, Tai YC (2004) Surface micromachined electrostatically actuated micro peristaltic pump. Lab Chip 4(5):495–501

    Article  Google Scholar 

  • Yang YJ, Liao HH (2009) Development and characterization of thermopneumatic peristaltic micropumps, J Micromech Microeng 19(2):025003-1–025003-13

Download references

Acknowledgments

This research was supported by Ministry of Science and Technology of Taiwan under grant numbers NSC 101-2923-E-006-001-MY3 and NSC 96-2221-E006-179-MY2. The financial supports are gratefully acknowledged.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tzong-Shyng Leu.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Leu, TS., Gong, DC. & Pan, D. Numerical and experimental studies of phase difference effects on flow rate of peristaltic micro-pumps with pumping chambers in series configurations. Microsyst Technol 23, 329–341 (2017). https://doi.org/10.1007/s00542-015-2529-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-015-2529-0

Keywords

Navigation