Skip to main content
Log in

Hot embossing of poly(lactic acid) films for an embedded cochlear implant stiffener

  • Technical Paper
  • Published:
Microsystem Technologies Aims and scope Submit manuscript

Abstract

Externally attached stiffeners/actuators are required for providing structural rigidity to flexible parylene-based cochlear implants for maintaining a perimodiolar shape in the post-implantation phase. Such backing devices being bulky add dead volume to the implant making the fluid-filled scala tympani chamber more congested during insertion resulting in shallow insertion depth. A thin film parylene array with integrated stiffener will provide a smaller implant cross-section potentially allowing a deeper implantation. A novel fabrication method for embedded cochlear implant stiffener structures by hot embossing of poly(lactic acid) (PLA) films is reported. PLA packaging film has been hot embossed on parylene coated silicon substrates using a custom fixture. Embossing results show good pattern transfer fidelity. Rigidity of the embossed stiffeners has been compared with the structural rigidity of poly (ethylene terephthalate) actuators.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

Explore related subjects

Discover the latest articles, news and stories from top researchers in related subjects.

References

  • Arcand B, Butala N, Shyamsunder S, Friedrich CR (2007) A fluid actuator for thin-film electrodes. ASME J Med Dev 1(1):70–78

    Google Scholar 

  • Belligundu S, Shiakolas PS, Pandey A, Aswath PB (2007) A systematic approach toward optimization of the hot embossing of poly-l-lactic acid for biomedical applications. J Biomed Mater Res B Appl Biomater 85B(2):469–477

    Google Scholar 

  • Bogdanski N, Schulz H, Wissen M, Scheer HC, Zajadacz J, Zimmer K (2004) 3D-hot embossing of undercut structures-an approach to micro-zippers. Microelectron Eng 73–74:190–195

    Article  Google Scholar 

  • Heyderman LJ, Schift H, David C, Gobrecht J, Schweizer T (2000) Flow behavior of thin polymer films used for hot embossing lithography. Microelectron Eng 54:229–245

    Article  Google Scholar 

  • Juang YI-JE, Lee LJ, Koelling KW (2002) Hot embossing in microfabrication. Part I: experimental. Polym Eng Sci 42:539–550

    Article  Google Scholar 

  • Kennedy DW (1987) Multichannel intracochlear electrodes: mechanism of insertion trauma. Laryngoscope 97:42–49

    Google Scholar 

  • Middleton JC (2000) Synthetic biodegradable polymers as orthopedic devices. Biomaterials 21:2335–2346

    Article  MathSciNet  Google Scholar 

  • Tewari R (2007) Force characterization and rigidity analysis of a monolithic cochlear prosthesis actuator. MS Thesis, Michigan Technological University

  • Wardrop P, Whinney D, Rebscher SJ, Luxford W, Leake P (2005) A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrode. II: comparison of Spiral Clarion™ and HiFocus II™ electrodes. Hear Res 203:68–79

    Article  Google Scholar 

  • Wise KD, Bhatti PT, Wang J, Friedrich CR (2008) High-density cochlear implants with position sensing and control. Hear Res 242:22–30

    Article  Google Scholar 

Download references

Acknowledgments

The authors are grateful to Angelique Johnson of University of Michigan for providing parylene array layout designs and related dimensions. We also extend our sincere thanks to Chuck Markley of Plastic Suppliers, Inc. for generously donating EarthFirst® PLA packaging sheets. This work was supported by the Engineering Research Center Program of the National Science Foundation under award number EEC-9986866.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Tewari.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tewari, R., Friedrich, C. Hot embossing of poly(lactic acid) films for an embedded cochlear implant stiffener. Microsyst Technol 16, 1601–1607 (2010). https://doi.org/10.1007/s00542-010-1084-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-010-1084-y

Keywords

Navigation