Peristaltic micropump system with piezoelectric actuators

  • Technical Paper
  • Published:
Microsystem Technologies Aims and scope Submit manuscript

Abstract

This work presents a driving system for a peristaltic micropump that is based on piezoelectric actuation. The effects of the actuation sequence on pump performance are also considered. A valveless peristaltic micropump based on piezoelectric actuation is designed and fabricated using microelectromechanical system technology. The pump has three parts––silicon, Pyrex glass and commercially available bulk PZT (lead zirconate titanate) chips. The peristaltic micropump actuated by PZT chips comprises three chambers that are in series. The driving system consists of an ATmega 8535 microprocessor, a high voltage power supply, three differential amplifiers, a phase controller, an A/D converter, a 555 oscillator and an LCD module. It is supplied via a 110 Vrms 60-Hz AC line and is programmable. The system can produce step-function signals with voltages of up to 100 Vpp and frequencies ranging from 10 Hz to 1 kHz, as the inputs for the pump. Fluid pumping with air is successfully demonstrated. Additionally, 3-, 4- and 6-phase actuation sequences for the pump are designed and used to study the effects on pump performance, as revealed by the flow rate and the displacement of a pump diaphragm. The experimental results show that the flow rate and the displacement of the diaphragm actuated by the 4-phase sequence exceed those actuated by the 3- and 6-phase sequences. A flow rate of 17.6 μl min−1 and a displacement of 2.91 μm (peak-to-peak) in 4-phase peristaltic motion are achieved at 100 Hz and 100 Vpp. The results demonstrate that the pump actuated in the 4-phase sequence is the most efficient. Consequently, the actuation sequences can affect the pump performance.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

Similar content being viewed by others

References

  • Ahn CH, Allen MG (1995) Fluid micropumps based on rotary magnetic actuators. In: Proceedings of the IEEE micro electro mechanical systems (MEMS), pp 408–412

  • Anderssona H, van der Wijngaarta W, Nilssonb P, Enokssona P, Stemme G (2001) A valve-less diffuser micropump for microfluidic analytical systems. Sens Actuators B 72:259–265

    Article  Google Scholar 

  • Cao L, Mantell S, Polla D (2001) Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology. Sens Actuators A 94:117–125

    Article  Google Scholar 

  • Carr JJ, Brown JM (2001) Introduction to biomedical equipment technology, 4th edn. Prentice Hall, Upper Saddle River

    Google Scholar 

  • Francais O, Dufour I (1998) Dynamic simulation of an electrostatic micropump with pull-in and hysteresis phenomena. Sens Actuators A 70:56–60

    Article  Google Scholar 

  • Gopalan KG (1996) Introduction to digital microelectronic circuits. IRWIN Chicago

    Google Scholar 

  • Greiherr G (1997) Micromachines making headway in medical applications. Med Dev Diagn Indus 19(8):50–57

    Google Scholar 

  • Husband B, Bu M, Evans AG. R, Melvin T (2004) Investigation for the operation of an integrated peristaltic micropump. J Micromech Microeng 14:S64–S69

    Article  Google Scholar 

  • Jan G.S (1990) Piezoelectric micropump with three valves working peristaltically. Sens Actuators A 21–23:203–206

    Google Scholar 

  • Jang LS, Li YJ, Lin SJ, Hsu YC, Yao WS, Tsai MC, Hou CC (2007) A stand-alone peristaltic micropump based on piezoelectric actuation. Biomed Microdev 9(2):185–194

    Article  Google Scholar 

  • Lee DS, Ko JS, Kim YT (2004) Bidirectional pumping properties of a peristaltic piezoelectric micropump with simple design and chemical resistance. Thin Solid Films 486:285–290

    Article  Google Scholar 

  • Liao CS, Lee G.B, Wu JJ, Chang CC, Hsieh TM, Huang FC, Luo CH (2005) Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases. Biosens Bioelectron 20:1341–1348

    Article  Google Scholar 

  • Nguyen NT, Huang X, Chuan TK (2002) MEMS-Micropumps: a review. Transact ASME 124:384–391

    Google Scholar 

  • Sedra A, Smith KC (1992) Microelectronics circuits, 4th edn. HRW

  • Shu YC (2002) Shape-memory micropumps. Mat Transact 43(5):1037–1044

    Article  Google Scholar 

  • Tay FEH (2002) Microfluidics and BioMEMS applications. Kluwer, Boston

    Google Scholar 

  • Tsai JH, Lin L (2002) Active microfludic mixer and gas bubble filter driven thermal bubble micropump. Sens Actuator A 97–98:665–671

    Article  Google Scholar 

  • Xie J, Shih J, Lin Q, Yang B, Tai YC (2004) Surface micromachined electrostatically actuated micro peristaltic pump. Lab Chip 4:495–501

    Article  Google Scholar 

Download references

Acknowledgments

This work was supported by the National Science Council (NSC 93-2215-E-006-021) of Taiwan. The authors would like to thank the Center for Micro/Nano Science and Technology, National Cheng Kung University, and National Nano Device Laboratories, Tainan, Taiwan, for equipment access and technical support. Additionally, this work made use of Shared Facilities supported by the Program of Top 100 Universities Advancement, Ministry of Education, Taiwan.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ling-Sheng Jang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jang, LS., Yu, YC. Peristaltic micropump system with piezoelectric actuators. Microsyst Technol 14, 241–248 (2008). https://doi.org/10.1007/s00542-007-0428-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-007-0428-8

Keywords

Navigation