Abstract
Continuous arterial blood pressure measurement is an effective perioperative monitoring method in patients with high-risk comorbidities. Recently, ultrasound guidance has been reported to facilitate radial artery catheterization. A new device, Mill Suss™, has also been developed for visualization of the radial artery and superficial veins using near-infrared laser light. In this study, we hypothesized that the Mill Suss-guided method might reduce the time and the number of attempts required for radial artery catheterization under general anesthesia, as compared to the long-axis in-plane ultrasound-guided method. Seventy-two adult patients aged 20–80 years, ASA physical status I or II, were randomly assigned to the Mill Suss-guided group (Group M: n = 36) or ultrasound-guided group (Group U: n = 36). Primary outcomes were the time required for successful radial artery catheterization and the number of cannulation attempts. There were no significant differences in the characteristics of patients between the two groups. The time required for successful radial artery catheterization was significantly shorter in Group M than in Group U. The number of attempts for successful cannulation was not statistically significantly different between the two groups. However, the results might be different among anesthesiologists well experienced in the ultrasound-guided method.
Similar content being viewed by others
References
Gu WJ, Tie HT, Liu JC, Zeng XT. Efficacy of ultrasound-guided radial artery catheterization: a systematic review and meta-analysis of randomized controlled trials. Crit Care. 2014;18:R93.
White L, Halpin A, Turner M, Wallace L. Ultrasound-guided radial artery cannulation in adult and pediatric populations: a systematic review and meta-analysis. Br J Anaesth. 2016;116:610–7.
Berk D, Gurkan Y, Kus A, Ulugol H, Solak M, Toker K. Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches? J Clin Monit Comput. 2013;27:319–24.
Vogel JA, Haukoos JS, Erickson CL, Liao MM, Theoret J, Sanz GE, Kendall J. Is long-axis view superior to short-axis view in ultrasound-guided central venous catheterization? Crit Care Med. 2015;43(4):832–9.
Edanaga M. The transition from Landmark method to method by the visualization about various anesthetic techniques. J Clin Anesth (Japan). 2017;41:1281–7.
Trabelsi H, Gantri M, Sediki E. Visible and near-infrared laser radiation in a biological tissue. A forward model for medical imaging by optical tomography. Lasers Med Sci. 2010;25:41–53.
Lee D, Kim JY, Kim HS, Lee KC, Lee SJ, Kwak HJ. Ultrasound evaluation of the radial artery for arterial catheterization in healthy anesthetized patients. J Clin Monit Comput. 2016;30:215–9.
Abdalla UE, Ellmaadawey A, Kandeel A. Oblique approach for ultrasound-guided radial artery catheterization vs transverse and longitudinal approaches, a randomized trial. J Clin Anesth. 2017;36:98–101.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors have no conflicts of interest associated with this study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
About this article
Cite this article
Osuda, M., Edanaga, M., Matsumoto, T. et al. Comparison of Mill Suss™-guided radial artery catheterization with the long-axis in-plane ultrasound-guided method under general anesthesia: a randomized controlled trial. J Anesth 34, 464–467 (2020). https://doi.org/10.1007/s00540-020-02749-z