Abstract
Purpose
To investigate how subsequent placement of a catheter into the epidural space after unintentional dural puncture for postoperative analgesia for 36–72 h affected the incidence of post-dural puncture headache (PDPH).
Methods
The records of 52 parturients who had had accidental dural puncture in cesarean delivery were reviewed. The parturients were assigned to two groups. Twenty-eight parturients were assigned to the study group, in whom an epidural catheter was inserted and was used for anesthesia and postoperative analgesia. Twenty-four parturients were assigned to the control group, in whom spinal anesthesia (n = 20) or general anesthesia (n = 4) was applied. For postoperative analgesia in patients with incision pain above visual analog scale (VAS) 3, 3 mg morphine in 15 ml saline was administered through the epidural catheter in the study group, while intramuscular meperidine or tramadol was administered in the control group. Once PDPH was observed, conservative treatment was tried first. If the headache persisted despite conservative treatment, an epidural blood patch was applied through the catheter or a reinserted epidural needle.
Results
The study group demonstrated significant reduction of the incidence of PDPH and reduction in the indication for an epidural blood patch compared to the control group (7.1% vs 58% [P = 0.000] and 3.6% vs 37.5% [P = 0.002], respectively).
Conclusion
Subsequent catheter placement into the epidural space after unintentional dural puncture in cesarean delivery and leaving the catheter for postoperative analgesia for 36–72 h may reduce the incidence of PDPH.
Similar content being viewed by others
References
Shibli KU, Russell IF. A survey of anaesthetic techniques used for caesarean section in the UK in 1997. Int J Obstet Anesth. 2000;9:160–167.
Mcdonald R, Lyons G. Unintentional dural puncture. Anaesthesia. 1988;43:705.
Stride PC, Cooper GM. Dural taps revisited. Anaesthesia. 1993;48:247–255.
Banks S, Paech M, Gurrin L. An audit of epidural blood patch after accidental dural puncture with a Tuohy needle in obstetric patients. Int J Obstet Anesth. 2001;10:172–176.
Choi PT, Galinski SE, Takeuchi L, Lucas S, Tamayo C, Jadad AR. PDPH is a common complication of neuraxial blockade in parturients: a meta-analysis of obstetrical studies. Can J Anaesth. 2003;50:460–469.
Scavone BM, Wong CA, Sullivan JT, Yaghmour E, Sherwani SS, McCarthy RJ. Efficacy of a prophylactic epidural blood patch in preventing post dural puncture headache in parturients after inadvertent dural puncture. Anesthesiology. 2004;101:1422–1427.
Turnbull DK, Shepherd DB. Post-dural puncture headache: pathogenesis, prevention and treatment. Br J Anaesth. 2003;91:718–729.
Munnur U, Suresh MS. Backache, headache, and neurologic deficit after regional anesthesia. Anesthesiol Clin North America. 2003;21:71–86.
Warwick WI, Neal JM. Beyond spinal headache: prophylaxis and treatment of low-pressure headache syndromes. Reg Anesth Pain Med. 2007;32:455–461.
Thew M, Paech MJ. Management of postdural puncture headache in the obstetric patient. Curr Opin Anaesthesiol. 2008;21:288–292.
Stride PC, Cooper GM. Dural taps revisited: a 20-year survey from Birmingham Maternity Hospital. Anaesthesia. 1993;48:247–255.
Bart AJ, Wheeler AS. Comparison of epidural saline placement and epidural blood placement in the treatment of post-lumbar puncture headache. Anesthesiology. 1978;48:221–223.
Gaucher DT, Perez JA. Subdural hematoma following lumbar puncture. Arch Int Med. 2002;162:1904–1905.
Diaz J. Permanent paraparesis and cauda equina syndrome after epidural blood patch for post-dural puncture headache. Anesthesiology. 2002;96:1515–1517.
Sudlow C, Warlow C. Epidural blood patching for preventing and treating post-dural puncture headache (Cochrane Review). 3rd ed. Chisester: John Wiley & Sons; 2004. Cochrane Database Syst Rev. 2002;(2):CD001791.
Cohen S, Amar D, Pantuck EJ, Singer N, Divon M. Decreased incidence of headache after accidental dural puncture in caesarean delivery patients receiving continuous postoperative intrathecal analgesia. Acta Anaesthesiol Scand. 1994;38:716–718.
Dennehy KC, Rosaeg OP. Intrathecal catheter insertion during labour reduces the risk of post-dural puncture headache. Can J Anaesth. 1998;45:42–45.
Ayad S, Demian Y, Narouze SN, Tetzlaff JE. Subarachnoid catheter placement after wet tap for analgesia in labor: influence on the risk of headache in obstetric patients. Reg Anesth Pain Med. 2003;28:512–515.
Horlocker TT, McGregor DG, Matsushige DK, Chantigian RC, Schroeder DR, Besse JA. Neurologic complications of 603 consecutive continuous spinal anesthetics using macrocatheter and microcatheter techniques. Anesth Analg. 1997;84:1063–1070.
Rosenblatt MA, Bernstein HH, Beilin Y. Are subarachnoid catheters really safe? Reg Anesth Pain Med. 2004;29:298.
Dittmann M, Schafer HG, Ulrich J, Bond-Taylor W. Anatomical reevaluation of lumbar dura mater with regard to postspinal headache. Effect of dural puncture. Anaesthesia. 1988;43:635–637.
Eldor J, Guedj P. Epidural morphine for prophylaxis of post dural puncture headache in parturients. Reg Anesth. 1992;17:112.
Paech M, Banks S, Gurrin L. An audit of accidental dural puncture during epidural insertion of a Tuohy needle in obstetric patients. Int J Obstet Anesth. 2001;10:162–167.
Reynolds F. Dural puncture and headache. Avoid the first but treat the second. BMJ. 1993;306:874–876.
Cook TM. Combined spinal-epidural techniques. Anaesthesia. 2000:55;42–64.
Bernards C, Kopacz D, Michel M. Effect of needle puncture on morphine and lidocaine flux through the spinal meninges of the monkey. Anesthesiology. 1994:80;853–858.
Suzuki N, Koganemaru M, Onizuka S, Takasaki M. Dural puncture with a 26-gauge spinal needle affects spread of epidural anesthesia. Anesth Analg. 1996;82:1040–1042.
Swenson JD, Lee TH, McJames S. The effect of prior dural puncture on cerebrospinal fluid sufentanil concentrations in sheep after the administration of epidural sufentanil. Anesth Analg. 1998:86;794–796.
Thomas JA, Pan PH, Harris LC, Owen MD, D’Angelo R. Dural puncture with a 27-gauge whitacre needle as part of a combined spinal-epidural technique does not improve labor epidural catheter function. Anesthesiology. 2005:103;1046–1051.
Author information
Authors and Affiliations
About this article
Cite this article
Cesur, M., Alici, H.A., Erdem, A.F. et al. Decreased incidence of headache after unintentional dural puncture in patients with cesarean delivery administered with postoperative epidural analgesia. J Anesth 23, 31–35 (2009). https://doi.org/10.1007/s00540-008-0690-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00540-008-0690-7