Aberrant halt of syringe pump motion: an improved system to prevent false setting of the syringe

  • Published:
Journal of Anesthesia Aims and scope Submit manuscript

Abstract

A syringe pump is used to inject precise doses of drugs having a strong action; for example, vasoactive drugs. Unexpected and undetected halt of a syringe pump can lead to potentially life-threatening complications. We experienced a sudden halt in the movement of a syringe pump (Terufusion syringe pump; Terumo, Tokyo, Japan) in two patients while administering norepinephrine in the intensive care unit (ICU). Fortunately, the patients had only transient hypotension, which was immediately detected and promptly treated, without any untoward sequelae. As a result of the occurrence of such cases, we conducted a detailed investigation of the causes of this sudden halt in the syringe pump. We could not reproduce the aberration of the syringe pump and thus could not specify the cause in the first patient. In the second patient, however, a false setting on the syringe was suspected to be the cause of the problem. In order to prove this, we tried to reproduce the situation where a syringe pump, due to a false syringe setting, abruptly terminated while giving a “syringe loss” warning, after a period of precise functioning. Once we had determined how a false setting of the syringe could occur without the syringe pump giving off an alarm from the onset, we collaborated with the Terumo Company to revise their current instruction manual to incorporate this as a warning. We also helped in the development of a new model, including a new safety feature that would prevent a false setting of the syringe from occurring at all. This new model was released in December 2003.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P Ford D Wood (1995) ArticleTitleProblems during infusions. Severe electrical shock occurred during use of Welmed P1000 syringe pump BMJ 310 1271 Occurrence Handle1:STN:280:ByqB1cvntFc%3D Occurrence Handle7767221

    CAS  PubMed  Google Scholar 

  2. J Tokumine K Sugahara K Gushiken M Ohta T Matsuyama S Saikawa (2005) ArticleTitleNon-zero basal oxygen flow a hazard to anesthesia breathing circuit leak test Anesth Analg 100 1056–1058 Occurrence Handle10.1213/01.ANE.0000147666.28051.BB Occurrence Handle15781521

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

About this article

Cite this article

Tokumine, J., Sugahara, K., Nitta, K. et al. Aberrant halt of syringe pump motion: an improved system to prevent false setting of the syringe. J Anesth 20, 118–121 (2006). https://doi.org/10.1007/s00540-005-0382-5

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00540-005-0382-5

Key words

Navigation