Summary
The new Guideline 19 on the design of mixed-sewage discharge issued by the Austrian Water and Waste Management Association (ÖWAW) in October 2007 defines the Austrian state of the art in the design of mixed-sewage discharge facilities. This new guideline provides that a so-called minimum level of conveyance efficiency (that is the proportion of precipitation that is passed on to the water treatment works) should be proved and observed for the entire catchment area served by a water treatment works, using long-term simulation and calibrated models. By comparison with earlier techniques, the new method of design, based on this comprehensive approach which considers the entire catchment area, offers the possibility of greater flexibility in dealing with mixed-sewage retention. Position, size and distribution of the mixed-sewage structures can be varied as necessary, while alternative methods are also feasible, such as sewer-system management or increasing the maximum inflow to water works. It is thus possible to develop flexible solutions for minimising mixed-sewage discharge flows to suit the respective situation. The OPTIMISCH research project has studied the new methods provided in ÖWAW Guideline 19 (2007) for four catchments of different complexities and performed comprehensive sensitivity analyses for the model parameters and basic data.
Zusammenfassung
Das neue ÖWAV-Regelblatt 19 – "Richtlinien für die Bemessung von Mischwasserentlastungen" definiert seit Oktober 2007 in Österreich den Stand der Technik bezüglich der Bemessung von Mischwasserentlastungen. Nach dem neuen Regelblatt ist ein so genannter Mindestwirkungsgrad der Weiterleitung für das gesamte Einzugsgebiet einer Kläranlage mittels Langzeitsimulation und kalibrierter Modelle nachzuweisen und einzuhalten. Durch die einzugsgebietsweite Betrachtung bietet diese neue Art der Bemessung im Vergleich zu bisherigen Methoden die Möglichkeit, den Rückhalt von Mischwasser flexibler zu erreichen. Lage, Größe und Verteilung der Mischwasserbauwerke können dabei beliebig variiert werden, alternative Methoden wie Kanalnetzbewirtschaftung oder Erhöhung des maximalen Kläranlagenzuflusses sind ebenfalls zulässig. Dadurch ist es möglich, angepasst an die jeweilige Situation, flexible Lösungen zur Minimierung von Mischwasserentlastungsmengen zu entwickeln. Im Rahmen des Forschungsprojektes OPTIMISCH wurde die neue Methodik des ÖWAV Regelblattes 19 (2007) anhand von vier unterschiedlich komplexen Einzugsgebieten untersucht und umfangreiche Sensitivitätsanalysen bezüglich der Modellparameter und der Grundlagendaten durchgeführt.
Similar content being viewed by others
Explore related subjects
Discover the latest articles and news from researchers in related subjects, suggested using machine learning.Literatur
Gruber, G., Winkler, S. and Pressl, A. (2005). "Continuous monitoring in sewer networks an approach for quantification of pollution loads from CSOs into surface water bodies." Water Science and Technology, 52(12), 215–223
Hochedlinger, M. (2005). "Assessment of Combined Sewer Overflow Emissions." Graz: Institut für Siedlungswasserwirtschaft und Landschaftswasserbau
itwh (2008.) "KOSIM 7.2 - Modellbeschreibung." Hannover, Germany: Institut für technisch-wissenschaftliche Hydrologie
Muschalla, D. (2006). "Evolutionäre multikriterielle Optimierung komplexer wasserwirtschaftlicher Systeme." Technische Universität Darmstadt
Muschalla, D., Ostrowski, M.W., Pereira, C. and Schneider, S. (2006). "Dokumentation des Schmutzfrachtmodells SMUSI Version 5.0." Darmstadt: Institut für Wasserbau und Wasserwirtschaft, Technische Universität Darmstadt
Muschalla, D., Schneider, S., Gamerith, V., Gruber, G. and Schroeter, K. (2008). "Sewer modelling based on highly distributed calibration data sets and multi-objective auto-calibration schemes." Water Science and Technology, 57(10), 1547–1554
OEWAV (2007a) "ÖWAV-Leitfaden – Niederschlagsdaten zur Anwendung der ÖWAV-Regelblätter 11 und 19." Wien: Österreichischer Wasser- und Abfallwirtschaftsverband
OEWAV (2007b) "ÖWAV - Regelblatt 19 – Richtlinien für die Bemessung von Mischwasserentlastungen." Wien: Österreichischer Wasser- und Abfallwirtschaftsverband, 47
Rauch, W. und de Toffol, S. (2006). "Der Einfluss der Regencharakteristik auf den Wirkungsgrad von Mischwasserbehandlungsanlagen." Wiener Mitteilungen - Wasser, Abwasser, Gewässer, 196(Kanalmanagement 2006 – Praxisberichte und Projektergebnisse), G1 - G23
Schneider, S. (2007). "Modellierung eines Mischwassernetzes auf der Grundlage von hoch aufgelösten Online-Messwerten und Auto-Kalibrierungsansätzen." TU Darmstadt
De Toffol, S.; Kleidorfer, M. und Rauch, W. (2006): Vergleich hydrodynamischer und hydrologischer Simulationsmodelle bei der Berechnung der Emissionen von Mischwasserbehandlungsanlagen. In: Wiener Mitteilungen, Vol. 196, S. H1–H20
Kleidorfer, M.; Fach, S.; Möderl, M. und Rauch, W. (2007): Umsetzung von Kanalnetzsteuerungen in hydrologischen Modellen am Beispiel von Linz. In: Österreichische Wasser- und Abfallwirtschaft, Vol. 59(9-10), S. 131–137
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Flamisch, N., Gamerith, V., Gruber, G. et al. Forschungsprojekt OPTIMISCH – Optimierte Bemessung von Mischwasserentlastungen. Österr Wasser- und Abfallw 64, 277–284 (2012). https://doi.org/10.1007/s00506-012-0371-5
Issue Date:
DOI: https://doi.org/10.1007/s00506-012-0371-5