Table 2. Number of tested cells per type DOD and charge/discharge settings

From: Ante-mortem analysis, electrical, thermal, and ageing testing of state-of-the-art cylindrical lithium-ion cellsAnte-Mortem-Analyse sowie elektrische, thermische und Alterungstests von State-of-the-Art zylindrischen Lithium-Ionen-Zellen

# DOD in % Charge settings Discharge settings
1 100 1 C CC, VMAX CV@C/20 1 C CC, VMIN CV@C/20
3 80 1 C CC, 4.055 V CV@C/20 1 C CC, 3.210 V CV@C/20
1 60 1 C CC, 3.980 V CV@C/20 1 C CC, 3.421 V CV@C/20
1 80 0.5 C CC, 4.055 V CV@C/20 1 C CC, 3.210 V CV@C/20
1 100 1 C CP, Vmax CV@C/20 OEM1 [10], PP to VMIN
1 80 1 C CP, Vmax CV@C/20 OEM2 [10], PP to 3.210 V