Summary

In public low-voltage grids, the protection of the general public is ensured by the safety measure TN system. In order to ensure sufficient operating current for the protection devices a sufficient low-ohmic closed loop in the zero sequence system must be provided in addition to a current source with adequate short circuit current capability. If the formation of autonomous low-voltage islands is intended, the tripping condition in the TN system must be guaranteed even under varying grid extensions. Normally, in ring main units the medium to low voltage transformer supplies both a low-ohmic zero sequence return path and the required current carrying capability. If such a transformer is not available, the tripping condition can be met by the combination of a grounding transformer in connection with a specially designed short current source.

Zusammenfassung

In öffentlichen Niederspannungsnetzen wird der Personenschutz durch die Schutzmaßnahme Nullung sichergestellt. Für einen ausreichenden Abschaltstrom muss ein niederohmiger und geschlossener Pfad im Nullsystem (Sternpunktbildung, durchgängiger PEN-Leiter) und eine ausreichende Fähigkeit der Einspeiser zur Kurzschlussstrom-Lieferung gegeben sein. Da man bei der gewollten Bildung von autonomen Niederspannungsinseln die Einhaltung der Abschaltbedingung trotz variabler Netzverhältnisse sicherstellen muss und der Ortsnetz-Transformator dafür nicht zur Verfügung steht, kann man durch die Kombination eines an geeigneten Stellen eingebauten Sternpunktbildners und einer entsprechenden für diesen Zweck vorgehaltenen Stromquelle diese Bedingung erfüllen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • E-Control (2004): Technische und Organisatorische Regeln für Betreiber und Benutzer von Netzen. Teil D: Besondere technische Regeln

  • Elektrotechnikgesetz (1992): BGBl. Nr. 106/1993, 1.4.1993

  • Fickert, L. (2003): Der Erdschluss. Multimediale Bildungs-CD-ROM. TU Graz

  • Hubensteiner, H., et al. (1993): Schutztechnik in elektrischen Netzen 1. Grundlagen und Ausführungsbeispiele. Berlin: VDE-Verlag

    Google Scholar 

  • IEC/TS 61201 Ed. 2.0 b (bilingual) (2007–08): Use of conventional touch voltage limits – Application guide

  • IEC/TS 60479-1 Ed. 4.0 b (bilingual) (2005–07): Effects of current on human beings and livestock – Part 1: General aspects

  • IEC/TS 60479-2 Ed. 3.0 b (bilingual) (2007-05): Effects of current on human beings and livestock – Part 2: Special aspects

  • IEC/TS 60479-3 Ed. 1.0 b (bilingual) (1998–09): Effects of current on human beings and livestock – Part 3: Effects of currents passing through the body of livestock

  • IEC/TR 60479-4 Ed. 1.0 b (bilingual) (2004–07): Effects of current on human beings and livestock – Part 4: Effects of lightning strokes on human beings and livestock

  • IEC/TR 60479-5 Ed. 1.0 b (bilingual) (2007–11): Effects of current on human beings and livestock – Part 5: Touch voltage threshold values for physiological effects

  • ITU-T, K.68 (04/2008) SERIES K: Protection against interference. Management of electromagnetic interference on telecommunication systems due to power systems and operators' responsibilities

  • MacDonald, R. (2007): Public Interest Energy Research Program. California Energy Commission, http://www.energy.ca.gov/2007_energypolicy/documents/2007-0510_workshop/presentations/PM%203%20Rachel%20MacDonald%20of%20PIER%20Distribution%20Program.pdf (2009-01-16)

  • Nullungsverordnung (1998): Bundesgesetzblatt für die Republik Österreich. Jahrgang 1998. Ausgegeben am 16. September 1998. Teil II

  • ÖVE/ÖNORM E 8001-1/A4: Errichtung von elektrischen Anlagen mit Nennspannungen bis AC 1000 V und DC 1500 V – Teil 1: Begriffe und Schutz gegen elektrischen Schlag (Schutzmaßnahmen)

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fickert, L., Schmautzer, E., Aigner, M. et al. Personensicherheit in autonomen Niederspannungsinseln. Elektrotech. Inftech. 126, 88–93 (2009). https://doi.org/10.1007/s00502-009-0627-3

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00502-009-0627-3

Keywords

Schlüsselwörter

Navigation