Skip to main content

Advertisement

Log in

Automatic generation control of a multi-area power system with renewable energy source under deregulated environment: adaptive fuzzy logic-based differential evolution (DE) algorithm

  • Methodologies and Application
  • Published:
Soft Computing Aims and scope Submit manuscript

Abstract

In this paper, an adaptive fuzzy logic-based differential evolution (DE) algorithm is proposed to optimize the gain of proportional–integral–derivative (PID) controllers. Using the proposed controller, the speed regulation parameters are tuned. Here, fuzzy logic is used to generate the controlled range of population set to DE algorithm. So that most favourable offspring population is created and the drawback of conventional DE algorithm is reduced. Using the proposed controller, the approximation errors and the external disturbance effects are minimized. The proposed method is implemented in MATLAB/Simulink working platform and the effectiveness is verified by multi-source two-area power generation system with renewable energy source. Three test cases are used to evaluate the simulation behaviour of proposed method. Simulation results of the tested power systems prove the effectiveness of the proposed load frequency control and proved its superiority over traditional PID controller, DE-tuned PID controller and fuzzy logic—DE algorithm-based PID controller. Comparison results show that proposed method has less overshoot, undershoot and fast settling time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  • Alajmi BN, Ahmed KH, Finney SJ, Williams BW (2011) Fuzzy logic control approach of a modified hill-climbing method for maximum power point in microgrid standalone photovoltaic system. IEEE Trans Power Electron 26(4):1022–1030

    Article  Google Scholar 

  • Alam MN, Das B, Pant V (2015) A comparative study of metaheuristic optimization approaches for directional overcurrent relays coordination. Electr Power Syst Res 128:39–52

    Article  Google Scholar 

  • Apostolopoulou D, Dominguez-Garcia AD, Sauer PW (2015) An assessment of the impact of uncertainty on automatic generation control systems. IEEE Trans Power Syst 31(4):2657–2665

    Article  Google Scholar 

  • Arqub OA, Abo-Hammour Z (2014) Numerical solution of systems of second-order boundary value problems using continuous genetic algorithm. Inf Sci 279:396–415

    Article  MathSciNet  Google Scholar 

  • Arqub OA, Mohammed AS, Momani S, Hayat T (2016) Numerical solutions of fuzzy differential equations using reproducing kernel Hilbert space method. Soft Comput 20(8):3283–3302

    Article  Google Scholar 

  • Arqub OA, Al-Smadi M, Momani S, Hayat T (2017) Application of reproducing kernel algorithm for solving second-order, two-point fuzzy boundary value problems. Soft Comput 21(23):7191–7206

    Article  Google Scholar 

  • Arya Y, Kumar N (2016) AGC of a multi-area multi-source hydrothermal power system interconnected via AC/DC parallel links under deregulated environment. Electr Power Energy Syst 75:127–138

    Article  Google Scholar 

  • Bhateshvar YK, Mathur HD, Siguerdidjane H, Bhanot S (2015) Frequency stabilization for multi-area thermal–hydro power system using genetic algorithm-optimized fuzzy logic controller in deregulated environment. Electr Power Compon Syst 43(2):146–156

    Article  Google Scholar 

  • Cheng Y, Tabrizi M, Sahni M, Povedano A, Nichols D (2014) Dynamic available AGC based approach for enhancing utility scale energy storage performance. Electr Power Energy Syst 5(2):1070–1078

    Google Scholar 

  • Dash P, Saikia LC, Sinha N (2015) Comparison of performances of several FACTS devices using Cuckoo search algorithm optimized 2DOF controllers in multi-area AGC. Int J Electr Power Energy Syst 65:316–324

    Article  Google Scholar 

  • Dhillon SS, Lather JS, Marwaha S (2016) Multi objective load frequency control using hybrid bacterial foraging and particle swarm optimized PI controller. Electr Power Energy Syst 79:196–209

    Article  Google Scholar 

  • Elsisi M, Soliman M, Aboelela MAS, Mansour W (2016) Bat inspired algorithm based optimal design of model predictive load frequency control. Electr Power Energy Syst 83:426–433

    Article  Google Scholar 

  • Fahmi A, Abdullah S, Amin F, Siddque N, Ali A (2017) Aggregation operators on triangular cubic fuzzy numbers and its application to multi-criteria decision making problems. J Intell Fuzzy Syst 33:3323–3337

    Article  Google Scholar 

  • Fahmi A, Abdullah S, Amin F, Ali A (2018a) Weighted average rating (war) method for solving group decision making problem using triangular cubic fuzzy hybrid aggregation (Tcfha). Punjab Univ J Math 50(1):23–34

    MathSciNet  Google Scholar 

  • Fahmi A, Abdullah S, Amin F, Ali A, Khan WA (2018b) Some geometric operators with triangular cubic linguistic hesitant fuzzy number and their application in group decision-making. J Intell Fuzzy Syst. https://doi.org/10.3233/jifs-18125

    Article  Google Scholar 

  • Fahmi A, Abdullah S, Amin F, Khan MSA (2018c) Trapezoidal cubic fuzzy number einstein hybrid weighted averaging operators and its application to decision making. Soft Comput. https://doi.org/10.1007/s00500-018-3242-6

    Article  MATH  Google Scholar 

  • Fahmi A, Amin F, Smarandache F, Khan M, Hassan N (2018d) Triangular cubic hesitant fuzzy einstein hybrid weighted averaging operator and its application todecision making. Symmetry 10(11):658

    Article  Google Scholar 

  • Hota PK, Mohanty B (2016) Automatic generation control of multi source power generation under deregulated environment. Electr Power Energy Syst 75:205–214

    Article  Google Scholar 

  • Mohanty B, Hota PK (2015) Comparative performance analysis of fruit fly optimisation algorithm for multi-area multisource automatic generation control under deregulated environment. IET Gener Transm Distrib 9(14):1845–1855

    Article  Google Scholar 

  • Naidu K, Mokhlis H, Bakar AHA, Terzija V, Illias HA (2014) Application of firefly algorithm with online wavelet filter in automatic generation control of an interconnected reheat thermal power system. Electr Power Energy Syst 63:401–413

    Article  Google Scholar 

  • Omar Abu Arqub (2017) Adaptation of reproducing kernel algorithm for solving fuzzy Fredholm-Volterra integrodifferential equations. Neural Comput Appl 28(7):1591–1610

    Article  Google Scholar 

  • Sahu RK, Panda S, Sekhar GC (2015) A novel hybrid PSO-PS optimized fuzzy PI controller for AGC in multi area interconnected power systems. Electr Power Energy Syst 64:880–893

    Article  Google Scholar 

  • Sekhar GC, Sahu RK, Baliarsingh AK, Panda S (2016) Load frequency control of power system under deregulated environment using optimal firefly algorithm. Electr Power Energy Syst 74:195–211

    Article  Google Scholar 

  • Sharma G, Nasiruddin I, Niazi KR, Bansal RC (2016) Optimal AGC of a multi-area power system with parallel AC/DC tie lines using output vector feedback control strategy. Electr Power Energy Syst 81:22–31

    Article  Google Scholar 

  • Shiva CK, Mukherjee V (2015) Automatic generation control of multi-unit multi-area deregulated power system using a novel quasi-oppositional harmony search algorithm. IET Gener, Transm Distrib 9(15):2398–2408

    Article  Google Scholar 

  • Singh S, Parmar KP, Majhi S, Kothari DP (2012) Load frequency control of a realistic power system with multi-source power generation. Electr Power Energy Syst 42:426–433

    Article  Google Scholar 

  • Sundararaj V (2016) An efficient threshold prediction scheme for wavelet based ECG signal noise reduction using variable step size firefly algorithm. Int J Intell Eng Syst 9(3):117–126

    Google Scholar 

  • Sundararaj V (2018) Optimal task assignment in mobile cloud computing by queue based Ant-Bee algorithm. Wirel Pers Commun. https://doi.org/10.1007/s11277-018-6014-9

    Article  Google Scholar 

  • Sundararaj V, Muthukumar S, Kumar RS (2018) An optimal cluster formation based energy efficient dynamic scheduling hybrid MAC protocol for heavy traffic load in wireless sensor networks. Comput Secur 77:277−288

    Article  Google Scholar 

  • Xie P, Li Y, Zhu L, Shi D, Duan X (2016) Supplementary automatic generation control using controllable energy storage in electric vehicle battery swapping stations. IET Gener Transm Distrib 10(4):1107–1116

    Article  Google Scholar 

  • Yousef H (2015) Adaptive fuzzy logic load frequency control of multi-area power system. Electr Power Energy Syst 68:384–395

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. Ajithapriyadarsini.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Additional information

Communicated by V. Loia.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ajithapriyadarsini, S., Mary, P.M. & Iruthayarajan, M.W. Automatic generation control of a multi-area power system with renewable energy source under deregulated environment: adaptive fuzzy logic-based differential evolution (DE) algorithm. Soft Comput 23, 12087–12101 (2019). https://doi.org/10.1007/s00500-019-03765-2

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00500-019-03765-2

Keywords

Navigation