Abstract
The prescription of peritoneal dialysis should be individualized based on parameters of tolerance and adequacy. Determination of the intraperitoneal fill volume is essential for optimal patient care. Fill volume enhancement is a factor of exchange surface area recruitment: the wetted, contact peritoneal dialysis membrane. Nevertheless, fill volume enhancement can also lead to patient discomfort, with the potential risk of too high an intraperitoneal pressure (hernia, gastro-esophageal reflux). The perception of the individual patient is also a subjective parameter of fill volume tolerance assessment. In contrast, measurement of the hydrostatic intraperitoneal pressure (IPP, cmH2O) allows an objective approach to fill volume tolerance. From our clinical experience of more than 10 years of IPP measurements in child care, we can give a recommendation for normal values in children: less than 18 cm of water, usually between 5 and 15 cm, correlated to the intraperitoneal fill volume (naturally), but individually taking into account age, gender, "accustomization" and overall body mass index.
Similar content being viewed by others
References
Fischbach M, Terzic J, Menouer S, Haraldsson B (2000) Optimal volume prescription for children on peritoneal dialysis. Perit Dial Int 20:603–606
Durand PY (2000) Optimization of fill volumes in automated peritoneal dialysis. Perit Dial Int 20:601–602
Fischbach M, Stefanidis CJ, Watson A for the European Pediatric Dialysis Working Group (2002) Guidelines by an ad hoc European committee on adequacy of the pediatric peritoneal dialysis prescription. Nephrol Dial Transplant 17:380–385
Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1996) Measurement of hydrostatic intraperitoneal pressure: a necessary routine test. Perit Dial Int 16:S84–S87
Fischbach M, Terzic J, Becmeur F, Lahlou A, Desprez P, Battouche D, Geisert J (1996) Relationship between intraperitoneal hydrostatic pressure and dialysate volume in children on PD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 16:330–340
Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1992) Routine measurement of hydrostatic intraperitoneal pressure. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 8:108–112
Fischbach M, Terzic J, Dangelser C, Schneider P, Roger ML, Geisert J (1997) Improved dialysis dose by optimizing intraperitoneal volume prescription thanks to intraperitoneal pressure measurements in children. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 13:271–273
Ventura MJ, Amato D, Correa-Rotter R, Paniagna R (2000) Relationship between fill volume, intraperitoneal pressure, body size and subjective discomfort perception in CAPD patients. Perit Dial Int 20:188–193
Scanziani R, Dozio B, Pasi A, Sangalli L, Bonforte G, Rivera R, Surian M (2001) Optimization of dialysate flow on automated peritoneal dialysis (APD). Perit Dial Int 21 (Suppl 1) S31 (abstract)
Fischbach M, Terzic J, Menouer S, Provot E, Laugel V (2001) Relationship between fill volume (IPV), intraperitoneal pressure (IPP) and body mass index in children on chronic peritoneal dialysis (PD). Perit Dial Int 21 (Suppl 1) S88 (abstract); Perit Dial Int 2003 (in press)
Barak N, Ehrenpreis ED, Harrison JR, Sitrin MD (2002) Gastro-oesophageal reflux disease in obesity: pathophysiological and therapeutic considerations. Obes Rev 3:9–15
Fischbach M, Terzic J, Schneider P, Roger ML (1998) Effect of posture on intraperitoneal pressure and peritoneal equilibration test in children. Pediatr Nephrol 12:311–314
Fischbach M, Desprez P, Donnars F, Geisert J (1994) Hydrostatic intraperitoneal pressure in children on peritoneal dialysis: practical implications. An 18-month clinical experience. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 10:294–296
Fischbach M, Terzic J, Chauve S, Laugel V, Muller A, Haraldsson B (2003) In children, the peritoneal area available for exchange is influenced by the composition of the peritoneal dialysis fluid. J Am Soc Nephrol (in press)
Fischbach M, Lahlou A, Becmeur F, Desprez P, Geisert J (1995) Hydrostatic intraperitoneal pressure in infants on peritoneal dialysis: interest after surgical peritoneal catheter implantation. Pediatr Nephrol 9:C44 (abstract)
Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1993) Intraperitoneal hydrostatic pressure and ultrafiltration volume in CAPD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 9:46–48
Aranda RA, Romao Junior JE, Kakehashi E, Domingos W, Sabbaga E, Marcondes M, Abensur H (2000) Intraperitoneal pressure and hernias in children on peritoneal dialysis. Pediatr Nephrol 14:22–24
Fischbach M, Terzic J, Gaugler C, Bergere C, Munch K, Hamel G, Provot E, Donnars F (1998) Impact of an increased intraperitoneal fill volume both on tolerance and on dialysis effectiveness in children In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 14:258–264
Keshaviah P, Emerson PF, Vonesh EF, Brandes JC (1994) Relationship between body size, fill volume and mass transfer coefficient in peritoneal dialysis. J Am Soc Nephrol 4:1870–1876
Brandes JC, Packard WJ, Walters SK, Fritsche C (1995) Optimization of dialysate flow and mass transfer during automated peritoneal dialysis. Am J Kidney Dis 25:603–610
Fischbach M, Haraldsson B (2001) Dynamic changes of total pore area available for peritoneal exchange in children. J Am Soc Nephrol 12:1524–1529
Chagnac A, Herskovitz P, Yaacov O, Weinstein T, Hirsh J, Katz M, Gafter U (2002) Effect of increased dialysate volume on peritoneal surface area among peritoneal dialysis patients. J Am Soc Nephrol 13:2254–2259
Harris KP, Keogh AM, Alderson L (2001) Peritoneal dialysis fill volume: can the patient tell the difference? Perit Dial Int 21 (Suppl 3) S144–S147
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Fischbach, M., Terzic, J., Laugel, V. et al. Measurement of hydrostatic intraperitoneal pressure: a useful tool for the improvement of dialysis dose prescription. Pediatr Nephrol 18, 976–980 (2003). https://doi.org/10.1007/s00467-003-1199-9
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00467-003-1199-9