Abstract
Background
To minimize bleeding and biliary leakage after open hepatectomy, fibrin sealing is undertaken at the transaction plane of the liver. Recently, clinicians have begun using polyglycolic acid PGA felt as an absorbable cross-linker. However, this method has not been well studied for laparoscopic hepatectomy because available laparoscopic devices are quite limited. This study aimed to investigate the feasibility and efficacy of using fibrin sealant with PGA felt in laparoscopic hepatectomy.
Methods
A retrospective analysis of prospectively collected data from 1997 for laparoscopic hepatectomy was performed. Application of fibrin sealant with PGA felt in laparoscopic hepatectomy was begun in February 2009, and the data collected until November 2009 were used. The differences in the perioperative factors were compared including hematocrit and bilirubin concentration changes in the drainage fluid between the surgical procedures conducted with and without the use of fibrin sealant and PGA felt.
Results
Fibrin sealant with PGA felt was used in 18 patients who underwent laparoscopic hepatectomy after February 2009. The data for these patients were compared with those for 22 patients who underwent laparoscopic hepatectomy before the start of fibrin sealant use. The operative procedure and devices differed according to the period. No significant differences in preoperative factors were observed between the groups. The use of fibrin sealant had no influence on the operation time or changes in the leukocyte count or serum C-reactive protein. No cases of postoperative bleeding or biliary leakage occurred in either group, and the time course of the perioperative hematocrit and drain bilirubin concentrations did not differ between the two groups.
Conclusion
Use of fibrin sealant with PGA felt in laparoscopic hepatectomy appears to be feasible, and the outcomes are not inferior to those in the control group.
Similar content being viewed by others
References
Wakabayashi G, Nitta H, Takahara T, Shimazu M, Kitajima M, Sasaki A (2009) Standardization of basic skills for laparoscopic liver surgery towards laparoscopic donor hepatectomy. J Hepatobiliary Pancreat Surg 16:439–444
Otsuka Y, Tsuchiya M, Maeda T, Katagiri T, Isii J, Tamura A, Yamazaki K, Kubota Y, Suzuki T, Suzuki T, Kagami S, Kaneko H (2009) Laparoscopic hepatectomy for liver tumors: proposals for standardization. J Hepatobiliary Pancreat Surg 16:720–725
Sakon M, Monden M, Gotoh M, Kobayashi K, Kambayashi J, Mori T, Okamura J (1989) Use of microcrystalline collagen powder and fibrinogen tissue adhesive for hemostasis and prevention of rebleeding in patients with hepatocellular carcinoma associated with cirrhosis of the liver. Surg Gynecol Obstet 168:453–454
Cherqui D, Soubrane O, Husson E, Barshasz E, Vignaux O, Ghimouz M, Branchereau S, Chardot C, Gauthier F, Fagniez PL, Houssin D (2002) Laparoscopic living donor hepatectomy for liver transplantation in children. Lancet 359:392–396
Kobayashi S, Nagano H, Marubashi S, Wada H, Eguchi H, Takeda Y, Tanemura M, Sekimoto M, Doki Y, Mori M (2010) A single-incision laparoscopic hepatectomy for hepatocellular carcinoma: initial experience in a Japanese patient. Minim Invasive Ther Allied Technol 19:367–371
Tsuda T, Nakamura T, Yamamoto Y, Teramachi M, Kiyotani T, Lee YH, Shimizu Y (1999) Prevention of postoperative air leakage from lungs using a purified human collagen membrane-polyglycolic acid sheet. Ann Thorac Surg 68:339–342
Kato Y, Matsumoto I, Tomita S, Watanabe G (2009) A novel technique to prevent intraoperative pneumothorax in awake coronary artery bypass grafting: biomaterial neopleura. Eur J Cardiothorac Surg 35:37–41
Maniwa T, Kaneda H, Saito Y (2009) Management of a complicated pulmonary fistula caused by lung cancer using a fibrin glue-soaked polyglycolic acid sheet covered with an intercostal muscle flap. Interact Cardiovasc Thorac Surg 8:697–698
Hayashibe A, Sakamoto K, Shinbo M, Makimoto S, Nakamoto T (2006) New method for prevention of bile leakage after hepatic resection. J Surg Oncol 94:57–60
Kobayashi S, Nagano H, Marubashi S, Wada H, Eguchi H, Takeda Y, Tanemura M, Doki Y, Mori M (in press) Fibrin sealant with PGA felt for prevention of bile leakage after liver resection. Hepatogastroenterology
Dagher I, Belli G, Fantini C, Laurent A, Tayar C, Lainas P, Tranchart H, Franco D, Cherqui D (2010) Laparoscopic hepatectomy for hepatocellular carcinoma: a European experience. J Am Coll Surg 211:16–23
Kaneko H, Takagi S, Otsuka Y, Tsuchiya M, Tamura A, Katagiri T, Maeda T, Shiba T (2005) Laparoscopic liver resection of hepatocellular carcinoma. Am J Surg 189:190–194
Bryant R, Laurent A, Tayar C, Cherqui D (2009) Laparoscopic liver resection-understanding its role in current practice: the Henri Mondor Hospital experience. Ann Surg 250:103–111
Tsuchiya M, Otsuka Y, Tamura A, Nitta H, Sasaki A, Wakabayashi G, Kaneko H (2009) Status of endoscopic liver surgery in Japan: a questionnaire survey conducted by the Japanese Endoscopic Liver Surgery Study Group. J Hepatobiliary Pancreat Surg 16:405–409
Dagher I, Belli G, Fantini C, Laurent A, Tayar C, Lainas P, Tranchart H, Franco D, Cherqui D (2010) Laparoscopic hepatectomy for hepatocellular carcinoma: a European experience. J Am Coll Surg 211:16–23
Nguyen KT, Gamblin TC, Geller DA (2009) World review of laparoscopic liver resection: 2, 804 patients. Ann Surg 250:831–841
Capussotti L, Ferrero A, Viganò L, Sgotto E, Muratore A, Polastri R (2006) Bile leakage and liver resection: Where is the risk? Arch Surg 141:690–694
Nakai T, Kawabe T, Shiraishi O, Shiozaki H (2004) Prevention of bile leak after major hepatectomy. Hepatogastroenterology 51:1286–1288
Nakayama H, Masuda H, Shibata M, Amano S, Fukuzawa M (2003) Incidence of bile leakage after three types of hepatic parenchymal transection. Hepatogastroenterology 50:1517–1520
Lai EC, Tang CN, Ha JP, Li MK (2009) Laparoscopic liver resection for hepatocellular carcinoma: ten-year experience in a single center. Arch Surg 144:143–147
Zhen ZJ, Lau WY, Wang FJ, Lai EC (2010) Laparoscopic liver resection for hepatocellular carcinoma in the left liver: Pringle maneuver versus tourniquet method. World J Surg 34:314–319
Yamamoto T, Fujibayashi S, Nakajima N, Sugai H, Hyon SH, Nakamura T (2008) Biodegradable adhesive (LYDEX) with hydroxyapatite granules. Key Enginnering materials 361:575–578
Disclosures
Shogo Kobayashi, Hiroaki Nagano, Shigeru Marubashi, Hiroshi Wada, Hidetoshi Eguchi, Masahiro Tanemura, Mitsugu Sekimoto, Koji Umeshita, Yuichiro Doki, and Masaki Mori have no conflicts of interest or financial ties to disclose.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kobayashi, S., Nagano, H., Marubashi, S. et al. Experience with the use of fibrin sealant plus polyglycolic acid felt at the cut surface of the liver in laparoscopic hepatectomy. Surg Endosc 25, 3590–3596 (2011). https://doi.org/10.1007/s00464-011-1764-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00464-011-1764-4