Abstract
Background
The visual information obtained in hand-assisted laparoscopic surgery (HALS) and total laparoscopy is based on two-dimensional depth cues. This study was designed to test the hypothesis that intracorporeal hand improves depth perception in HALS.
Methods
Ten subjects were divided into two groups using HALS or total laparoscopy. The first task was passing a 10-cm thread through four small metallic loops five times; the second was tying 30 square three-throw intracorporeal laparoscopic knots. End points were (1) number of past pointing as an index of movement accuracy and reflection of depth perception, (2) execution time, and (3) knot quality score.
Results
The HALS group was significantly faster than total laparoscopy with a median (interquartile range (IQR)) of 117 s (75.5) vs. 179 s (235.5; P = 0.001) for the thread passing task and 97 s (43.3) vs. 130 s (68.3; P < 0.0005) for knot tying. The number of past-pointing events was significantly lower with HALS compared with total laparoscopy with a median (IQR) of 12 (8) vs. 23 (24; P = 0.001) for the thread passing task and 7 (5) vs. 13 (10; P < 0.0005) for knot tying. There was a significant main effect of whether the targeted object was in contact with the other instrument in knot tying task when past-pointing occurred (P = 0.031). No difference in a knot quality score was found between the HALS and total laparoscopy.
Conclusions
The accuracy of instrument movement was significantly better in the HALS group compared with total laparoscopy. The study confirmed the hypothesis that intracorporeal hand improves depth perception in HALS. Also, the touch of the assisting instrument with the target object enhances spatial orientation in the laparoscopic operative field. However, further study is needed to test the hypothesis in experts.
Similar content being viewed by others
References
Bagesteiro LB, Sarlegna FR, Sainburg RL (2006) Differential influence of vision and proprioception on control of movement distance. Exp Brain Res 171:358–370
Manasnayakorn S, Cuschieri A, Hanna GB (2008) Ideal manipulation angle and instrument length in hand-assisted laparoscopic surgery. Surg Endosc 22:924–929
Hanna GB, Shimi S, Cuschieri A (1997) Optimal port locations for endoscopic intracorporeal knotting. Surg Endosc 11:397–401
Hanna GB, Frank TG, Cuschieri A (1997) Objective assessment of endoscopic knot quality. Am J Surg 174:410–413
Lateiner JE, Sainburg RL (2003) Differential contributions of vision and proprioception to movement accuracy. Exp Brain Res 151:446–454
Scheidt RA, Conditt MA, Secco EL, Mussa-Ivaldi FA (2005) Interaction of visual and proprioceptive feedback during adaptation of human reaching movements. J Neurophysiol 93:3200–3213
Plooy A, Tresilian JR, Mon-Williams M, Wann JP (1998) The contribution of vision and proprioception to judgements of finger proximity. Exp Brain Res 118:415–420
Rao AK, Gordon AM (2001) Contribution of tactile information to accuracy in pointing movements. Exp Brain Res 138:438–445
Acknowledgment
The author thanks the Royal Thai Government for funding the scholarship for Dr Sopark Manasnayakorn.
Disclosures
Drs. Manasnayakorn, Cuschieri, and Hanna have no conflicts of interest or financial ties to disclose.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Manasnayakorn, S., Cuschieri, A. & Hanna, G.B. Hand-assisted laparoscopic surgery is associated with enhanced depth perception in novices. Surg Endosc 24, 2694–2699 (2010). https://doi.org/10.1007/s00464-010-1027-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00464-010-1027-9