Abstract
Background: Gasless laparoscopy has the advantage of avoiding the risk inherent in pneumoperitoneum, but has not gained widespread popularity because of limited exposure of the operative field. Improved retraction devices are therefore needed. Methods: A loop-shaped metallic retractor was designed for planar lifting of the anterior abdominal wall. Four types of retractor (5/6-, 3/4-, and 1/2-circle with rod at 90°, and 1/2-circle with rod at 97°) were studied in 15 pigs. The device was then used for 47 patients. Results: The 1/2-circle was the most smoothly inserted retractor and was significantly safer than the 5/6-circle (p < 0.05, Fisher’s exact probability test). The 1/2-circle with rod at 97° was utilized for clinical cases. This retractor can be readied within 1 min and was used successfully for all operations. Conclusions: This new retractor for gasless laparoscopic surgery provides good exposure and has the potential to enhance the performance of advanced laparoscopic surgery.
Similar content being viewed by others
References
S Banting S Shimi GV Velpen A Cushieri (1993) ArticleTitleAbdominal wall lift: low pressure pneumoperitoneum laparoscopic surgery. Surg Endosc 7 57–59 Occurrence Handle1:STN:280:ByyC2c3hslU%3D Occurrence Handle8424237
BS Davidson DM Cromeens BW Freig (1996) ArticleTitleAlternative methods of exposure minimize cardiopulmonary risk in experimental animals during minimally invasive surgery. Surg Endosc 10 301–304 Occurrence Handle10.1007/s004649910046 Occurrence Handle1:STN:280:BymB2s7mtlQ%3D Occurrence Handle8779063
RL Goodale DS Beebe MP McNevin M Boyle JG Letourneau JH Abrams FB Cerra (1993) ArticleTitleHemodynamic, respiratory and metabolic effects of laparoscopic cholecystectomy. Am J Surg 166 533–537 Occurrence Handle1:STN:280:ByuD2Mjit1M%3D Occurrence Handle8238748
D Glozman M Shoham A Fischer (2001) ArticleTitleA surface-matching technique for robot-assisted registration. Comput Aided Surg 6 259–269 Occurrence Handle10.1002/igs.10015 Occurrence Handle1:STN:280:DC%2BD387lvFKnsQ%3D%3D Occurrence Handle11892002
JU Hassain MJ Matjasko (1991) Practical anesthesia for laparoscopic procedures. KA Zucker RW Bailey EJ Reddick (Eds) Surgical Laparoscopy. Quality Medical Publishing Inc St. Louis, MO
D Hashimoto AS Neyeem S Kajiwara T Hashimoto (1993) ArticleTitleLaparoscopic cholecystectomy: an approach without pneumoperitoneum. Surg Endosc 7 54–56 Occurrence Handle1:STN:280:ByyC2c3hslQ%3D Occurrence Handle8424236
JO Jorgensen NJ Lalak L North K Hanel DR Hunt DL Morris (1994) ArticleTitleVenous stasis during laparoscopic cholecystectomy. Surg Laparosc Endosc 4 128–133 Occurrence Handle1:STN:280:ByuB3snjtlA%3D Occurrence Handle8180764
S Kitano M Tomikawa Y Iso . Iwata K Gondo M Moriyama K Sugimachi (1992) ArticleTitleA safe and simple method to maintain a clear field of vision during laparoscopic cholecystectomy. Surg Endosc 6 197–198 Occurrence Handle1:STN:280:By2A1M%2Fot1U%3D Occurrence Handle1387738
P Mouret (1996) ArticleTitleHow I developed laparoscopic cholecystectomy. Ann Acad Med Singapore 25 744–747 Occurrence Handle1:STN:280:ByiD1c3nvVA%3D Occurrence Handle8924020
H Nagai Y Kondo T Yasuda K Kasahara K Kanazawa (1993) ArticleTitleAn abdominal wall-lift method of laparoscopic cholecystectomy without peritoneal insufflation. Surg Laparosc Endosc 3 175–179 Occurrence Handle1:STN:280:ByuC2MvpsVI%3D Occurrence Handle8111552
H Nakamura Y Kobori N Goseki H Inoue K Takeshita M Endo T Nakamura (1996) ArticleTitleFishing-rod-type abdominal wall lifter for gasless laparoscopic surgery. Surg Endosc 10 944–946 Occurrence Handle10.1007/s004649900206 Occurrence Handle1:STN:280:ByiC2cjptFM%3D Occurrence Handle8703160
N O’Rourke PM Price S Kelly K Sikora (1993) ArticleTitleTumor inoculation during laparoscopy. Lancet 342 368 Occurrence Handle10.1016/0140-6736(93)91511-J Occurrence Handle1:STN:280:ByyA38bpsFI%3D
RS Smith WR Fry EKM Tsoi VJ Henderson ER Hirvela RH Koehler DM Brams DJ Morabito GW Peskin (1993) ArticleTitleGasless laparoscopy and conventional instruments. Arch Surg 128 1102–1107 Occurrence Handle1:STN:280:ByuD38blt1c%3D Occurrence Handle8215870
DW Weaver (1994) ArticleTitleGasless laparoscopy for complex surgical procedures. Int Surg 79 314–316 Occurrence Handle1:STN:280:ByqB38bjsV0%3D Occurrence Handle7713698
CM Wittgen CH Andrus SD Fitzgerald LJ Baudendistel TE Dahms DL Kaminski (1991) ArticleTitleAnalysis of the hemodynamic and ventilatory effects of laparoscopic cholecystectomy. Arch Surg 126 997–1001 Occurrence Handle1:STN:280:By6A387kvVI%3D Occurrence Handle1830738
BM Wolfe BN Gardiner BF Learly CF Frey (1991) ArticleTitleEndoscopic cholecystectomy: an analysis of complications. Arch Surg 126 1192–1198 Occurrence Handle1:STN:280:By2D38fjsVU%3D Occurrence Handle1834039
DI Watson G Mathew T Ellis CF Baigrie AM Rofe GG Jamieson (1997) ArticleTitleGasless laparoscopy may reduce the risk of port-site metastases following laparoscopic surgery. Arch Surg 132 166–169 Occurrence Handle1:STN:280:ByiC1MvkvVc%3D Occurrence Handle9041921