The Accutrend sensor glucose analyzer may not be adequate in bedside testing for neonatal hypoglycemia

  • Original Paper
  • Published:
European Journal of Pediatrics Aims and scope Submit manuscript

Abstract

The aim of this prospective observational study was to compare a bedside test with the reference laboratory method in routine postnatal glucose monitoring. Term newborns with increased risk or clinical signs of hypoglycemia were screened with a bedside test. In case of a glucose value below 2.25 mmol/L, a second blood sample was taken and a duplicate glucose measurement done in the laboratory using a bedside test (Accutrend sensor) and the reference laboratory method (hexokinase method) at the same time and from the same sample. From 110 term newborns, 122 blood samples were obtained for duplicate measurements (median 1.69 mmol/L, SD 0.45 mmol/L). Of these 122, Accutrend correctly identified 97% as being <2.25 mmol/L by the laboratory method. A Bland-Altman plot revealed a mean underestimation of the Accutrend of only −0.09 mmol/L. However, due to high scattering, the maximal over- and underestimation was 0.89 and 1.39 mmol/L, respectively. Only 75% of the results from the Accutrend were within ±20% of the result of the laboratory method. If the cut-off for low glucose concentrations was set 0.6 mmol/L higher for the bedside test as compared to the laboratory method, all patients except one would have been correctly identified as hypoglycemic. Conclusion: When using the Accutrend sensor, single infants with even marked hypoglycemia might be missed. Some delay in receiving accurate measurements might be more helpful for clinical decisions and long-term outcome than immediate but potentially misleading results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. American Diabetes Association (1996) Consensus statement: self-monitoring of blood glucose. Diabetes Care 19:S62–S66

    Google Scholar 

  2. Arens S, Moons V, Meuleman P, Struyf F, Zaman Z (1998) Evaluation of Glucocard Memory 2 and Accutrend sensor blood glucose meters. Clin Chem Lab Med 36:47–52

    Article  PubMed  CAS  Google Scholar 

  3. Bland JM, Altman DG (1995) Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 346:1085–1087

    Article  PubMed  CAS  Google Scholar 

  4. Bonacruz GL, Arnold JD, Leslie GI, Wyndham L, Koumantakis G (1996) Survey of the definition and screening of neonatal hypoglycemia in Australia. J Paediatr Child Health 32:299–301

    PubMed  CAS  Google Scholar 

  5. Cornblath M, Hawdon JM, Williams AF, Aynsley-Green A, Ward-Platt MP, Schwartz R, Kalhan SC (2000) Controversies regarding definition of neonatal hypoglycemia: suggested operational thresholds. Pediatrics 105:1141–1145

    Article  PubMed  CAS  Google Scholar 

  6. Cowett RM, Loughead JL (2002) Neonatal glucose metabolism: differential diagnoses, evaluation, and treatment of hypoglycemia. Neonatal Netw 21:9–19

    PubMed  Google Scholar 

  7. Duvanel CB, Fawer C-L, Cotting J, Hohlfeld P. Matthieu J-M (1999) Long-term effects of neonatal hypoglycemia on brain growth and psychomotor development in small-for-gestational-age preterm infants. J Pediatr 134:492–498

    Article  PubMed  CAS  Google Scholar 

  8. Girouard J, Forest JC, Masse J, Leroux M (2000) Multicenter evaluation of the glucometer elite XL meter, an instrument specifically designed for use with neonates. Diabetes Care 23:1149–1153

    Article  PubMed  CAS  Google Scholar 

  9. Gregory JW, Aynsley-Green A (1993) The definition of hypoglycemia. Baillière's Clin Endocrinol Metab 7:587–590

    Article  CAS  Google Scholar 

  10. Hamid MH, Chishti AL, Maqbool S (2004) Clinical utility and accuracy of a blood glucose meter for the detection of neonatal hypoglycemia. J Coll Physicians Surg Pak 14:225–228

    PubMed  Google Scholar 

  11. Ho HT, Yeung WKY, Young BWY (2004) Evaluation of “point of care” devices in the measurement of low blood glucose in neonatal practice. Arch Dis Child Fetal Neonatal Ed 89:F356–359

    Article  PubMed  CAS  Google Scholar 

  12. Fogh-Andersen N, D'Orazio P, Kuwa K,Külpmann W, Mager G, Larsson L (2000) Recommendation on reporting results for blood glucose. eJIFCC 12(4), http://www.ifcc.org/ejifcc/vol12no4/vol12no4a4.htm. Cited 18 September 2005

  13. Innanen VT, DeLand ME, deCampos FM, Dunn MS (1997) Point-of-care glucose testing in the neonatal intensive care unit is facilitated by the use of the Ames Glucometer Elite electrochemical glucose meter. J Pediatr 130:151–155

    Article  PubMed  CAS  Google Scholar 

  14. Leonard M, Chessall M, Manning D (1997) The use of a Hemocue blood glucose analyzer in a neonatal unit. Ann Clin Biochem 34:287–290

    PubMed  Google Scholar 

  15. Lucas A, Morley R, Cole TJ (1988) Adverse neurodevelopmental outcome of moderate neonatal hypoglycemia. BMJ 297:1304–1308

    Article  PubMed  CAS  Google Scholar 

  16. Passing H, Bablok W (1984) A new biometrical method for testing the equality of measurements from two different analytical methods. J Clin Chem Biochem 22:431–435

    CAS  Google Scholar 

  17. Raile K, Simbruner G (1998) The Hemocue B glucose analyser and neonatal blood glucose monitoring. Ann Clin Biochem 35:329–330

    PubMed  Google Scholar 

  18. Schlebusch H, Niesen M, Sorger M, Paffenholz I, Fahnenstich H (1998) Blood glucose determinations in newborns: four instruments compared. Pediatr Pathol Lab Med 18:41–48

    Article  PubMed  CAS  Google Scholar 

  19. Schrier AM, Wilhelm PB, Church RM, Povar ML, Schrier JE, Sehgal PK et al (1990) Neonatal hypoglycemia in the Rhesus monkey: effect on development and behavior. Infant Behav Dev 13:189–208

    Article  Google Scholar 

  20. Williams AF (1997) Hypoglycaemia of the newborn. Review of the literature. World Health Organization, Geneva. http://www.who.int/child-adolescent-health/New_Publications/NUTRITION/WHO_CHD_97.1.pdf

Download references

Acknowledgements

We are grateful to all infants and their parents who took part in this study as well as to all nurses, doctors, and lab technicians for their help and support, and to Dr B. Rolinski for critical reading of the manuscript. The study was not supported by any company.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Helmut Küster.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rosenthal, M., Ugele, B., Lipowsky, G. et al. The Accutrend sensor glucose analyzer may not be adequate in bedside testing for neonatal hypoglycemia. Eur J Pediatr 165, 99–103 (2006). https://doi.org/10.1007/s00431-005-0013-z

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00431-005-0013-z

Keywords

Navigation