Cytologic features of a pleural effusion after silicone breast implant rupture

  • Brief Report
  • Published:
Virchows Archiv Aims and scope Submit manuscript

Abstract

Pleural effusion is an extremely rare complication of ruptured breast silicone implants. Rupture may be related to a recent trauma or occur spontaneously, making its diagnosis more difficult. In the few reported cases, cytology did not play a relevant role in its diagnosis. We describe and illustrate a silicone foreign body reaction in a pleural effusion. Cytologic findings were so remarkable as to permit a specific diagnosis. The patient, a 37-year-old female with a history of previous bilateral breast implant surgery was admitted because of a pleural effusion. Computed tomography scan showed a left effusion with secondary atelectasis and bilateral breast rupture with lymph node “siliconomas.” Cytologic analysis of the effusion showed well-defined droplets or globules of transparent material, in addition to a microvacuolized background. Where abundant silicone droplets induced a staining artifact of the smears. These were cellular with numerous macrophages containing large vacuoles displacing the nuclei to the periphery. Some had a signet cell ring appearance, while others showed multinucleation. Flow cytometry revealed a predominant macrophagic cell population. With the increasing use of silicone breast implants, rare complications such as pleural effusion may become more common. The pathologist must consider this possibility when extracellular transparent droplets or evidence of a foreign body-type reaction are present. The artifact appearance of the smears may help to suspect it. This rare complication must be always considered when evaluating effusions in patients with silicone breast implants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Data availability

All data and materials available.

Code availability

Not applicable.

References

  1. Medeiros LJ (2021) Silicone lymphadenopathy. Ioachim’s lymph node pathology, 4th edn. Wolters Kluwer Health, Philadelphia, pp 334–337

    Google Scholar 

  2. Dragu A, Theegarten D, Bach AD, Polykandriotis E, Arkudas A, Kneser U, Horch RE, Ingianni G (2009) Intrapulmonary and cutaneous siliconomas after silent silicone breast implant failure. Breast J 15:496–499. https://doi.org/10.1111/j.1524-4741.2009.00765.x

    Article  PubMed  Google Scholar 

  3. Stevens WM, Burdon JG, Niall JF (1987) Pleural effusion after rupture of silicone bag mammary prosthesis. Thorax 42:825–826. https://doi.org/10.1136/thx.42.10.825

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  4. Taupmann RE, Adler S (1993) Silicone pleural effusion due to iatrogenic breast implant rupture. South Med J 86:570–571. https://doi.org/10.1097/00007611-199305000-00017

    Article  CAS  PubMed  Google Scholar 

  5. Hirmand H, Hoffman LA, Smith JP (1994) Silicone migration to the pleural space associated with silicone-gel augmentation mammaplasty. Ann Plast Surg 32:645–647. https://doi.org/10.1097/00000637-199406000-00015

    Article  CAS  PubMed  Google Scholar 

  6. Shaik IH, Gandrapu B, Gonzalez-Ibarra F, Flores D, Matta J, Syed AK (2015) Silicone breast implants: a rare cause of pleural effusion. Case Rep Pulmonol 2015:652918. https://doi.org/10.1155/2015/652918

    Article  PubMed Central  PubMed  Google Scholar 

  7. Marchiori E, Camargo S, Hochhegger B (2019) Silicone thorax: another complication of breast prosthesis rupture. Arch Bronconeumol (Engl Ed) 55:172–173. https://doi.org/10.1016/j.arbres.2018.08.001

    Article  PubMed  Google Scholar 

  8. Fanelli B, Marcasciano M, Lovero S, Codolini L, Casella D, Onesti MG, Ribuffo D, Scuderi N (2021) Thoracic migration of silicone gel after breast implant rupture: a case report and literature review. Eur J Plast Surg 44:835–842. https://doi.org/10.1007/s00238-021-01799-0

    Article  Google Scholar 

  9. Hudacko R, Anand K, Gordon R, John T, Catalano C, Zaldana F, Katz HJ, Fyfe B, Rustgi V (2019) Hepatic silicone granulomas secondary to ruptured breast implants: a report of two cases. Case Reports Hepatol 2019:7348168. https://doi.org/10.1155/2019/7348168

    Article  PubMed Central  PubMed  Google Scholar 

  10. Mayl JJ, Flores MA, Stelzer JW, Liu B, Messina SA, Murray JV (2018) Recognizing intraventricular silicone. Emerg Radiol 25:215–218. https://doi.org/10.1007/s10140-018-1582-2

    Article  PubMed  Google Scholar 

  11. Tabatowski K, Elson CE, Johnston WW (1990) Silicone lymphadenopathy in a patient with a mammary prosthesis. Fine needle aspiration cytology, histology and analytical electron microscopy. Acta Cytol 34:10–14

    CAS  PubMed  Google Scholar 

  12. Raso DS, Greene WB, Vesely JJ, Willingham MC (1994) Light microscopy techniques for the demonstration of silicone gel. Arch Pathol Lab Med 118:984–987 (PMID: 7944900)

    CAS  PubMed  Google Scholar 

  13. Sahn SA (1998) Malignancy metastatic to the pleura. Clin Chest Med 19:351–361. https://doi.org/10.1016/s0272-5231(05)70082-4

    Article  CAS  PubMed  Google Scholar 

  14. D’Alessandris N, Lucatelli P, Tripodi D, Amabile MI, Ascoli V (2019) Cytological features of breast implant-associated anaplastic large cell lymphoma in pleural effusion. Diagn Cytopathol 47:1213–1217. https://doi.org/10.1002/dc.24287

    Article  PubMed  Google Scholar 

  15. Muñoz-Hernández P, Serrano-Pardo R, Bárcena C, Jiménez-Heffernan JA (2021) Cytoplasmic vacuolization in breast implant-associated anaplastic large-cell lymphoma. Diagn Cytopathol 49:549–551. https://doi.org/10.1002/dc.24712

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Contributions

JAJ-H: pathologic diagnosis, conceptualization, literature review, and writing of the manuscript. AR: pathologic diagnosis and writing of the manuscript. EV-E: clinical diagnosis and literature review. CI-O: radiologic diagnosis, data analysis and literature review. MS-G: clinical diagnosis, and editing of the text. EP: conceptualization, radiologic diagnosis, data analysis, and editing of the text.

Corresponding author

Correspondence to José A. Jiménez-Heffernan.

Ethics declarations

Ethics approval

This paper was conducted ethically, in accordance with the World Medical Association Declaration of Helsinki. For single case reports, no ethical approval is necessary from the Ethics Committee of the University Hospital La Princesa, Madrid, Spain.

Consent to participate/for publication

The patient gave written informed consent to publication of this case, and her data have been anonymized throughout the publication process.

Conflict of interest

The authors declare no competing interests.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jiménez-Heffernan, J.A., Rosell, A., Vázquez-Espinosa, E. et al. Cytologic features of a pleural effusion after silicone breast implant rupture. Virchows Arch 482, 1065–1068 (2023). https://doi.org/10.1007/s00428-022-03425-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00428-022-03425-1

Keywords

Navigation