Indicators and optical configuration for simultaneous high-resolution recording of membrane potential and intracellular calcium using laser scanning microscopy

  • Instruments and Techniques
  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Abstract

 The instrumental design and experimental conditions for high-speed, simultaneous optical recording of membrane potential and intracellular Ca2+ with subcellular resolution are presented. This method employs an extended version of a high-speed, random-access, laser-scanning fluorescence microscope designed to record fast physiological signals from small neuronal structures with high spatiotemporal resolution (Bullen, Patel, Saggau, Biophys J 73:477–491, 1997). With this instrument, imaging and optical recording functions are conducted separately allowing frame rates up to 3 kHz. Individual scanning points are selected interactively from a reference image collected with differential interference contrast (DIC) optics. At each recording site, fluorescence from two indicators is measured simultaneously by independent photodetectors. To optimize signal strength, spectral separation and the achievable signal-to-noise ratio, several combinations of voltage-sensitive dye, Ca2+ indicator and optical elements (dichroic mirrors, filters, etc.) were considered. The best results were achieved from the combination of the intracellular voltage-sensitive dye Di-2-ANEPEQ and the Ca2+ indicator Calcium Green-1. These indicators have overlapping absorption spectra allowing simultaneous excitation with a single laser line (488 nm). Spectral separation of the fluorescence from these two indicators was accomplished using a secondary dichroic mirror (DCLP580) and emission filters (535/45 and OG590). Representative records obtained with this instrument and this combination of indicators demonstrate the feasibility of simultaneous high fidelity measurements of membrane potential and intracellular Ca2+ from the same point at high spatial (2 µm) and temporal (<ms) resolution without requiring signal averaging.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 22 January 1998 / Accepted: 5 May 1998

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bullen, A., Saggau, P. Indicators and optical configuration for simultaneous high-resolution recording of membrane potential and intracellular calcium using laser scanning microscopy. Pflügers Arch 436, 788–796 (1998). https://doi.org/10.1007/s004240050703

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004240050703

Navigation