Skip to main content

Advertisement

Log in

Rectal transection using a curved cutter stapler with an endo-Satinsky clamp during a laparoscopic low anterior resection

  • How-I-Do-It Article
  • Published:
Langenbeck's Archives of Surgery Aims and scope Submit manuscript

Abstract

Purpose

A new rectal transaction method was developed using a combination of the curved cutter stapler and endo-Satinsky clamp because of the difficulty in performing rectal transection in the narrow pelvic cavity.

Methods

The endo-Satinsky clamp is inserted without a flexible trocar cannula by connecting the handle extra-abdominally with a shaft of the endo-Satinsky clamp through the left higher quadrant port via a retrograde course from a midline incision above the pubis symphysis. The endo-Satinsky clamp is used to clamp the rectal wall horizontally at the distal end of the tumor. The wrist of an elastic surgical glove fixed with the shaft of the curved cutter stapler is covered with a midline incision, and consequently, the stapler is inserted into the pelvic cavity. The curved head of the stapler is rotated to the left at the anal side of the endo-Satinsky clamp to insert the rectum between the jaws of the stapler. The stapler is closed and fired, and a rectal transection is thus performed with one firing using a single cartridge.

Results

This method was performed in 12 patients with rectal cancer. The median value and range of the tumor distance from the anal verge were 7.0 and 4.5–11.0 cm, respectively. The median duration of the operation was 252 min, and the median blood loss was 15 mL. Only one stapling cartridge was used for rectal transection in all cases, and no major complications were observed.

Conclusions

We herein demonstrated a new transection method for rectal cancer.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  1. Kuroyanagi H, Akiyoshi T, Oya M et al (2009) Laparoscopic-assisted anterior resection with double-stapling technique anastomosis: safe and feasible for lower rectal cancer? Surg Endosc 23:2197–2202

    Article  PubMed  Google Scholar 

  2. Ito M, Sugito M, Kobayashi A, Nishizawa Y, Tsunoda Y, Saito N (2008) Relationship between multiple numbers of stapler firings during rectal division and anastomotic leakage after laparoscopic rectal resection. Int J Colorectal Dis 23:703–707

    Article  PubMed  Google Scholar 

  3. Hotta T, Takifuji K, Yokoyama S et al (2011) Rectal transection by the Nelaton catheter pulling method during a laparoscopic low anterior resection. Dis Colon Rectum 54:495–500

    Article  PubMed  Google Scholar 

  4. Ishii Y, Hasegawa H, Nishibori H, Endo T, Kitajima M (2006) The application of a new stapling device for open surgery (Contour Curved Cutter Stapler) in the laparoscopic resection of rectal cancer. Surg Endosc 20:1329–1331

    Article  PubMed  CAS  Google Scholar 

  5. Targarona EM, Balague C, Martinez C, Hernandez MP, Trias M (2008) Laparoscopic low rectal anastomosis using a new stapling device: early experience with the Contour stapler. Minim Invasive Ther Allied Technol 17:155–159

    Article  PubMed  CAS  Google Scholar 

  6. Park SJ, Choi SI, Lee SH, Lee KY (2010) Endo-satinsky clamp for rectal transection during laparoscopic total mesorectal excision. Dis Colon Rectum 53:355–359

    Article  PubMed  Google Scholar 

  7. Cancer Institute (NCI), Cancer Therapy Evaluation Program (2009) Common Terminology Criteria for Adverse Events v4.0 (CTCAE). http://ctep.cancer.gov/protocolDevelopment/electronic_applications/ctc.htm#ctc_40

  8. Kodeda K, Holmberg E, Jörgren F, Nordgren S, Lindmark G (2010) Rectal washout and local recurrence of cancer after anterior resection. Br J Surg 97:1589–1597

    Article  PubMed  CAS  Google Scholar 

  9. Hamada M, Nishioka Y, Kurose Y et al (2007) New laparoscopic double-stapling technique. Dis Colon Rectum 50:2247–2251

    Article  PubMed  Google Scholar 

Download references

Conflicts of interest

Drs. Tsukasa Hotta, Katsunari Takifuji, Shozo Yokoyama, Kenji Matsuda, and Hiroki Yamaue have no conflicts of interest or financial ties to disclose.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hiroki Yamaue.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hotta, T., Takifuji, K., Yokoyama, S. et al. Rectal transection using a curved cutter stapler with an endo-Satinsky clamp during a laparoscopic low anterior resection. Langenbecks Arch Surg 397, 1149–1155 (2012). https://doi.org/10.1007/s00423-012-0955-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00423-012-0955-3

Keywords

Navigation