Skip to main content
Log in

Reliability of an electrophoretic and image processing analysis of human skeletal muscle taken from m. vastus lateralis

  • ORIGINAL ARTICLE
  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Abstract

The relative content of myosin heavy chain (MHC) isoforms IIb, IIa and I in human skeletal muscle taken from the m. vastus lateralis of 30 healthy male subjects was analysed using mini-gel electrophoresis. Repeated electrophoretic gels utilizing the same methods were produced for all subjects and the determination of MHC protein bands was performed using a digital scanner and National Institutes of Health (NIH) Image software and laser densitometry. A comparison between the NIH Image processing technique and laser densitometry revealed differences of 6.47%, 6.35% and 6.84% between these measurement techniques for MHC-IIb, -IIa and -I isoforms, respectively. The percentage technical error of measurement (TEM%) between electrophoretic gels was shown to be 19.1%, 17.8% and 14.2%, with regard to percentage of occurrence of MHC-IIb, -IIa and -I isoforms respectively. The variation in electrophoretic gel analyses was shown to be 5.7%, 7.3% and 5.5%, with regard to the percentage of MHC-IIb, -IIa and -I isoforms respectively. Intra-class correlations comparing NIH Image and laser densitometry produced r values in the range 0.38–0.63. Comparisons between and within gel analyses produced r values in the range 0.59–0.94 and 0.93–0.98, respectively. Analyses of variance revealed no significant differences (P < 0.05) between analysis techniques, between␣gels or within gels for the measurement of MHC-IIb, -IIa and -I isoforms. The inter-gel error between fibre subgroups was moderate for the two type-II MHC populations and less for type-I MHC; the intra-individual error in the measuring technique used for classifying the MHC-IIb, -IIa and -I protein bands was small. The results obtained in this investigation showed consistent trends which may reflect a false classification of the type-II MHC populations for the inter-gel and intra-individual analyses. The NIH Image software and digitizing process was shown to be a valid and reliable method for distinguishing between MHC protein bands of human skeletal tissue as separated by mini-gel electrophoretic techniques.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Accepted: 6 January 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Humphries, B., Abernethy, P., Blake, K. et al. Reliability of an electrophoretic and image processing analysis of human skeletal muscle taken from m. vastus lateralis. Eur J Appl Physiol 75, 532–536 (1997). https://doi.org/10.1007/s004210050200

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004210050200

Navigation