Abstract
Purpose
Cephalic hemodynamic assessment is important in initial orthostatic hypotension. We sought to investigate cephalic blood flow (CBF) in the earlobe using a mini laser Doppler flowmeter (LDF) during orthostatic challenge. In addition, we clarified hemodynamic differences during a new active standing protocol using a footstool standing test (FST) with bending of the legs on the footstool in the sitting position to reduce the load of the squatting posture in the conventional squat standing test (SST).
Methods
Ten healthy men (21 ± 0.5 years) performed the SST after a 1 min squat and the FST after a 1 min load consisting of bending the legs on a footstool in the sitting position. Earlobe CBF, beat-to-beat arterial blood pressure (ABP), mean arterial blood pressure (MAP), and heart rate (HR) were recorded during each test.
Results
Earlobe CBF showed a transient fall synchronized with the ABP during each test. No significant differences in the recovery times (RTs) of CBF and MAP were observed during the SST (CBF 12.9 ± 0.6 s vs. MAP 12.1 ± 0.5 s, P = 0.313) and FST (CBF 10.6 ± 0.4 s vs. MAP 10.1 ± 0.8 s, P = 0.552). Although the CBF and ABP decreases were not different in each test, the HR increase was significantly lower with the FST (24 ± 2 bpm) than with the SST (31 ± 3 bpm, P < 0.005).
Conclusions
Earlobe CBF reflects the compensatory ABP regulatory response during standing and is potentially useful for estimating the orthostatic ABP response indirectly. Furthermore, the FST is a low-load protocol that can be an effective protocol for a standing test of cardiac function.
Similar content being viewed by others
Abbreviations
- ABP:
-
Arterial blood pressure
- BF:
-
Blood flow
- CBF:
-
Cephalic blood flow
- CO:
-
Cardiac output
- DT:
-
Decrease time
- FST:
-
Footstool standing test
- HR:
-
Heart rate
- HUT:
-
Head-up tilt
- IOH:
-
Initial orthostatic hypotension
- IT:
-
Increase time
- LDF:
-
Laser Doppler flowmeter
- MAP:
-
Mean arterial blood pressure
- RT:
-
Recovery time
- SST:
-
Squat standing test
- SFR:
-
Sympathetic flow response
- SV:
-
Stroke volume
- TPR:
-
Total peripheral resistance
References
Aaslid R, Markwalder TM, Nornes H (1982) Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg 57:769–774
Barantke M, Krauss T, Ortak J, Lieb W, Reppel M, Burgdorf C, Pramstaller P, Schunkert H, Bonnemeier H (2008) Effects of gender and aging on differential autonomic responses to orthostatic maneuvers. J Cardiovasc Electrophysiol 19:1296–1303
Bonner R, Nossal R (1981) Model for laser Doppler measurements of blood flow in tissue. Appl Opt 20:2097–2107
Borst C, van Brederode J, Wieling W, van Montfrans G, Dunning AJ (1984) Mechanisms of initial blood pressure response to postural change. Clin Sci (Lond) 67:321–327
Borst C, Wieling W, van Brederode J, Hond A, de Rijk L, Dunning A (1982) Mechanisms of initial heart rate response to postural change. Am J Physiol 243:H676–H681
Convertino V, Tripp LD, Ludwig DA, Duff J, Chelette TL (1998) Female exposure to high G: chronic adaptations of cardiovascular functions. Aviat Space Environ Med 69:875–882
de Mul FFM, van Spijker J, van der Plas D, Greve J, Aarnoudse J, Smits T (1984) Mini laser-Doppler (blood) flow monitor with diode. Appl Opt 23:2970–2973
Hilz M (2002) Assessment and evaluation of hereditary sensory and autonomic neuropathies with autonomic and neurophysiological examinations. Clin Auton Res 12:133–143
Imholz BP, Settels JJ, van der Meiracker AH, Wesseling KH, Wieling W (1990) Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure. Cardiovasc Res 24:214–221
Lipsitz L (1989) Orthostatic hypotension in the elderly. N Engl J Med 321:952–957
Low P, Neumann C, Dyck P, Fealey R, Tuck R (1983) Evaluation of skin vasomotor reflexes by using laser Doppler velocimetry. Mayo Clin Proc 58:583–592
Obeid AN, Barnett NJ, Dougherty G, Ward G (1990) A critical review of laser Doppler flowmetry. J Med Eng Technol 14:178–181
Oimomi M, Nishimoto S, Matsumoto S, Hatanaka H, Ishikawa K, Baba S (1985) Evaluation of periflux blood flow measurement in diabetic patients with autonomic neuropathy. Diabetes Res Clin Pract 1:81–85
Peuker ET, Filler TJ (2002) The nerve supply of the human auricle. Clin Anat 15:35–37
Philips JC, Scheen AJ (2011) Squatting test: a posture to study and counteract cardiovascular abnormalities associated with autonomic dysfunction. Auton Neurosci 162:3–9
Rickards CA, Newman DG (2003) A comparative assessment of two techniques for investigating initial cardiovascular reflexes under acute orthostatic stress. Eur J Appl Physiol 90:449–457
Rossberg F, Penaz J (1988) Initial cardiovascular response on change of posture from squatting to standing. Eur J Appl Physiol Occup Physiol 57:93–97
Rowell L (1993) Human cardiovascular control. Oxford University Press, New York, pp 443–444
Scheen AJ, Philips JC (2012) Squatting test a dynamic postural manoeuvre to study baroreflex sensitivity. Clin Aut Res 22:35–41
Serov AN, Nieland J, Oosterbaan S, de Mul FFM, van Kranenburg H, Bekman HHPT, Steenbergen W (2006) Integrated optoelectronic probe including a vertical cavity surface emitting laser for laser Doppler perfusion monitoring. IEEE Trans Biomed Eng 53:2067–2074
Shi X, Huang G, Smith S, Zhang R, Formes K (2003) Aging and arterial blood pressure variability during orthostatic challenge. Gerontology 49:279–286
Sprangers R, Wesseling K, Imholz A, Imholz B, Wieling W (1991) Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance. J Appl Physiol 70:523–530
Tanaka H, Sjöberg BJ, Thulesius O (1996) Cardiac output and blood pressure during active and passive standing. Clin Physiol 16:157–170
Thomas KN, Cotter JD, Galvin SD, Williams MJA, Willie CK, Ainslie PN (2009) Initial orthostatic hypotension is unrelated to orthostatic tolerance in healthy young subjects. J Appl Physiol 107:506–517
Thrasher TN (2005) Baroreflex control of sodium excretion and arterial pressure baroreceptors, baroreceptor unloading, and the long-term control of blood pressure. Am J Physiol Regul Integr Comp Physiol 288:R819–R827
Toska K, Eriksen M, Walløe L (1994) Short-term cardiovascular responses to a step decrease in peripheral conductance in humans. Am J Physiol 266:H199–H211
Tschakovsky ME, Matusiak K, Vipond C, McVicar L (2011) Lower limb-localized vascular phenomena explain initial orthostatic hypotension upon standing from squat. Am J Physiol Heart Circ Physiol 301:H2102–H2112
Vaddadi G, Lambert E, Corcoran SJ, Esler MD (2007) Postural syncope: mechanisms and management. Med J Aust 187:299–304
Van der Velde N, van den Meiracker AH, Stricker BHC, van der Cammen TJM (2007) Measuring orthostatic hypotension with the Finometer device: is a blood pressure drop of one heartbeat clinically relevant? Blood Press Monit 12:167–171
Wieling W, Harms M, ten Harkel A, van Lieshout J, Sprangers R (1996) Circulatory response evoked by a 3 s bout of dynamic leg exercise in humans. J Physiol 494:601–611
Wieling W, Krediet CTP, van Dijk N, Linzer M, Tschakovsky ME (2007) Initial orthostatic hypotension: review of a forgotten condition. Clin Sci (Lond) 112:157–165
Yamaguchi H, Tanaka H, Adachi K, Mino M (1996) Beat-to-beat blood pressure and heart rate responses to active standing in Japanese children. Acta Paediatr 85:577–583
Acknowledgments
The authors wish to sincerely thank the subjects for their interest and cooperation.
Conflict of interest
Financial support of collaboration for this study was provided by the Pioneer Corporation. M. Goma and Y. Kimura are employed by Pioneer Corporation.
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Author information
Authors and Affiliations
Corresponding author
Additional information
Communicated by Massimo Pagani.
Rights and permissions
About this article
Cite this article
Goma, M., Kimura, Y., Shimura, H. et al. Orthostatic response of cephalic blood flow using a mini laser Doppler blood flowmeter and hemodynamics of a new active standing test. Eur J Appl Physiol 115, 2167–2176 (2015). https://doi.org/10.1007/s00421-015-3197-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00421-015-3197-6