Skip to main content

On the method of fitting cardiac output kinetics in severe exercise

Abstract

The kinetic responses of oxygen uptake (\( \dot{V}O_{2} \)) and cardiac output (\( \dot{Q} \)) describe the rate at which these physiological variables approach the required steady state value with work rate transitions. In this issue of the Journal, Adami and colleagues examined the kinetic responses during the transition to severe intensity exercise (metabolic demands exceeding maximal \( \dot{V}O_{2} \)). Two methods were described for fitting \( \dot{V}O_{2} \) kinetics: one was an exponential model that referenced the time course of \( \dot{V}O_{2} \) relative to an apparent plateau while the second examined the rate of change with respect to the value predicted to be 120% of maximal \( \dot{V}O_{2} \). The rate of change of the primary adaptive component described by the time constant (tau2) was considerably slower when referenced to the predicted \( \dot{V}O_{2} \) (62.5 s) than when fit by the exponential model (20.3 s). For the description of \( \dot{Q} \) kinetics Adami and colleagues fitted only the exponential model. We investigated the impact of fitting the kinetics of \( \dot{Q} \) relative to a predicted value for this severe work rate as was done for \( \dot{V}O_{2} \). The time course for \( \dot{Q} \) was reconstructed from their group mean fitting parameters then referenced to values for the required \( \dot{Q} \) based on the literature. The estimate for the time constant (tau2) exceeded the value determined from the exponential model in which the curve fit was referenced to an apparent plateau by more than sixfold (86.4 s vs. 13.5 s). This outcome suggests that future investigations should explore further the dynamic interactions of metabolic regulatory factors and the limitations of the O2 supply system when describing the system kinetics.

This is a preview of subscription content, access via your institution.

Fig. 1
Fig. 2
Fig. 3

References

  • Adami A, Pogliaghi S, DeRoia G, Capelli C (2010) Oxygen uptake, cardiac output and muscle deoxygenation at the onset of moderate and supra maximal exercise in humans. Eur J Appl Physiol

  • Astrand PO, Cuddy TE, Saltin B, Stenberg J (1964) Cardiac output during submaximal and maximal work. J Appl Physiol 19:268–274

    PubMed  CAS  Google Scholar 

  • Hughson RL (2009) Oxygen uptake kinetics: historical perspective and future directions. Appl Physiol Nutr Metab 34:840–850

    PubMed  Article  CAS  Google Scholar 

  • Hughson RL, O’Leary DD, Betik AC, Hebestreit H (2000) Kinetics of oxygen uptake at the onset of exercise near or above peak oxygen uptake. J Appl Physiol 88:1812–1819

    PubMed  CAS  Google Scholar 

  • Linnarsson D (1974) Dynamics of pulmonary gas exchange and heart rate changes at start and end of exercise. Acta Physiol Scand Suppl Suppl.415:1–68

    Google Scholar 

  • Stringer WW, Whipp BJ, Wasserman K, Porszasz J, Christenson P, French WJ (2005) Non-linear cardiac output dynamics during ramp-incremental cycle ergometry. Eur J Appl Physiol 93:634–639

    PubMed  Article  Google Scholar 

  • Whipp BJ, Wasserman K (1972) Oxygen uptake kinetics for various intensities of constant-load work. J Appl Physiol 33:351–356

    PubMed  CAS  Google Scholar 

Download references

Author information

Affiliations

Authors

Corresponding author

Correspondence to Richard L. Hughson.

Additional information

Communicated by Susan A. Ward.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Hughson, R.L., Faisal, A. On the method of fitting cardiac output kinetics in severe exercise. Eur J Appl Physiol 111, 1529–1531 (2011). https://doi.org/10.1007/s00421-010-1787-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00421-010-1787-x

Keywords

  • Oxygen uptake
  • Cardiac output
  • Exponential curve fitting
  • Nonlinear response