Skip to main content
Log in

The relationship between total tear protein concentrations determined by different methods and standards

  • Clinical Investigation
  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract 

Background: It is known that the values of total protein concentration (TPC) of human tears obtained by different methods/standards vary considerably. The variations are due to differences in reactivity of proteins to the methods used. The aim of this study was to investigate the relationships and agreements between TPC values obtained by different methods/ standards. Methods: Two experiments were conducted. In experiment 1, 30 normal subjects were recruited and their TPC were determined by the Bradford and the modified Lowry methods, with bovine serum albumin and bovine immunoglobulin G as standards. The relationships (equations) between TPC values obtained by different methods/standards were determined. In experiment 2, another 15 normal subjects were recruited and the TPC were measured as in experiment 1. Measured values of TPC using different methods/standards were compared with their respective values calculated from the equations defined in experiment 1. The agreement and the reliability between the measured and the calculated values were investigated. Results: Experiment 1 showed that the TPC obtained by different methods/standards were strongly correlated to one another, and their relationships can be defined by linear equations. In experiment 2, the measured and the calculated values, using the equations defined in experiment 1, showed good agreement and reliability. This indicates that TPC obtained by one method/standard can be used to estimate the value(s) that would be obtained if another method/standard were used using the equation(s) found in experiment 1. Conclusion: The correlations between TPC values obtained by different methods/standards were strong. Our results also indicated good agreement and reliability between measured and calculated TPC values. Therefore, values obtained by different methods/standards are interchangeable using the appropriate equations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 13 September 1999 Revised: 17 February 2000 Accepted: 22 February 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ng, V., Cho, P. The relationship between total tear protein concentrations determined by different methods and standards. Graefe's Arch Clin Exp Ophthalmol 238, 571–576 (2000). https://doi.org/10.1007/s004170000147

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004170000147

Keywords

Navigation