Pulse waveform analysis in the optic nerve head circulation reflects systemic vascular resistance obtained via a Swan–Ganz catheter

  • Neurophthalmology
  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract

Purpose

To determine whether a pulse waveform analysis in the optic nerve head (ONH) circulation as determined by laser speckle flowgraphy (LSFG) can provide systemic hemodynamic values — the systemic vascular resistance (SVR) in particular — similar to those obtained by using a Swan–Ganz catheter, which is an invasive method.

Method

Sixteen consecutive subjects were examined. Hemodynamic monitoring was obtained from right heart catheterization with a Swan–Ganz catheter and coronary angiography without an intracoronary nitroglycerin administration. Direct blood pressure was measured with a trans-radial approach. Single regression analyses were used to determine the relationship between the blowout score and blowout time, which are the items of the pulse waveform analysis in the ONH, by using LSFG and the hemodynamic parameters.

Results

The blowout time was significantly and negatively correlated with the SVR (r = −0.52, p = 0.04), the ocular perfusion pressure with the mean arterial blood pressure of the radial artery (r = −0.52, p = 0.04) and the radial artery pulse pressure (r = −0.52, p = 0.04).The pulmonary capillary wedge pressure (r  = −0.44, p = 0.09) and the mean arterial blood pressure of the radial artery (r  = −0.44, p = 0.09) tended to be correlated with the blowout time, but did not reach significance. The blowout score was significantly and negatively correlated with the radial artery blood pressure (r = −0.51, p = 0.046).

Conclusion

A pulse waveform analysis in the ONH by LSFG may be one of the useful methods for understanding the SVR.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Weber KT, Janicki JS, Hunter WC, Shroff S, Pearlman ES, Fishman AP (1982) The contractile behavior of the heart and its functional coupling to the circulation. Prog Cardiovasc Dis 24:375–400

    Article  CAS  PubMed  Google Scholar 

  2. O'Rourke MF (1982) Vascular impedance in studies of arterial and cardiac function. Physiol Rev 62:570–623

    PubMed  Google Scholar 

  3. Gould KL, Lipscomb K, Hamilton GW, Kennedy JW (1974) Relation of left ventricular shape, function and wall stress in man. Am J Cardiol 34:627–634

    Article  CAS  PubMed  Google Scholar 

  4. Weber KT, Janicki JS (1980) The dynamics of ventricular contraction: force, length, and shortening. Fed Proc 39:188–195

    CAS  PubMed  Google Scholar 

  5. Sorensen MB, Bille-Brake NE, Engell HC (1976) Cardiac output measurement by thermal dilution: reproducibility and comparison with the dye-dilution technique. Ann Surg 183:67–72

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  6. Ganz W, Donoso R, Marcus HS, Forrester JS, Swan HJ (1971) A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol 27:392–396

    Article  CAS  PubMed  Google Scholar 

  7. Ganz W, Swan HJ (1972) Measurement of blood flow by thermodilution. Am J Cardiol 29:241–246

    Article  CAS  PubMed  Google Scholar 

  8. Batson GA, Chandrasekhar KP, Payas Y, Rickards DF (1972) Measurement of pulmonary wedge pressure by the flow directed Swan–Ganz catheter. Cardiovasc Res 6:748–752

    Article  CAS  PubMed  Google Scholar 

  9. Tamaki Y, Araie M, Kawamoto E, Eguchi S, Fujii H (1995) Non-contact, two-dimensional measurement of tissue circulation in choroid and optic nerve head using laser speckle phenomenon. Exp Eye Res 60:373–383

    Article  CAS  PubMed  Google Scholar 

  10. Isono H, Kishi S, Kimura Y, Hagiwara N, Konishi N, Fujii H (2003) Observation of choroidal circulation using index of erythrocytic velocity. Arch Ophthalmol 121:225–231

    Article  PubMed  Google Scholar 

  11. Fujii H (1994) Visualisation of retinal blood flow by laser speckle flow-graphy. Med Biol Eng Comput 32:302–304

    Article  CAS  PubMed  Google Scholar 

  12. Fujii H (2000) Laser speckle flowgraphy. In: Singh M, Radhakrishnan S, Patil KM (Eds) Medical diagnostic techniques and procedures. Narosa, New Delhi, pp 216–224

    Google Scholar 

  13. Takahashi H, Sugiyama T, Tokushige H, Maeno T, Nakazawa T, Ikeda T, Araie M (2013) Comparison of CCD-equipped laser speckle flowgraphy with hydrogen gas clearance method in the measurement of optic nerve head microcirculation in rabbits. Exp Eye Res 108:10–15

    Article  CAS  PubMed  Google Scholar 

  14. Sugiyama T, Araie M, Riva CE, Schmetterer L, Orgul S (2010) Use of laser speckle flowgraphy in ocular blood flow research. Acta Ophthalmol 88:723–729

    Article  PubMed  Google Scholar 

  15. Shiba T, Takahashi M, Hori Y, Maeno T (2012) Pulse-wave analysis of optic nerve head circulation is significantly correlated with brachial–ankle pulse-wave velocity, carotid intima–media thickness, and age. Graefes Arch Clin Exp Ophthalmol 250:1275–1281

    Article  PubMed  Google Scholar 

  16. Shiba T, Takahashi M, Hori Y, Maeno T, Shirai K (2012) Optic nerve head circulation determined by pulse wave analysis is significantly correlated with cardio ankle vascular index, left ventricular diastolic function, and age. J Atheroscler Thromb 19:999–1005

    Article  PubMed  Google Scholar 

  17. Sugiyama T (2014) Basic technology and clinical applications of the updated model of laser speckle flowgraphy to ocular diseases. Photonics 1:220–234

    Article  Google Scholar 

  18. Yanagida K, Iwase T, Yamamoto K, Ra E, Kaneko H, Murotani K, Matsui S, Terasaki H (2015) Sex-related differences in ocular blood flow of healthy subjects using laser speckle flowgraphy. Invest Ophthalmol Vis Sci 56:4880–4890

    Article  PubMed  Google Scholar 

  19. Rina M, Shiba T, Takahashi M, Hori Y, Maeno T (2015) Pulse waveform analysis of optic nerve head circulation for predicting carotid atherosclerotic changes. Graefes Arch Clin Exp Ophthalmol. doi:10.1007/s00417-015-3123-y

    PubMed  Google Scholar 

  20. Aizawa N, Yokoyama Y, Chiba N, Omodaka K, Yasuda M, Otomo T, Nakamura M, Fuse N, Nakazawa T (2011) Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma. Clin Ophthalmol 5:1171–1176

    PubMed  PubMed Central  Google Scholar 

  21. Batson GA, Chandrasekhar KP, Payas Y, Rickards DF (1972) Measurement of pulmonary wedge pressure by the flow directed Swan–Ganz catheter. Cardiovasc Res 6:748–752

    Article  CAS  PubMed  Google Scholar 

  22. Patel V, Rassam S, Newsom R, Wiek J, Kohner E (1992) Retinal blood flow in diabetic retinopathy. BMJ 305:678–683

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  23. Michelson G, Harazny J (1997) Increased vascular resistance for venous outflow in central retinal vein occlusion. Ophthalmology 104:659–663

    Article  CAS  PubMed  Google Scholar 

  24. Basturk T, Akcay M, Albayrak R, Unsal A, Ulas T, Koc Y (2012) Correlation between the resistive index values of renal and orbital arteries. Kidney Blood Press Res 35:332–329

    Article  CAS  PubMed  Google Scholar 

  25. Liu KH, Chu WC, Kong AP, Ko GT, Ma RC, Chan JW, So WY, Luk AO, Cheung KK, Ozaki R, Ahuja AT, Chan JC (2013) Intrarenal arterial resistance is associated with microvascular complications in Chinese type 2 diabetic patients. Nephrol Dial Transplant 28:651–658

    Article  CAS  PubMed  Google Scholar 

  26. Shiba T, Takahashi M, Maeno T (2014) Pulse-wave analysis of optic nerve head circulation is significantly correlated with kidney function in patients with and without chronic kidney disease. J Ophthalmol 2014, 291687

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tomoaki Shiba.

Ethics declarations

Funding

No funding was received for this research.

Conflicts of interest

The authors have no proprietary or financial interest (such as personal or professional relationships, affiliations, knowledge, or beliefs) in the subject matter or materials discussed in in any aspect of this report.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shiba, T., Takahashi, M., Hashimoto, R. et al. Pulse waveform analysis in the optic nerve head circulation reflects systemic vascular resistance obtained via a Swan–Ganz catheter. Graefes Arch Clin Exp Ophthalmol 254, 1195–1200 (2016). https://doi.org/10.1007/s00417-016-3289-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00417-016-3289-y

Keywords

Navigation