Abstract
Purpose
To assess a new non-contact anterior optical coherence tomography (OCT) system for anterior chamber evaluation.
Methods
A new commercial 131-nm infrared light anterior OCT system was used for anterior chamber evaluation. Forty-four eyes of 35 subjects (18 normal subjects, 17 subjects with anterior chamber abnormalities) were enrolled in the study.
Results
Eyes were divided into those with narrowed, broadened and normal anterior chamber depth. Anterior chamber angle dynamics were assessed in three patients with angle-closure glaucoma and cataract extraction. Anterior OCT was also used for visualization of the anterior chamber (OCT goniometry) in a subject with multiple local anaesthetic allergies with phobia regarding conventional contact gonioscopy.
Conclusions
Anterior OCT is a new, easy-to-handle, non-contact technique that allows exact evaluation of anterior chamber parameters such as anterior chamber depth, chamber angle dynamics, corneal curvature and corneal thickness.
Similar content being viewed by others
References
Baikoff G, Lutun E, Ferraz C, Wei J (2004) Static and dynamic analysis of the anterior segment with optical coherence tomography. J Cataract Refract Surg 30:1843–1850
Baikoff G, Jitsuo Jodai H, Bourgeon G (2005) Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer. J Cataract Refract Surg 31:1722–1728
Goldsmith JA, Li Y, Chalita MR, Westphal V, Patil CA, Rollins AM, Izatt JA, Huang D (2005) Anterior chamber width measurement by high-speed optical coherence tomography. Ophthalmology 112:238–244
Karandish A, Wirbelauer C, Haeberle H, Pham DT (2004) Reproducibility of goniometry with slit-lamp adapted optical coherence tomography. Ophthalmologe 101:608–613
Leung CK, Chan WM, Ko CY, Chui SI, Woo J, Tsang MK, Tse RK (2005) Visualization of anterior chamber angle dynamics using optical coherence tomography. Ophthalmology 112:980–984
Radhakrishnan S, Goldsmith J, Huang D, Westphal V, Dueker DK, Rollins AM, Izatt JA, Smith SD (2005) Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles. Arch Ophthalmol 123:1053–1059
Wirbelauer C, Karandish A, Haberle H, Pham DT (2005) Noncontact goniometry with optical coherence tomography. Arch Ophthalmol 123:179–185
Wirbelauer C, Gochmann R, Pham DT (2005) Imaging of the anterior eye chamber with optical coherence tomography. Klin Monatsbl Augenheilkd 222:856–862
Author information
Authors and Affiliations
Corresponding author
Additional information
None of the authors has any financial or proprietary interest in any product or material mentioned in the text.
Rights and permissions
About this article
Cite this article
Dawczynski, J., Koenigsdoerffer, E., Augsten, R. et al. Anterior optical coherence tomography: a non-contact technique for anterior chamber evaluation. Graefe's Arch Clin Exp Ophthalmol 245, 423–425 (2007). https://doi.org/10.1007/s00417-006-0383-6
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00417-006-0383-6