Skip to main content
Account

Table 5 Robustness of MiRNA isolated using the Bioneer AccuPrep® genomic DNA extraction kit, Qiagen QIAamp DNA mini kit, and Qiagen MiRNeasy Tissue/Cells advanced micro kit from human saliva samples of 400 µL, 200 µL, 100 µL, 50 µL, and 25 µL

From: Evaluation of extraction methods for co-isolation of nucleic acid from human saliva for forensic body fluid identification

 

Robustness of miRNA Yield

Extraction

Method

Sample

Volume (µL)

CV%

Acceptance

P-value

Genomic DNA Kit

400

4.91%

CV < 5%

< 0.0001

200

1.71%

CV < 5%

100

14.78%

CV < 20%

50

7.53%

CV < 10%

25

23.45%

CV < 30%

QIAamp DNA Kit

400

5.53%

CV < 10%

0.21

200

11.68%

CV < 20%

100

2.99%

CV < 5%

50

54.84%

CV > 30%

25

11.26%

CV < 20%

miRNeasy Tissue Kit

400

8.82%

CV < 10%

< 0.001

200

22.22%

CV < 30%

100

9.85%

CV < 10%

50

2.84%

CV < 5%

25

19.73%

CV < 20%

  1. CV% Coefficient of Variation, µL Microliters, Mean Average P-value Probability value