Abstract
The estimation of the time since death is an important task in forensic medicine that mainly relies on body cooling in the early post-mortem period. The rectum has been traditionally used to determine the central core temperature after death, though the external auditory canal has been proposed as an alternative site by several authors. The objective of this study was to assess the ability of four body temperature-based methods (Henssge’s rectal nomogram, Henssge’s brain nomogram, and Baccino’s both interval and global formulae based on ear temperature) to estimate the post-mortem interval (PMI). PMI calculations were carried out based on ear and rectal temperature measurements performed with a reference metal probe on 100 inpatient bodies with an average PMI of 4.5 ± 2.5 h. For practical purposes, ear temperature measurements were applied to Henssge’s brain nomogram. All methods could be applied to 81 cases, since high body temperatures prevented the rectal nomogram method from being used in most of the remaining cases. The actual PMI was within the time interval (95% CI) provided by the rectal nomogram method in 72.8% of cases, and in 63.0% to 76.5% of cases when using ear temperature-based methods. The proportions of adequate estimates did not differ statistically between the different methods. When the methods failed to provide a reliable time interval, all except the brain nomogram tended to underestimate the PMI. Similar results were obtained in the subgroup of normothermic patients at the time of death (n = 63), confirming that the PMI calculations had not been biased by the inclusion of patients with thermoregulation disorders. Our findings are in accordance with the published literature which suggests that ear temperature-based methods are as reliable as those based on rectal temperature for estimating the early PMI and that they may be used as quick, simple, and non-invasive methods at the scene, although caution should be taken in interpreting their results given their high error rates. However, further research including field studies is recommended to confirm their practical relevance in forensic casework.
Similar content being viewed by others
References
Madea B (2016) Methods for determining time of death. Forensic Sci Med Pathol 12:451–485. https://doi.org/10.1007/s12024-016-9776-y
Henssge C (1988) Death time estimation in case work. I. The rectal temperature time of death nomogram. Forensic Sci Int 38:209–236
Henssge C, Althaus L, Bolt J et al (2000) Experiences with a compound method for estimating the time since death. I. Rectal temperature nomogram for time since death. Int J Legal Med 113:303–319
Henssge C, Beckmann ER, Wischhusen F, Brinkmann B (1984) Determination of the time of death by measurement of central brain temperature. Z Rechtsmed 93:1–22
Henssge C, Frekers R, Reinhardt BER (1984) Determination of the time of death based on simultaneous measurement of brain and rectal temperatures. Z Rechtsmed 93:123–133. https://doi.org/10.1007/BF00200771
Benzinger T, Taylor G (1963) Cranial measurements of internal temperature in man. In: Herzfeld CM (ed) Temperature Its Measurement and Control in Science and Industry. Volume 3, Part 3: Biology and Medicine. Reinhold Publishing Corporation, New York
Rutty GN (2005) The estimation of the time since death using temperatures recorded from the external auditory canal : Part I: Can a temperature be recorded and interpreted from this site? Forensic Sci Med Pathol 1:41–51. https://doi.org/10.1385/FSMP:1:1:041
Baccino E, Martin LDS, Schuliar Y et al (1996) Outer ear temperature and time of death. Forensic Sci Int 83:133–146. https://doi.org/10.1016/S0379-0738(96)02027-0
Baccino E, Cattaneo C, Jouineau C et al (2007) Cooling rates of the ear and brain in pig heads submerged in water: implications for postmortem interval estimation of cadavers found in still water. Am J Forensic Med Pathol 28:80–85. https://doi.org/10.1097/01.paf.0000233529.50779.08
Rutty G, Smith N, Rutty J (1996) The use of infrared ear thermometry for determination of time since death in the early post mortem period. J Pathol 179(Suppl):13A
Baccino E (1997) Response to Dr. Rutty’s letter re: ‘Outer ear temperature and time of death. Forensic Sci Int 87:173
Wunderlich C, Seguin E (1871) Medical thermometry, and human temperature. William Wood & Company, New York
Mackowiak PA (1997) History of clinical thermometry. In: Fever: basic mechanisms and management. Lippincott-Raven Publishers, Philadelphia
Nokes LD, Flint T, Jaafar S, Knight BH (1992) The use of either the nose or outer ear as a means of determining the postmortem period of a human corpse. Forensic Sci Int 54:153–158. https://doi.org/10.1016/0379-0738(92)90159-t
Myers MJ, Henderson M (1996) Assessment of two devices for measuring tympanic membrane temperature in swine, dairy cattle, and dairy calves. J Am Vet Med Assoc 208:1700–1701
Proctor KW, Kelch WJ, New JC (2009) Estimating the time of death in domestic canines. J Forensic Sci 54:1433–1437. https://doi.org/10.1111/j.1556-4029.2009.01156.x
Nokes LD, Hicks B, Knight BH (1985) The post-mortem temperature plateau–fact or fiction? Med Sci Law 25:263–264. https://doi.org/10.1177/002580248502500406
Rutty GN (2015) The use of temperatures recorded from the external auditory canal for the estimation of the post-mortem interval. In: Madea B (ed) Estimation of the time since death, 3rd edn. CRC Press, London, pp 134–151
Rutty GN (2001) The use of temperatures recorded from the external auditory canal in the estimation of the time since death. Medical Doctorate Thesis, University of Sheffield, England
Rutty GN (2005) The estimation of the time since death using temperatures recorded from the external auditory canal : Part II: Using single temperatures from this site to estimate the time since death with consideration of environmental or body “factors” that could affect the estimation. Forensic Sci Med Pathol 1:113–123. https://doi.org/10.1385/FSMP:1:2:113
Kanawaku Y, Kanetake J, Komiya A et al (2007) Computer simulation for postmortem cooling processes in the outer ear. Leg Med (Tokyo) 9:55–62. https://doi.org/10.1016/j.legalmed.2006.09.006
Peyron P-A, Hirtz C, Baccino E et al (2021) Tau protein in cerebrospinal fluid: a novel biomarker of the time of death? Int J Legal Med. https://doi.org/10.1007/s00414-021-02558-3
Rutty GN (1997) Concerning the paper by Baccino et al., entitled: “Outer ear temperature and time of death” (Forensic Sci. Int., 83 (1996) 133–146). Forensic Sci Int 87:171–173
Cattaneo C, Di Giancamillo A, Campari O et al (2009) Infrared tympanic thermography as a substitute for a probe in the evaluation of ear temperature for post-mortem interval determination: a pilot study. J Forensic Leg Med 16:215–217. https://doi.org/10.1016/j.jflm.2008.07.005
Meusy A, Peyron P-A, Molinari N et al (2017) Étude préliminaire de l’exactitude et du biais systématique de deux thermomètres infrarouges pour l’estimation du délai post-mortem précoce : peut-on utiliser les thermomètres infrarouges commercialisés pour déterminer l’heure du décès ? Rev Médecine Légale 8:97–104. https://doi.org/10.1016/j.medleg.2017.04.002
Franchi A, Clerc-Urmès I, Martrille L (2020) Estimating the time of death with infrared tympanic thermometer: a new prospective study in France. Int J Legal Med 134:591–595. https://doi.org/10.1007/s00414-019-02078-1
Laplace K, Baccino E, Peyron P-A (2021) Is infrared thermometry suitable for the determination of the time since death based on ear temperature? A comparative study of two measurement methods. Int J Legal Med. https://doi.org/10.1007/s00414-021-02579-y
Zawadzka M, Szmuda M, Mazurkiewicz-Bełdzińska M (2017) Thermoregulation disorders of central origin - how to diagnose and treat. Anaesthesiol Intensive Ther 49:227–234. https://doi.org/10.5603/AIT.2017.0042
Roush MK, Nelson KM (1993) Understanding drug-induced febrile reactions. Am Pharm NS33:39–42. https://doi.org/10.1016/s0160-3450(15)30635-8
Protsiv M, Ley C, Lankester J et al (2020) Decreasing human body temperature in the United States since the industrial revolution. Elife 9:e49555. https://doi.org/10.7554/eLife.49555
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethics approval
This article does not contain any studies with live human participants or animals performed by any of the authors. Ethical approval was obtained from the Institutional Review Board of the University Hospital of Montpellier, Nr. 2019_IRB-MTP_11-08.
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Laplace, K., Baccino, E. & Peyron, PA. Estimation of the time since death based on body cooling: a comparative study of four temperature-based methods . Int J Legal Med 135, 2479–2487 (2021). https://doi.org/10.1007/s00414-021-02635-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00414-021-02635-7