Abstract
Currently, the amplification step of most forensic DNA profiling systems takes 3–4 h to complete. A decrease in the amplification time would allow for increased laboratory throughput, which may help reduce backlog when is due to limited cycling capacity. By using the SpeedSTAR™ HS Polymerase (Takara Bio, Otsu, Japan) in combination with the Veriti® (Applied Biosystems, Foster City, CA, USA) rapid thermal cycler, the amplification time for the PowerPlex® 16 HS (Promega, Madison, WI, USA) kit was reduced by 66 % (1 h). The sensitivity of this fast method was comparable to the standard system (0.13 ng). Although this rapid protocol showed an increase in average stutter ratios (2.8 %) and a decrease in average peak height ratios (7 %) across all loci when compared with standard conditions, it was able to consistently generate reliable DNA profiles. The results of this study indicate that the rapid protocol could be implemented in forensic laboratories with an optimal range of 0.25–2 ng of input DNA using appropriate analytical interpretation guidelines.
References
Aboud M, Oh HH, McCord B (2013) Rapid direct PCR for forensic genotyping in under 25 min. Electrophoresis 34:1539–1547
Verheij S, Harteveld J, Sijen T (2012) A protocol for direct and rapid multiplex PCR amplification on forensically relevant samples. Forensic Sci Int Genet 6:167–175
Vallone PM, Hill CR, Butler JM (2008) Demonstration of rapid multiplex PCR amplification involving 16 genetic loci. Forensic Sci Int Genet 3:42–45
Wang DY, Chang CW, Hennessy LK (2009) Rapid STR analysis of single source DNA samples in 2 h. Forensic Sci Int Genet Suppl Ser 2:115–116
GlobalFiler™ PCR Amplification Kit User Guide, version dated 8/2013. Life Technologies™, Carlsbad, CA
Flores S, Sun J, King J, Budowle B (2014) Internal validation of the GlobalFiler™ Express PCR Amplification Kit for the direct amplification of reference DNA samples on a high-throughput automated workflow. Forensic Sci Int Genet 10:33–39
PowerPlex® Fusion System E Brochure, version dated 9/2012. Promega, Madison, WI
Oostdik K, French J, Yet D, Smalling B, Nolde C, Vallone PM et al (2013) Developmental validation of the PowerPlex® 18D System, a rapid STR multiplex for analysis of reference samples. Forensic Sci Int Genet 7:129–135
Quality Assurance Standards for Forensic DNA Testing Laboratories. Federal Bureau of Investigation. http://www.fbi.gov/about-us/lab/biometric-analysis/codis/qas_testlabs. Accessed 11 March 2014
Ballantyne J, Hanson E, Green R, Holt A, Mulero J (2013) Enhancing the sexual assault workflow: testing of next generation DNA assessment and Y-STR systems. Forensic Sci Int Genet Suppl Ser 4:e228–e229
Turrina S, Caratti S, De Leo D (2013) Evaluation of PowerPlex® Fusion System on samples from forensic casework. Forensic Sci Int Genet Suppl Ser 4:e210–e211
Giese H, Lam R, Selden R, Tan E (2009) Fast multiplexed polymerase chain reaction for conventional and microfluidic short tandem repeat analysis. J Forensic Sci 54:1287–1296
Foster A, Laurin N (2012) Development of a fast PCR protocol enabling rapid generation of AmpFlSTR® Identifiler® profiles for genotyping of human DNA. Investig Genet. doi:10.1186/2041-2223-3-6
Laurin N, Frégeau C (2012) Optimization and validation of a fast amplification protocol for AmpFℓSTR® Profiler Plus® for rapid forensic human identification. Forensic Sci Int Genet 6:47–57
Bahlmann S, Hughes-Stamm S, Gangitano D (2014) Development and evaluation of a rapid PCR method for the PowerPlex®S5 system for forensic DNA profiling. Leg Med (Tokyo) 16(4):227–233
Krenke BE, Tereba A, Anderson SJ, Buel E, Culhane S, Finis CJ et al (2002) Validation of a 16-locus fluorescent multiplex system. J Forensic Sci 47(4):773–785
Validation Guidelines for DNA Analysis Methods. Scientific Working Group on DNA Analysis Methods. http://swgdam.org/SWGDAM_Validation_Guidelines_APPROVED_Dec_2012.pdf. Accessed 4 March 2014
Budowle B, Smith J, Moretti T, DiZinno J (2000) DNA typing protocols: molecular biology and forensic analysis. Eaton Publishing Company, Natick
Walsh PS, Metzger DA, Higuchi R (1991) Chelex 100 as a medium for simple extraction of DNA for PCR-based typing from forensic material. Biotechniques 10(4):506–513
PowerPlex® 16 HS System Technical Manual, version dated 6/2012. Promega, Madison, WI
Internal Validation Guide of Autosomal STR Systems for Forensic Laboratories. Reference manual. Revised 9/13 (Promega). http://www.promega.com/resources/pubhub/applications-notes/ge053-validation-of-str-systems-reference-manual/. Accessed 24 May 2014.
QIAamp® DNA Investigator Handbook, version dated 6/2012. QIAGEN®, Hilden, Germany
Ensenberger MG, Thompson J, Hill B, Homick K, Kearney V, Mayntz-Press KA et al (2010) Developmental validation of the PowerPlex® 16 HS System: an improved 16-locus fluorescent STR multiplex. Forensic Sci Int Genet 4:257–264
AmpFlSTR® Profiler Plus® PCR Amplification Kit User’s Manual, version dated 03/2012, Applied Biosystems, Carlsbad, CA
Butler JM (2005) Forensic DNA, typing, 2nd edn. Elsevier Academic Press, Burlington
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
White, J., Hughes-Stamm, S. & Gangitano, D. Development and validation of a rapid PCR method for the PowerPlex® 16 HS system for forensic DNA identification. Int J Legal Med 129, 715–723 (2015). https://doi.org/10.1007/s00414-014-1102-1
Received:
Accepted:
Published:
Issue Date: