Abstract
A significant source of information on radiation-induced biological effects following in-utero irradiation stems from studies of atomic bomb survivors who were pregnant at the time of exposure in Hiroshima, and to a lesser extent, from survivors in Nagasaki. Dose estimates to the developing fetus for these survivors have been assigned in prior dosimetry systems of the Radiation Effects Research Foundation as the dose to the uterine wall within the non-pregnant adult stylized phantom, originally designed for the dosimetry system DS86 and then carried forward in DS02. In a prior study, a new J45 (Japanese 1945) series of high-resolution phantoms of the adult pregnant female at 8 weeks, 15 weeks, 25 weeks, and 38-weeks post-conception was presented. Fetal and maternal organ doses were estimated by computationally exposing the pregnant female phantom series to DS02 free-in-air cumulative photon and neutron fluences at three distances from the hypocenter at both Hiroshima and Nagasaki under idealized frontal (AP) and isotropic (ISO) particle incidence. In this present study, this work was extended using realistic angular fluences (480 directions) from the DS02 system for seven radiation source terms, nine different radiation dose components, and five shielding conditions. In addition, to explore the effects of fetal position within the womb, four new phantoms were created and the same irradiation scenarios were performed. General findings are that the current DS02 fetal dose surrogate overestimates values of fetal organ dose seen in the J45 phantoms towards the cranial end of the fetus, especially in the later stages of pregnancy. For example, for in-open exposures at 1000 m in Hiroshima, the ratio of J45 fetal brain dose to DS02 uterine wall dose is 0.90, 0.82, and 0.70 at 15 weeks, 25 weeks, and 38-weeks, respectively, for total gamma exposures, and are 0.64, 0.44, and 0.37 at these same gestational ages for total neutron exposures. For organs in the abdominal and pelvic regions of the fetus, dose gradients across gestational age flatten and later reverse, so that DS02 fetal dosimetry begins to underestimate values of fetal organ dose as seen in the J45 phantoms. For example, for the same exposure scenario, the ratios of J45 fetal kidney dose to DS02 uterine wall dose are about 1.09 from 15 to 38 weeks for total gamma dose, and are 1.30, 1.56, and 1.75 at 15 weeks, 25 weeks, and 38 weeks, respectively, for the total neutron dose. Results using the new fetal positioning phantoms show this trend reversing for a head-up, breach fetal position. This work supports previous findings that the J45 pregnant female phantom series offers significant opportunities for gestational age-dependent assessment of fetal organ dose without the need to invoke the uterine wall as a fetal organ surrogate.
Similar content being viewed by others
Data availability
All simulation results are fully available to the reader in the series of electronic annexes.
Notes
We note that with increasing distance from the bomb hypocenter, gamma and neutron radiation energy spectra tend to harden with concomitant increases in their mean energy.
References
Bahadori AA, Johnson P, Jokisch DW, Eckerman KF, Bolch WE (2011) Response functions for computing absorbed dose to skeletal tissues from neutron irradiation. Phys Med Biol 56(21):6873–6897
BEIR (2005) Health risks from exposure to low levels of ionizing radiation: BEIR VII—phase 2. National Research Council, Washington, DC
Cunningham FG, Leveno KJ, Bloom SL, Dashe JS, Hoffman BL, Casey BM, Spong CY (2018) Williams obstetrics, 25th edn. McGraw-Hill, New York, NY
Griffin K, Paulbeck C, Bolch WE, Cullings HM, Egbert SD, Funamoto S, Sato T, Endo A, Hertel N, Lee C (2019) Dosimetric impact of a new computational voxel phantom series for the Japanese atomic bomb survivors: children and adults. Radiat Res 191:369–379
Griffin KT, Sato T, Funamoto S, Chizhov K, Domal S, Paulbeck C, Bolch W, Cullings HM, Egbert S, Endo A, Hertel N, Lee C (2022) Japanese pediatric and adult atomic bomb survivor dosimetry: potential improvements using the J45 phantom series and modern Monte Carlo transport. Radiat Environ Biophys 61:73–86
Hirayama H, Namito Y, Bielajew AF, Wilderman SJ, Nelson WR (2005) Technical report SLAC-R-730 and KEK report 2005–8: the EGS5 code system. Stanford Linear Accelerator Center, Stanford, CA
ICRP (2007) ICRP publication 103: recommendations of the international commission on radiological protection. Ann ICRP 37(2–4):1–332
Johnson PB, Bahadori AA, Eckerman KF, Lee C, Bolch WE (2011) Response functions for computing absorbed dose to skeletal tissues from photon irradiation - an update. Phys Med Biol 56(8):2347–2365
Kerr GD (2012) DS86 and DS02 organ dose calculations. Radiat Prot Dosimetry 149(1):15–20
Maynard MR, Geyer JW, Aris JP, Shifrin RY, Bolch W (2011) The UF family of hybrid phantoms of the developing human fetus for computational radiation dosimetry. Phys Med Biol 56(15):4839–4879
Maynard MR, Long NS, Moawad NS, Shifrin RY, Geyer AM, Fong G, Bolch WE (2014) The UF Family of hybrid phantoms of the pregnant female for computational radiation dosimetry. Phys Med Biol 59(15):4325–4343
Otake M, Schull WJ (1993) Radiation-related small head sizes among prenatally exposed A-bomb survivors. Int J Radiat Biol 63(2):255–270
Paulbeck C, Griffin K, Lee C, Cullings HM, Egbert SD, Funamoto S, Sato T, Endo A, Hertel N, Bolch WE (2019) Dosimetric impact of a new computational voxel phantom series for the Japanese atomic bomb survivors: pregnant females. Radiat Res 192:538–561
Preston DL, Cullings H, Suyama A, Funamoto S, Nishi N, Soda M, Mabuchi K, Kodama K, Kasagi F, Shore RE (2008) Solid cancer incidence in atomic bomb survivors exposed in utero or as young children. J Natl Cancer Inst 100(6):428–436
RERF (2005) Reassessment of the atomic bomb radiation dosimetry for hiroshima and nagasaki—dosimetry system 2002. Radiation Effects Research Foundation, Hiroshima, Japan
RERF (1987) US-Japan Joint Assessment of Atomic Bomb Radiation Dosimetry in Hiroshima and Nagasaki - Final Report. Radiation Effects Research Foundation, Hiroshima, Japan.
Sato T, Iwamoto Y, Hashimoto S, Ogawa H, Furuta T, Abe S, Kai T, Tasi P, Matsuda N, Iwase H, Shigyo N, Sihver L, Nitta K (2018) Features of particle and heavy ion transport code system (PHITS) version 3.02. J Nucl Sci Tech 55(6):684–690
Sato T, Funamoto S, Paulbeck C, Griffin K, Lee C, Cullings H, Egbert SD, Endo A, Hertel N, Bolch WE (2020) Dosimetric impact of a new computational voxel phantom series for the japanese atomic bomb survivors: methodological improvements and organ dose response functions. Radiat Res 194(4):390–402
Shibata K, Iwamoto O, Nakagawa T, Iwamoto N, Ichihara A, Kunieda S (2011) JENDL-4.0: a new library for nuclear science and engineering. J Nucl Sci Tech 48:1–30
Acknowledgements
This work was supported by Radiation Effects Research Foundation, National Institutes of Health, Japan Atomic Energy Agency.
Funding
The Radiation Effects Research Foundation of Hiroshima and Nagasaki, Japan, is a public interest foundation funded by the Japanese Ministry of Health, Labor, and Welfare and the US Department of Energy. The views of the authors do not necessarily reflect those of the two governments. This publication was supported by RERF Research Protocol 18–59.
Author information
Authors and Affiliations
Contributions
Study design (CJP, TS, SF, CL, KTG, HMC, SDE, WEB), phantom modeling and MC simulations (CJP, WEB), data presentation (CJP, WEB), data analyses and interpretation (all authors), manuscript editing and final review (all authors).
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Paulbeck, C.J., Sato, T., Funamoto, S. et al. Fetal atomic bomb survivor dosimetry using the J45 series of pregnant female phantoms with realistic survivor exposure scenarios: comparisons to dose estimates in the DS02 system. Radiat Environ Biophys 62, 317–329 (2023). https://doi.org/10.1007/s00411-023-01032-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00411-023-01032-5