End-to-end test of respiratory gating radiation therapy for lung stereotactic body radiation therapy treatments

  • Original Article
  • Published:
Radiation and Environmental Biophysics Aims and scope Submit manuscript

Abstract

In this paper, a dosimetric end-to-end test of respiratory gated radiation therapy (RGRT) applied in lung cancer stereotactic body radiation therapy (SBRT) was performed. The test was performed from treatment simulation to treatment delivery using a QUASAR phantom, for regular, slightly irregular and irregular breathing patterns in phase- and amplitude-gated modes. A mechanical and dosimetric verification was performed to evaluate all steps of the proposed treatment workflow. Dose measurements were performed using a PinPoint ion chamber and GafChromic EBT3 films. Mechanical verification confirmed good function of the chosen systems. Dosimetric verification showed good agreement between planned and measured doses, for the phase-gated versus amplitude-gated modes: 1.4 ± 0.4% versus 1.2 ± 0.2% for regular, 2.8 ± 0.3% versus 3.0 ± 0.3% for slightly irregular, and 6.2 ± 0.7% versus 7.4 ± 0.5% for irregular breathing patterns. The gamma passing rates for 3%/3 mm and 2%/2 mm criteria, comparing phase- versus amplitude-gated modes, were 99.0 ± 0.3% versus 99.5 ± 0.2% and 95.2 ± 0.2% versus 96.1 ± 0.2% for the regular, 97.4 ± 0.8% versus 98.0 ± 0.6% and 91.7 ± 0.5% versus 92.4 ± 0.4% for the slightly irregular, and 96.4 ± 0.5% versus 95.3 ± 0.7% and 86.4 ± 0.5% versus 84.6 ± 0.7% for the irregular breathing patterns, respectively. It is concluded that using equipment and workflow for the treatment of lung cancer by means of SBRT in RGRT mode is safe and efficient, for regular and slightly irregular breathing patterns.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

Download references

Acknowledgements

Nothing to declare.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Milovan Savanović.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Savanović, M., Štrbac, B., Jaroš, D. et al. End-to-end test of respiratory gating radiation therapy for lung stereotactic body radiation therapy treatments. Radiat Environ Biophys 61, 651–660 (2022). https://doi.org/10.1007/s00411-022-00990-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00411-022-00990-6

Keywords

Navigation