In this paper, a dosimetric end-to-end test of respiratory gated radiation therapy (RGRT) applied in lung cancer stereotactic body radiation therapy (SBRT) was performed. The test was performed from treatment simulation to treatment delivery using a QUASAR phantom, for regular, slightly irregular and irregular breathing patterns in phase- and amplitude-gated modes. A mechanical and dosimetric verification was performed to evaluate all steps of the proposed treatment workflow. Dose measurements were performed using a PinPoint ion chamber and GafChromic EBT3 films. Mechanical verification confirmed good function of the chosen systems. Dosimetric verification showed good agreement between planned and measured doses, for the phase-gated versus amplitude-gated modes: 1.4 ± 0.4% versus 1.2 ± 0.2% for regular, 2.8 ± 0.3% versus 3.0 ± 0.3% for slightly irregular, and 6.2 ± 0.7% versus 7.4 ± 0.5% for irregular breathing patterns. The gamma passing rates for 3%/3 mm and 2%/2 mm criteria, comparing phase- versus amplitude-gated modes, were 99.0 ± 0.3% versus 99.5 ± 0.2% and 95.2 ± 0.2% versus 96.1 ± 0.2% for the regular, 97.4 ± 0.8% versus 98.0 ± 0.6% and 91.7 ± 0.5% versus 92.4 ± 0.4% for the slightly irregular, and 96.4 ± 0.5% versus 95.3 ± 0.7% and 86.4 ± 0.5% versus 84.6 ± 0.7% for the irregular breathing patterns, respectively. It is concluded that using equipment and workflow for the treatment of lung cancer by means of SBRT in RGRT mode is safe and efficient, for regular and slightly irregular breathing patterns.
Similar content being viewed by others
References
Ahnesjö A (1989) Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. Med Phys 16:577–592. https://doi.org/10.1118/1.596360
Aznar MC, Warren S, Hoogeman M, Josipovic M (2018) The impact of technology on the changing practice of lung SBRT. Phys Med 47:129–138. https://doi.org/10.1016/j.ejmp.2017.12.020
Benedict SH, Yenice KM, Followill D, Galvin JM, Hinson W, Kavanagh B, Keall P, Lovelock M, Meeks S, Papiez L, Purdie T, Sadagopan R, Schell MC, Salter B, Schlesinger DJ, Shiu AS, Solberg T, Song DY, Stieber V, Timmerman R, Tomé WA, Verellen D, Wang L, Yin F-F (2010) Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med Phys 37:4078–4101. https://doi.org/10.1118/1.3438081
Blomgren H, Lax I, Näslund I, Svanström R (1995) Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator. Clinical experience of the first thirty-one patients. Acta Oncol 34:861–870. https://doi.org/10.3109/02841869509127197
Chung H, Jung J, Jeong C, Kwak J, Park J-H, Kim SS, Yoon SM, Song SY, Kim JH, Choi EK, Cho S, Cho B (2018) Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy. PLoS ONE 13:e0202765. https://doi.org/10.1371/journal.pone.0202765
Followill DS, Evans DR, Cherry C, Molineu A, Fisher G, Hanson WF, Ibbott GS (2007) Design, development, and implementation of the radiological physics center’s pelvis and thorax anthropomorphic quality assurance phantoms. Med Phys 34:2070–2076. https://doi.org/10.1118/1.2737158
Jiang SB (2006) Technical aspects of image-guided respiration-gated radiation therapy. Med Dosim 31:141–151. https://doi.org/10.1016/j.meddos.2005.12.005
Josipovic M, Persson GF, Logadottir A, Smulders B, Westmann G, Bangsgaard JP (2012) Translational and rotational intra- and inter-fractional errors in patient and target position during a short course of frameless stereotactic body radiotherapy. Acta Oncol 51:610–617. https://doi.org/10.3109/0284186X.2011.626448
Kadoya N, Nakajima Y, Saito M, Miyabe Y, Kurooka M, Kito S, Fujita Y, Sasaki M, Arai K, Tani K, Yagi M, Wakita A, Tohyama N, Jingu K (2016) Multi-institutional validation study of commercially available deformable image registration software for thoracic images. Int J Radiat Oncol Biol Phys 96:422–431. https://doi.org/10.1016/j.ijrobp.2016.05.012
Keall P, Vedam S, George R, Bartee C, Siebers J, Lerma F, Weiss E, Chung T (2006a) The clinical implementation of respiratory-gated intensity-modulated radiotherapy. Med Dosim 31:152–162. https://doi.org/10.1016/j.meddos.2005.12.002
Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR, Ramsey CR, Van Herk MB, Vedam SS, Wong JW, Yorke E (2006b) The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 33:3874–3900. https://doi.org/10.1118/1.2349696
Klein EE, Hanley J, Bayouth J, Yin F-F, Simon W, Dresser S, Serago C, Aguirre F, Ma L, Arjomandy B, Liu C, Sandin C, Holmes T, Task Group 142, American Association of Physicists in Medicine (2009) Task Group 142 report: quality assurance of medical accelerators. Med Phys 36:4197–4212. https://doi.org/10.1118/1.3190392
Maselesele HV, Msimang ZN, Maphumulo N, van der Merwe D (2019) South African pilot study: end-to-end radiotherapy and medical physics dosimetry audits. South Afr J Oncol 3:8. https://doi.org/10.4102/sajo.v3i0.81
Pepin EW, Wu H, Shirato H (2011) Dynamic gating window for compensation of baseline shift in respiratory-gated radiation therapy. Med Phys 38:1912–1918. https://doi.org/10.1118/1.3556588
PinPoint Ion Chamber 31015—PTW Freiburg GmbH [WWW Document], n.d. available at https://www.ptwdosimetry.com/en/products/pinpoint-ion-chamber-31015/ (accessed 1.21.22).
Purdie TG, Bissonnette J-P, Franks K, Bezjak A, Payne D, Sie F, Sharpe MB, Jaffray DA (2007) Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys 68:243–252. https://doi.org/10.1016/j.ijrobp.2006.12.022
Qian J, Xing L, Liu W, Luxton G (2011) Dose verification for respiratory-gated volumetric modulated arc therapy. Phys Med Biol 56:4827–4838. https://doi.org/10.1088/0031-9155/56/15/013
Ramsey CR, Scaperoth D, Arwood D, Oliver AL (1999) Clinical efficacy of respiratory gated conformal radiation therapy. Med Dosim 24:115–119. https://doi.org/10.1016/s0958-3947(99)00006-0
Report 24 (1976) Journal of the International Commission on Radiation Units and Measurements os13, NP-NP, doi: https://doi.org/10.1093/jicru/os13.1.Report24
Savanovic M, Strbac B, Jaros D, Cazic D, Kolarevic G, Foulquier J-N (2020a) Assessment of internal and external surrogates for lung stereotactic body radiation therapy. Iran J Med Phys. https://doi.org/10.22038/ijmp.2020.50131.1820
Savanovic M, Strbac B, Jaros D, Foulquier J-N (2020b) The assessment of consecutive 4D-CT scans during simulation for lung stereotactic body radiation therapy patients. Pol J Med Phys Eng 26:193–199. https://doi.org/10.2478/pjmpe-2020-0023
Shi C, Tang X, Chan M (2017) Evaluation of the new respiratory gating system. Precis Radiat Oncol 4:127–133. https://doi.org/10.1002/pro6.34
Sonke J-J, Rossi M, Wolthaus J, van Herk M, Damen E, Belderbos J (2009) Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance. Int J Radiat Oncol Biol Phys 74:567–574. https://doi.org/10.1016/j.ijrobp.2008.08.004
van de Sörnsen Koste JR, Cuijpers JP, de Geest FG, Lagerwaard FJ, Slotman BJ, Senan S (2007) Verifying 4D gated radiotherapy using time-integrated electronic portal imaging: a phantom and clinical study. Radiat Oncol 2:32. https://doi.org/10.1186/1748-717X-2-32
van der Geld YG, Lagerwaard FJ, van de Sörnsen Koste JR, Cuijpers JP, Slotman BJ, Senan S (2006) Reproducibility of target volumes generated using uncoached 4-dimensional CT scans for peripheral lung cancer. Radiat Oncol 1:43. https://doi.org/10.1186/1748-717X-1-43
Vedam SS, Keall PJ, Kini VR, Mohan R (2001) Determining parameters for respiration-gated radiotherapy. Med Phys 28:2139–2146. https://doi.org/10.1118/1.1406524
Wesolowska P, Georg D, Lechner W, Kazantsev P, Bokulic T, Tedgren AC, Adolfsson E, Campos AM, Alves VGL, Suming L, Hao W, Ekendahl D, Koniarova I, Bulski W, Chelminski K, Samper JLA, Vinatha SP, Rakshit S, Siri S, Tomsejm M, Tenhunen M, Povall J, Kry SF, Followill DS, Thwaites DI, Izewska J (2019) Testing the methodology for a dosimetric end-to-end audit of IMRT/VMAT: results of IAEA multicentre and national studies. Acta Oncol 58:1731–1739. https://doi.org/10.1080/0284186X.2019.1648859
Woods K, Rong Y (2015) Technical Report: TG-142 compliant and comprehensive quality assurance tests for respiratory gating. Med Phys 42:6488–6497. https://doi.org/10.1118/1.4932363
Yoganathan SA, Maria Das KJ, Agarwal A, Kumar S (2013) Performance evaluation of respiratory motion-synchronized dynamic IMRT delivery. J Appl Clin Med Phys 14:4103. https://doi.org/10.1120/jacmp.v14i3.4103
Acknowledgements
Nothing to declare.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Savanović, M., Štrbac, B., Jaroš, D. et al. End-to-end test of respiratory gating radiation therapy for lung stereotactic body radiation therapy treatments. Radiat Environ Biophys 61, 651–660 (2022). https://doi.org/10.1007/s00411-022-00990-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00411-022-00990-6