Skip to main content
Log in

A Monte Carlo study to investigate the feasibility to use the Moroccan panoramic irradiator in sterile insect technique programs

  • Original Article
  • Published:
Radiation and Environmental Biophysics Aims and scope Submit manuscript

Abstract

Mediterranean fly pest (Ceratitis) is one of the most destructive pests of fruit species in Morocco. The sterile insect technique (SIT) is an environmentally friendly strategy that uses ionizing radiation to sterilize adult insects. Morocco has a panoramic gamma irradiator used to irradiate agri-food products. This irradiator is not dedicated to SIT programs due to its geometry that does not allow to obtain a dose uniformity ratio (DUR) recommended for such applications. This article presents a Monte Carlo study to investigate the feasibility of using the panoramic gamma irradiator at the National Institute for Agronomic Research (NIAR) of Tangier, Morocco, to setting up SIT methods and contributing to Ceratitis control programs. The Monte Carlo method was used to simulate the concrete bunker in which the panoramic gamma irradiator is installed. To obtain a recommended DUR required for SIT programs, two cells similar of the Gammacell-220 irradiator, which is mainly used in the SIT programs around the world, were simulated inside the concrete bunker. The simulation and calculations were performed using the MCNPX-2.7e Monte Carlo simulation code. It is demonstrated that at both investigated positions, the spatial distribution of dose rates in the two modeled irradiation cells, which were similar to a gammacell-220 irradiator cell, are uniform enough that the cells can be used for SIT programs. It is concluded that the panoramic irradiator at NIAR can be used to contribute to the control of Mediterranean fly pest and other insect pests in Morocco.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

source of the panoramic 60Co irradiator at the National Institute for Agronomic Research (NIAR), Tangier, Morocco

Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

Download references

Funding

The authors did not receive support from any organization for the submitted work.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Adil Aknouch.

Ethics declarations

Conflict of interest

The authors declare they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Aknouch, A., El-ouardi, Y., Hamroud, L. et al. A Monte Carlo study to investigate the feasibility to use the Moroccan panoramic irradiator in sterile insect technique programs. Radiat Environ Biophys 60, 673–679 (2021). https://doi.org/10.1007/s00411-021-00934-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00411-021-00934-6

Keywords

Navigation