Abstract
Mediterranean fly pest (Ceratitis) is one of the most destructive pests of fruit species in Morocco. The sterile insect technique (SIT) is an environmentally friendly strategy that uses ionizing radiation to sterilize adult insects. Morocco has a panoramic gamma irradiator used to irradiate agri-food products. This irradiator is not dedicated to SIT programs due to its geometry that does not allow to obtain a dose uniformity ratio (DUR) recommended for such applications. This article presents a Monte Carlo study to investigate the feasibility of using the panoramic gamma irradiator at the National Institute for Agronomic Research (NIAR) of Tangier, Morocco, to setting up SIT methods and contributing to Ceratitis control programs. The Monte Carlo method was used to simulate the concrete bunker in which the panoramic gamma irradiator is installed. To obtain a recommended DUR required for SIT programs, two cells similar of the Gammacell-220 irradiator, which is mainly used in the SIT programs around the world, were simulated inside the concrete bunker. The simulation and calculations were performed using the MCNPX-2.7e Monte Carlo simulation code. It is demonstrated that at both investigated positions, the spatial distribution of dose rates in the two modeled irradiation cells, which were similar to a gammacell-220 irradiator cell, are uniform enough that the cells can be used for SIT programs. It is concluded that the panoramic irradiator at NIAR can be used to contribute to the control of Mediterranean fly pest and other insect pests in Morocco.
Similar content being viewed by others
References
Aknouch A, Elouardi Y, Mouhib M et al (2020a) New approach to make cylindrical packaging products in rotation around their fixed axis during irradiation in the Monte Carlo simulation. Mosc Univ Phys Bull 75:447–450. https://doi.org/10.3103/S0027134920050045
Aknouch A, Mouhib M, Sebihi R et al (2020b) Monte Carlo simulation of the dose rate distribution of a Moroccan panoramic gamma irradiator using the MCNPX code. Moscow Univ Phys 75:35–38. https://doi.org/10.3103/S0027134920010026
Ami EB, Yuval B, Jurkevitch E (2010) Manipulation of the microbiota of mass-reared Mediterranean fruit flies Ceratitis capitata (Diptera: Tephritidae) improves sterile male sexual performance. ISME J 4:28–37. https://doi.org/10.1038/ismej.2009.82
Bakri A, Mehta K, Lance DR (2005) Sterilizing insects with ionizing radiation. In: Dyck VA, Hendrichs J, Robinson AS (eds) Sterile insect technique: principles and practice in area-wide integrated pest management. Springer, Netherlands, pp 233–268
Chu RDH (1990) Dosimetry studies to determine optimum processing parameters to minimize dose variations in non-uniform product. Int J Radiat Appl Instrum Part C Radiat Phys Chem 35:841–844. https://doi.org/10.1016/1359-0197(90)90327-E
Dridi W, Daoudi M, Farah K, Hosni F (2020) Monte Carlo validation of dose mapping for the Tunisian Gamma Irradiation Facility using the MCNP6 code. Radiat Phys Chem 173:108942
Dyck VA, Hendrichs J, Robinson AS (eds) (2021) Sterile insect technique: principles and practice in area-wide integrated pest management, 2nd edn. CRC Press, Boca Raton
El-ouardi Y, Dadouch A, Aknouch A et al (2020) Comparative study between Geant4, MCNP6 and experimental results against gamma radiation comes from a cobalt-60 source. Moscow Univ Phys 75:507–511. https://doi.org/10.3103/S0027134920050033
Farah K, Jerbi T, Kuntz F, Kovacs A (2006) Dose measurements for characterization of a semi-industrial cobalt-60 gamma-irradiation facility. Radiat Meas 41:201–208. https://doi.org/10.1016/j.radmeas.2005.03.003
Gual MR, Pereira C, Mesquita AZ (2019) Application of a new source model of a panoramic gamma irradiator on dose map formation in an irradiated product. Appl Radiat Isot 144:87–92. https://doi.org/10.1016/j.apradiso.2018.12.002
ISO/ASTM51607 (2013) Practice for use of the alanine-EPR dosimetry system. Annu. B. ASTM Stand. ASTM Int., West Conshohocken, PA: ASTM International. In: ISO. https://www.iso.org/cms/render/live/en/sites/isoorg/contents/data/standard/06/29/62955.html. Accessed 9 Jun 2021
Kadri O, Gharbi F, Farah K (2005) Monte Carlo improvement of dose uniformity in gamma irradiation processing using the GEANT4 code. Nucl Instrum Methods Phys Res Sect B 239:391–398. https://doi.org/10.1016/j.nimb.2005.05.052
Mastrangelo T, Parker AG, Jessup A et al (2010) A new generation of X ray irradiators for insect sterilization. J Econ Entomol 103:85–94. https://doi.org/10.1603/EC09139
Meyer MD, Robertson MP, Peterson AT, Mansell MW (2008) Ecological niches and potential geographical distributions of Mediterranean fruit fly (Ceratitis capitata) and Natal fruit fly (Ceratitis rosa). J Biogeogr 35:270–281. https://doi.org/10.1111/j.1365-2699.2007.01769.x
Nasreddine A, Kuntz F, El Bitar Z (2021) Absorbed dose to water determination for kilo-voltage X-rays using alanine/EPR dosimetry systems. Radiat Phys Chem 180:108938. https://doi.org/10.1016/j.radphyschem.2020.108938
Oliveira C, Salgado J (2001) Isodose distributions and dose uniformity in the Portuguese gamma irradiation facility calculated using the MCNP code. Radiat Phys Chem 61:791–793. https://doi.org/10.1016/S0969-806X(01)00406-6
Ounalli L, Bhar M, Mejri A et al (2017) Combining Monte Carlo simulations and dosimetry measurements for process control in the Tunisian cobalt-60 irradiator after three half lives of the source. Nucl Sci Tech 28:133. https://doi.org/10.1007/s41365-017-0289-5
Pelowitz DB, Durkee JW, Elson JS et al (2011) MCNPX 2.7.0 extensions. Los Alamos National Lab (LANL), Los Alamos
Pérez-Staples D, Shelly TE, Yuval B (2013) Female mating failure and the failure of ‘mating’ in sterile insect programs. Entomol Exp Appl 146:66–78. https://doi.org/10.1111/j.1570-7458.2012.01312.x
Rezaeian P, Ataenia V, Shafiei S (2017) An analytical method based on multipole moment expansion to calculate the flux distribution in gammacell-220. Radiat Phys Chem 141:339–345. https://doi.org/10.1016/j.radphyschem.2017.08.003
Sharpe PHG, Sephton JP, Chu RD (2000) Real time dosimetry measurements at an industrial irradiation plant. Radiat Phys Chem 57:687–690
Solanki RB, Prasad M, Sonawane AU, Gupta SK (2012) Probabilistic safety assessment for food irradiation facility. Ann Nucl Energy 43:123–130. https://doi.org/10.1016/j.anucene.2012.01.002
Soliman YS, Beshir WB, Abdel-Fattah AA, Abdel-Rehim F (2013) Dosimetric studies for gamma radiation validation of medical devices. Appl Radiat Isot 71:21–28. https://doi.org/10.1016/j.apradiso.2012.09.016
Yamaguchi H, Shimizu M, Morishita Y et al (2020) Development of postal dosimetry service using an alanine dosimeter in Japan. Radiat Meas 135:106339. https://doi.org/10.1016/j.radmeas.2020.106339
Funding
The authors did not receive support from any organization for the submitted work.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Aknouch, A., El-ouardi, Y., Hamroud, L. et al. A Monte Carlo study to investigate the feasibility to use the Moroccan panoramic irradiator in sterile insect technique programs. Radiat Environ Biophys 60, 673–679 (2021). https://doi.org/10.1007/s00411-021-00934-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00411-021-00934-6