Skip to main content
Account

Table 3 Experimental glass and olivine rim compositions in wt%

From: Fe2+–Mg partitioning between olivine and liquid at low oxygen fugacity: an experimental and thermodynamic framework

Name

Phase

n

SiO2

TiO2

Al2O3

Cr2O3

FeO*

MnO

MgO

CaO

Na2O

K2O

NiO

Totals

RKD-1

gl

46

47.2(4)

1.93(1)

11.2(1)

0.5(2)

11.64(23)

0.86(3)

15.29(28)

9.3(1)

0.72(4)

0.04(1)

 

98.92

 

ol

20

39.4(4)

0.01(2)

0.10(2)

0.44(2)

11.33(9)

0.67(1)

47.62(22)

0.30(2)

   

99.88

RKD-2

gl

48

47.8(4)

1.9(2)

11.5(2)

0.52(2)

10.48(23)

0.84(2)

15.18(21)

9.5(1)

1.13(4)

0.07(1)

 

99.05

 

ol

25

39.2(6)

0.01(1)

0.10(2)

0.45(2)

10.55(18)

0.68(1)

48.79(52)

0.30(1)

   

100.11

RKD-3

gl

20

48.0(1)

1.95(3)

12.2(1)

0.50(2)

10.14(8)

0.82(2)

14.63(8)

9.54(3)

1.04(5)

0.07(1)

0.02(2)

98.99

 

ol

15

40.1(3)

0.05(3)

0.09(1)

0.44(4)

10.20(8)

0.67(1)

46.96(18)

0.30(1)

  

0.17(2)

99.00

RKD-4

gl

20

47.9(2)

1.96(3)

12.4(1)

0.55(4)

10.11(6)

0.85(3)

14.71(9)

9.54(3)

0.69(4)

0.064(4)

0.01(1)

98.82

 

ol

10

40.3(1)

0.05(1)

0.08(1)

0.44(2)

10.07(4)

0.66(1)

47.14(11)

0.28(1)

  

0.14(1)

99.19

RKD-5

gl

20

48.2(1)

1.95(2)

12.09(4)

0.56(2)

11.13(7)

0.87(2)

14.97(10)

9.48(2)

0.48(4)

0.04(1)

0.06(2)

99.78

 

ol

15

40.0(3)

0.05(1)

0.08(1)

0.44(2)

10.97(9)

0.68(1)

46.79(17)

0.27(1)

  

0.33(2)

99.59

RKD-6

gl

18

48.6(1)

2.14(3)

13.3(1)

0.40(2)

10.93(5)

0.85(2)

12.53(8)

10.39(4)

0.35(3)

0.03(1)

0.08(2)

99.58

 

ol

12

39.6(1)

0.04(1)

0.07(1)

0.34(1)

12.42(4)

0.74(1)

45.18(15)

0.28(1)

  

0.53(2)

99.24

RKD-7

gl

19

47.1(1)

1.78(3)

11.2(1)

0.74(2)

11.37(8)

0.86(3)

17.51(15)

8.65(4)

0.29(4)

0.04(1)

0.04(2)

99.55

 

ol

12

40.0(2)

0.04(1)

0.09(1)

0.50(2)

9.74(3)

0.60(1)

47.48(17)

0.27(1)

  

0.22(1)

98.91

RKD-8

gl

20

47.9(1)

0.60(2)

17.8(1)

0.03(1)

8.26(5)

0.49(2)

11.84(8)

11.29(3)

1.6(1)

0.08(1)

0.03(1)

99.90

 

ol

7

40.0(2)

0.01(1)

0.08(1)

0.03(1)

9.95(7)

0.47(1)

47.54(12)

0.36(1)

  

0.28(1)

98.71

RKD-9

gl

20

48.3(1)

0.60(2)

18.0(1)

0.03(1)

7.78(6)

0.48(2)

12.36(7)

11.28(3)

1.00(4)

0.07(1)

0.02(1)

99.90

 

ol

11

40.3(2)

0.01(1)

0.07(2)

0.02(1)

9.21(5)

0.45(1)

48.30(14)

0.32(1)

  

0.16(2)

98.85

RKD-12

gl

15

48.4(1)

0.60(2)

17.72(5)

0.03(1)

8.11(6)

0.49(2)

12.41(4)

11.33(2)

1.34(5)

0.08(1)

0.02(2)

100.58

 

ol

15

40.5(1)

0.01(1)

0.07(2)

0.03(1)

9.58(12)

0.46(1)

48.25(18)

0.34(1)

  

0.20(2)

99.38

RKD-13

gl

20

51.2(1)

0.79(1)

15.5(1)

 

6.76(4)

0.48(2)

13.42(5)

11.64(4)

0.34(3)

0.02(1)

 

100.12

 

ol

14

40.8(2)

0.02(1)

0.05(2)

 

7.94(4)

0.42(1)

49.66(15)

0.30(1)

   

99.25

RKD-14

gl

20

51.2(1)

0.80(2)

15.4(1)

 

6.75(4)

0.49(2)

13.51(7)

11.77(3)

0.27(3)

0.02(1)

 

100.24

 

ol

10

41.2(1)

0.02(1)

0.04(1)

 

7.88(5)

0.42(1)

50.09(15)

0.30(1)

   

99.94

RKD-15

gl

20

52.2(1)

1.07(3)

15.6(1)

 

7.24(5)

0.51(2)

10.16(06)

12.89(4)

0.13(3)

0.008(4)

 

99.79

 

ol

10

40.4(3)

0.02(1)

0.04(2)

 

10.65(10)

0.54(1)

47.38(21)

0.34(1)

   

99.38

RKD-16

gl

21

50.6(2)

1.06(2)

14.6(1)

 

12.98(7)

0.50(2)

9.59(05)

11.25(3)

0.11(2)

0.00

 

100.65

 

ol

7

39.3(2)

0.02(1)

0.03(1)

 

18.28(15)

0.52(2)

41.56(12)

0.31(1)

   

100.05

RKD-17

gl

20

50.0(2)

1.08(2)

14.8(1)

 

13.04(8)

0.50(2)

9.53(06)

11.31(3)

0.09(2)

0.006(4)

 

100.43

 

ol

14

39.0(2)

0.02(1)

0.04(1)

 

18.33(10)

0.51(1)

41.28(13)

0.32(2)

   

99.53

RKD-19

gl

19

51.6(3)

1.02(2)

16.2(2)

0.03(1)

8.87(10)

0.60(2)

8.84(16)

12.1(1)

1.42(4)

0.12(1)

0.01(1)

100.82

 

ol

8

40.3(1)

0.03(1)

0.04(1)

0.04(1)

13.77(9)

0.70(1)

45.09(16)

0.39(1)

  

0.21(1)

100.59

RKD-20

gl

14

51.2(1)

0.99(2)

16.5(1)

0.04(1)

8.69(8)

0.60(2)

9.11(06)

12.14(4)

1.35(3)

0.11(1)

0.01(1)

100.69

 

ol

12

40.3(2)

0.03(1)

0.05(1)

0.04(1)

13.33(14)

0.68(1)

45.44(13)

0.38(1)

  

0.19(1)

100.42

RKD-21

gl

19

48.7(2)

2.04(3)

13.0(1)

 

16.28(10)

0.58(2)

6.90(05)

12.14(5)

0.22(2)

0.01(1)

 

99.93

 

ol

5

37.2(4)

0.03(2)

0.09(3)

 

26.44(13)

0.75(3)

34.12(34)

0.45(3)

   

99.14

RKD-22

gl

20

45.0(1)

1.10(2)

13.3(1)

 

23.44(12)

0.51(3)

5.92(04)

10.66(2)

0.08(2)

0.01(1)

 

100.02

 

ol

15

35.1(1)

0.04(1)

0.05(1)

 

36.31(14)

0.66(1)

26.28(12)

0.47(3)

   

98.92

RKD-23

gl

19

45.3(1)

1.09(2)

12.88(4)

 

23.18(9)

0.51(2)

6.00(05)

10.60(3)

0.07(2)

0.004(4)

 

99.63

 

ol

13

35.8(2)

0.03(1)

0.03(1)

 

35.51(35)

0.64(1)

27.43(30)

0.43(3)

   

99.86

RKD-24

gl

20

45.4(1)

1.11(2)

13.1(1)

 

23.34(11)

0.53(1)

6.03(04)

10.54(3)

0.08(2)

0.01(1)

 

100.07

 

ol

12

35.5(2)

0.03(1)

0.04(1)

 

35.64(14)

0.64(1)

27.20(11)

0.41(2)

   

99.44

RKD-25

gl

19

48.7(1)

2.07(3)

12.5(1)

0.24(1)

11.09(7)

0.17(2)

15.15(8)

10.02(4)

0.34(3)

0.04(1)

0.05(2)

100.34

 

ol

17

40.5(3)

0.04(1)

0.059(4)

0.17(1)

11.01(7)

0.14(1)

47.76(22)

0.26(1)

  

0.29(2)

100.24

RKD-26

gl

20

49.4(1)

2.10(3)

13.0(1)

0.43(2)

10.71(6)

0.84(3)

13.10(6)

10.32(2)

0.25(2)

0.03(1)

0.05(2)

100.29

 

ol

13

40.5(1)

0.04(1)

0.059(4)

0.35(1)

11.91(4)

0.72(1)

46.16(12)

0.26(1)

  

0.42(1)

100.38

RKD-28

gl

20

51.5(1)

0.80(2)

15.75(6)

 

6.67(4)

0.50(2)

13.36(4)

11.79(2)

0.21(2)

0.02(1)

 

100.63

 

ol

15

41.0(3)

0.02(1)

0.04(1)

 

7.96(6)

0.42(1)

50.08(17)

0.29(1)

   

99.73

RKD-29

gl

20

51.8(1)

0.78(2)

15.52(7)

 

6.70(5)

0.49(2)

13.76(5)

11.74(4)

0.28(2)

0.02(1)

 

101.07

 

ol

19

41.3(2)

0.02(1)

0.04(1)

 

7.72(5)

0.41(1)

50.58(14)

0.30(1)

   

100.37

RKD-30

gl

20

51.5(1)

0.75(2)

15.19(7)

 

6.75(5)

0.50(2)

14.34(6)

11.54(4)

0.23(2)

0.02(1)

 

100.79

 

ol

18

41.1(2)

0.02(1)

0.04(1)

 

7.57(4)

0.40(1)

50.67(12)

0.30(2)

   

100.09

RKD-31

gl

21

45.1()

1.03(2)

13.47(6)

 

22.88(8)

0.52(2)

6.36(5)

10.61(3)

0.05(2)

0.006(4)

 

100.02

 

ol

17

36.1(2)

0.05(1)

0.04(1)

 

34.43(43)

0.62(2)

28.49(41)

0.41(4)

   

100.13

RKD-32

gl

21

45.1(1)

1.02(2)

13.47(6)

 

22.54(12)

0.51(2)

6.37(4)

10.56(2)

0.04(2)

0.004(4)

 

99.63

 

ol

6

36.0(2)

0.04(1)

0.04(2)

 

33.89(29)

0.60(1)

28.67(20)

0.42(1)

   

99.62

RKD-33

gl

20

45.5(1)

1.03(2)

13.50(6)

 

22.47(12)

0.51(2)

6.52(4)

10.56(2)

0.06(2)

0.005(4)

 

99.98

 

ol

13

36.2(2)

0.04(1)

0.04(1)

 

34.42(12)

0.62(1)

28.42(12)

0.42(2)

   

100.13

RKD-34

gl

20

44.9(1)

1.07(3)

13.42(6)

 

22.78(9)

0.52(2)

6.25(5)

10.65(2)

0.05(2)

0.01(1)

 

99.74

 

ol

17

36.1(3)

0.04(1)

0.04(2)

 

34.18(21)

0.62(1)

28.56(19)

0.42(3)

   

99.96

RKD-35

gl

20

45.0(1)

1.07(2)

13.55(6)

 

22.32(1)

0.50(2)

6.40(4)

10.57(2)

0.07(3)

0.005(4)

 

99.47

 

ol

16

35.8(2)

0.03(1)

0.04(1)

 

34.42(22)

0.62(1)

28.21(18)

0.42(3)

   

99.58

  1. Reported values correspond to the mean composition of each phase measured in each experiment; the numbers in parentheses correspond to one standard deviation in terms of the least unit cited, i.e., 11.64(23) = 11.64 ± 0.23(1σ), or 11.33(9) = 11.33 ± 0.09(1σ). gl – glass, ol – olivine. n = number of analyses that were used to calculate averages and standard deviations. All olivine compositions come from analyses of olivine rims. The following primary standards were used: Si – for olivine, forsterite; for glass, VG-2, Ti – TiO2, Al – for olivine, Al2O3; for glass, VG-2, Cr – Cr2O3, Fe – fayalite, Mn – tephroite, Mg – forsterite, Ca – for olivine, anorthite; for glass, VG-2, Na – albite, K – microcline, Ni – NiO. The Mean Atomic Number (MAN) protocol was used to calculate backgrounds. On-peak counting times were as follows: Si – 70 s, Ti – 60 s, Al – 100 s, Cr – 70 s, Fe – 50 s, Mn – 40 s, Mg – 50 s, Ca – 100 s, Na – 20 s, K –20 s, Ni – 30 s. Note that the olivines and glasses in RKD-1 and RKD-2 were measured using a different analytical protocol than the remaining experiments (count times were shorter) and NiO was not analyzed in this session. The count times for these two experiments were as follows: Si – 30 s, Ti – 30 s, Al – 30 s, Cr – 30 s, Fe – 25 s, Mn – 30 s, Mg – 30 s, Ca – 30 s, Na – 20 s, K – 20 s, Ni – not analyzed