European Archives of Oto-Rhino-Laryngology

, Volume 268, Issue 10, pp 1421–1425 | Cite as

Safety and patient selection of totally implantable hearing aid surgery: Envoy system, Esteem

  • Faramarz Memari
  • Alimohamad Asghari
  • Ahmad Daneshi
  • Ali Jalali
Otology

Abstract

Patient’s low compliance of conventional hearing aids has lead to innovation of totally implantable hearing devices such as Esteem, Envoy system. This study was designed to evaluate safety of device implantation, patient’s hearing gain, importance of anatomic landmarks, and to describe suitable criteria for patient selection. Via a non-randomized controlled clinical trial, ten patients with moderate-to-severe sensorineural hearing loss were implanted from 2007 to 2009. Mean follow-up period was 29.4 months. Correlation of pre-operative temporal bone CT scan anatomy with postoperative outcome was evaluated. Except one, all other implanted devices are active and patients’ overall average hearing gain are similar to conventional hearing aids (10–22 dB), but patients reported relatively better subjective sound quality compared with their pre-operative conventional hearing aids. One implanted device was explanted in a patient due to facial weakness and low-hearing gain. Revision surgery was done successfully in another patient secondary to excessive bone growth. Totally implantable hearing device surgery seems to be relatively safe and correct patient selection could lead to good outcomes. Lateral location of facial nerve, sclerotic mastoid air cells and narrow facial recess space seems to be related to postoperative complications.

Keywords

Temporal bone anatomy Facial nerve Implantable hearing aid Esteem Patient selection 

References

  1. 1.
    Cruickshanks KJ, Tweed TS, Wiley TL, Klein BE, Klein R, Chappell R et al (2003) The 5-year incidence and progression of hearing loss: the epidemiology of hearing loss study. Arch Otolaryngol Head Neck Surg 129:1014–1016CrossRefGoogle Scholar
  2. 2.
    Cruickshanks KJ, Wiley TL, Tweed TS, Klein BE, Klein R, Mares-Perlman JA et al (1998) Prevalence of hearing loss in older adults in Beaver Dam, Wisconsin: the epidemiology of hearing loss study. Am J Epidemiol 148:879–886PubMedGoogle Scholar
  3. 3.
    Leysieffer H, Baumann JW, Mayer R, Müller D, Müller G, Schön T et al (1998) First implantation of a totally implantable electronic hearing aid in patients with inner ear hearing loss. HNO 46:853–863PubMedCrossRefGoogle Scholar
  4. 4.
    Chen D, Backous D, Arriaga M, Garvin R, Kobylek D, Littman T et al (2004) Phase 1 clinical trial results of the envoy system: a totally implantable middle ear device for sensorineural hearing loss. Otolaryngol Head Neck Surg 131:904–916PubMedCrossRefGoogle Scholar
  5. 5.
    Barbara M, Manni V, Monini S (2009) Totally implantable middle ear device for rehabilitation of sensorineural hearing loss: preliminary experience with the Esteem® Envoy. Acta otol 129:429–432CrossRefGoogle Scholar

Copyright information

© Springer-Verlag 2011

Authors and Affiliations

  • Faramarz Memari
    • 1
  • Alimohamad Asghari
    • 2
  • Ahmad Daneshi
    • 1
  • Ali Jalali
    • 2
  1. 1.Department of ORL and HNS, Rasool-e-Akram Medical CenterTehran University of Medical Sciences and Health Services (TUMS)TehranIran
  2. 2.ENT and HNS Research Center, Rasool-e-Akram Medical CenterTehran University of Medical Sciences and Health Services (TUMS)TehranIran

Personalised recommendations