Abstract
In otorhinolaryngologist’s experience the nasal out-breath of people affected by chronic nasal or paranasal infections may be characterized by peculiar odours. In a previous study we showed that an electronic nose (EN), examining nasal out breath was able to distinguish subjects affected by chronic rhinosinusitis from healthy subjects. The present study is aimed at analysing the intensity and the quality of the odorous components present in the air expired by patients affected by rhinosinusitis, using a new EN based on gas-chromatography and surface acoustic wave analysis. In the gas-chromatographic tracings of the pathologic subjects there were six peaks, which were not present in control group cases. These peaks correspond to odorous components, whose chemical composition ranges from C6 to C14. Peaks obtained were compaired with other tracings revealed from specific bacterial and fungal cultures analyses and we appreciated some analogies.
Similar content being viewed by others
References
Casalinuovo IA, Di Pierro D, Bruno E, Di Francesco P, Coletta M (2005) Experimental use of a new surface acoustic wave sensor for the rapid identification of bacteria and yeasts. Lett Appl Microbiol 42(1):24–29
Gardner JW (1991) Detection of vapours and odours from a multisensor array using pattern recognition. Part І. Principal component and cluster analysis. Sens Actuators B 4:109–115
Gardner JW, Bartlett N (1994) A brief history of electronic nose. Sens Actuators B 18:211–220
Harper WJ (2001) The strengths and weaknesses of the electronic nose. Adv Exp Med Biol 488:59–71
Hartmann J, Auge J, Hauptmann P (1994) Using the quartz-crystal-microbalance principle for gas detection with reversible and irreversible sensors. Sens Actuators B 18:429–433
Hines EL, Llobet E, Gardner JW (1999) Electronic noses: a review of signal processing techniques. IEE Proc Circuits Devices Syst 146:297–310
McEntegart CM, Penrose WR, Strathmann S, Stetter JR (2000) Detection and discrimination of coliform bacteria with gas sensor arrays. Sens Actuators 70:170–176
Mohamed EI, Bruno E, Linder R, Alessandrini M, Di Girolamo A, Poppl SJ, Puija A, De Lorenzo A (2003) A novel method for diagnosing chronic rhinosinusitis based on an electronic nose. An Otorrinolaringol Ibero Am 35:447–457
Percodani J, Serrano E, Uro-Coste E, Reyre J, Delisle MB, Abbal M, Linas MD, Recco P, Pessey JJ (1999) Does allergic fungal sinusitis exist? Preliminary results of a prospective study. Ann Otolaryngol Chir Cervicofac 116:78–84
Roh YR, Lee YJ, Kim HB, Cho HM, Baik S (1998) Development of a SAW gas sensor for monitoring SO2 gas. Sens Actuators A 64:173–178
Staples EJ (2000) The zNose, a new electronic nose using acoustic technology. Acoustical Society of America, Paper Number 2aEA4
Staples EJ (1999) A new electronic nose. Sensors 16:33–40
Staples EJ, Watson GW (1998) A gas chromatograph incorporating an innovative new surface acoustic wave (SAW) detector. In: Pittcon conference, 1–5 March, New Orleans, Louisiana, Paper 1583CP
Van Cauwenberge PB, Inels KJ, Bachert C, Wang DY (1997) Microbiology of chronic sinusitis. Acta Otorhinolaryngol 51:239–246
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bruno, E., Alessandrini, M., Ottaviani, F. et al. Can the electronic nose diagnose chronic rhinosinusitis? A new experimental study. Eur Arch Otorhinolaryngol 265, 425–428 (2008). https://doi.org/10.1007/s00405-007-0477-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00405-007-0477-8