Abstract
The aim of this study was to determine the degree and reversibility of hearing loss (HL) following spinal anesthesia with an objective audiometric test: otoacoustic emissions (OAE). Eleven patients (22 ears) who were undergoing surgery under spinal anesthesia were included in this study. Transient-evoked otoacoustic emissions (TEOAE) and distortion product otoacoustic emissions (DPOAE) were evaluated 1 day before the operation and postoperative day 1, 2, and 15. DPOAE were recorded as DPgram and input/output functions (I/O). The emission amplitudes of the TEOAE and DPOAE of right and left ears were found to be affected immediately after the surgery and progressive improvement detected with full recovery within postoperative 15 days. These changes were mainly at around 1,500–3,000 Hz. None of the patients had permanent OAE amplitude deterioration. Transient HL may occur more often than it is generally assumed, and the symptoms might not be recognized. OAE is an effective and objective way of evaluating the HL in this particular group of patients. We suggest informing patients about this transient HL for medicolegal issues.
Similar content being viewed by others
References
Wang LP (1986) Sudden bilateral hearing loss after spinal anesthesia: a case report. Acta Anaesthesiol Scand 30:412–413
Wang LP, Fog J, Bove M (1987) Transient hearing loss following spinal anesthesia. Anesthesia 42:1258–1263
Wang LP, Lundberg L, Magnusson M, Törnebrandt K (1993) Auditory function after spinal anesthesia. Reg Anesth 18:162–165
Oncel S, Hasgeli L, Zafer Uguz M, Savacı S, Onal K, Oyman S (1992) The effect of epidural anesthesia and size of spinal needle on post-operative hearing loss. J Laryngol Otol 106:783–787
Kilickan L, Gurkan Y, Aydin O, Etiler N (2003) The effect of combined spinal-epidural (CSE) anesthesia and size of spinal needle on postoperative hearing loss after elective caesarean section. Clin Otolaryngol 28:267–272
Schaffartzik W, Hirsch J, Frickmann F, Kuhly P, Ernst A (2000) Hearing loss after spinal and general anesthesia: a comparative study. Anesth Analg 91:1466–1472
Fog J, Wang LP, Sundberg A, Mucchiano C (1990) Hearing loss after spinal anesthesia is related to needle size. Anesth Analg 70:517–522
Marchbanks RJ (1996) Hydromechanical interactions of the intracranial and intralabyrinthine fluids. In: Ernst A, Marchbanks R, Sami M (eds) Intracranial and intralabyrinthine fluids: basic aspects and clinical applications. Springer, Berlin Heidelberg New York, pp 51–61
Walsted A (1998) Effects of cerebrospinal fluid loss on auditory system. Dan Med Bull 45:268–281
Lonsbury-Martin BL, Martin BL, Harris FP, Stagner BB, Hawkins MD, Martin GK (1990) Distortion product emissions in humans: basic properties in normally hearing subjects. Ann Otol Rhinol Larngol 99:3–14
Lonsbury-Martin BL, Martin GK (1990) The clinical utility of distortion-product otoacoustic emissions. Ear Hear 11:90–93
Panning B, Laubert A (1985) Transient low frequency hearing loss and facial paralysis following spinal anesthesia. A case report. Anaesthesist 34:402–404
Panning B, Mehler D, Lehnhardt E (1983) Transient low-frequency hypoacousia after spinal anaesthesia. Lancet 2:582
Panning B, Lehnhardt E, Mehler D (1984) Transient low-frequency hearing loss following spinal anaesthesia. Anaesthesist 33:593–595
Gultekin S, Ozcan S (2002) Does hearing loss after spinal anesthesia differ between young and elderly patients? Anesth Analg 94:1318–1320
Hall AJ, Lutman ME (1999) Methods for early identification of noise-induced hearing loss. Audiology 38:277–280
Michel O, Brusis T (1992) Hearing loss as a sequel of lumbar puncture. Ann Otol Rhinol Laryngol 101:390–394
Frank AM, Alexiou C, Hulin P, Janssen T, Arnold W, Trappe AE (2000) Non-invasive measurement of intracranial pressure changes by otoacoustic emissions (OAEs)- a report of preliminary data. Zentralbl Neurochir 61:177–180
Malhotra SK, Joshi M, Grover S, Sharma SC, Dutta A (2002) Auditory function following spinal analgesia: comparison of two spinal needles. Eur J Anaesthesiol 19:69–72
Sundberg A, Wang LP, Fog J (1992) Influence on hearing of 22 G Whitacre and 22 G Quincke needles. Anesthesia 47:981–983
Finegold H, Mandell G, Vallejo M, Ramanathan S (2002) Does spinal anesthesia cause hearing loss in the obstetric population? Anesth Analg 95:198–203
Ok G, Tok D, Erbuyun K, Aslan A, Tekin I (2004) Hearing loss does not occur in young patients undergoing spinal anesthesia. Reg Anesth Pain Med 29:430–433
Wemama JP, Delecroix M, Nyarwaya JB, Krivosic-Horber R (1996) Permanent unilateral vestibulocochlear dysfunction after spinal anesthesia. Anesth Analg 82:406–408
Kilickan L, Gürkan Y, Ozkarakas H (2002) Permanent sensorineural hearing loss following spinal anesthesia. Acta Anaesthesiol Scand 46:1155–1157
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Karatas, E., Göksu, S., Durucu, C. et al. Evaluation of Hearing Loss after Spinal Anesthesia with Otoacoustic Emissions. Eur Arch Otorhinolaryngol 263, 705–710 (2006). https://doi.org/10.1007/s00405-006-0049-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00405-006-0049-3