Skip to main content

Advertisement

Log in

Vacuum application through a nonfully dilated cervix: a viable option

  • Original Article
  • Published:
Archives of Gynecology and Obstetrics Aims and scope Submit manuscript

Abstract.

The aim of this cross-sectional study was to assess the feasibility of vacuum delivery through a nonfully dilated cervix. The study group consisted of 39 women with vacuum deliveries through a nonfully dilated cervix larger than 9 cm and station of the head at S or more +2 cm. These were compared to a control group of 215 vacuum deliveries at a fully dilated cervix and 46 women who underwent cesarean section at a nonfully dilated cervix larger than 9 cm. The main indication for vacuum extraction in the study group was fetal distress and in the control groups prolonged 2nd stage, dysfunctional labor and fetal distress. Maternal and neonatal morbidity was low and not different between the groups. Neonatal well being, evaluated by cord pH and 5-min Apgar score, was not different. Based on predefined criteria, vacuum extraction through a nonfully dilated cervix is a viable alternative to emergency cesarean section and is apparently not associated with higher maternal or infant morbidity.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Altaras M, Potashnik G, Ben-Adereth N, Leventhal H (1974) The use of vacuum extraction in cases of cord prolapse during labor. Am J Obstet Gynecol 118:824–830

    Google Scholar 

  2. Benedetti TJ (1999) Birth injury and method of delivery. N Engl J Med 341:1758–1789

    Google Scholar 

  3. Chalmers JA, Prakash A (1971) Vacuum extraction initiated during the first stage of labour. J Obstet Gynaecol Br Commonwealth 78:554–558

    Google Scholar 

  4. Cunningham FG, MacDonald PC, Gant NF, Leveno KJ, Gilstrap LC, Hankins GDV, Clark SL (1997) Operative vaginal delivery. In: Williams obstetrics, 20th edn. Prentice-Hall, New Jersey 473–494

  5. Huntingford (1961) The vacuum extractor in the treatment of delay in the first stage of labor. Lancet II:1054–1057

  6. Inman SE (1969) The use of the vacuum extractor in the first stage of labour. J Obstet Gynaecol Br Commonwealth 76:354–358

    Google Scholar 

  7. Lucas MJ (1994) The role of vacuum extraction in modern obstetrics. Clin Obstet Gynecol 37:794–805

    Google Scholar 

  8. Towner D, Castro MA, Eby-Wilkens E, Gilbert WM (1999) Effect of mode of delivery in nulliparous women on neonatal intracranial injury. N Engl J Med 341:1709–1714

    Google Scholar 

  9. Williams MC (1995) Vacuum-assisted delivery. Clin Perinatol 22:933–952

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marek Glezerman.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sadan, O., Ginath, S., Gomel, A. et al. Vacuum application through a nonfully dilated cervix: a viable option. Arch Gynecol Obstet 268, 281–283 (2003). https://doi.org/10.1007/s00404-002-0372-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00404-002-0372-x

Keywords.

Navigation