Abstract.
The aim of this cross-sectional study was to assess the feasibility of vacuum delivery through a nonfully dilated cervix. The study group consisted of 39 women with vacuum deliveries through a nonfully dilated cervix larger than 9 cm and station of the head at S or more +2 cm. These were compared to a control group of 215 vacuum deliveries at a fully dilated cervix and 46 women who underwent cesarean section at a nonfully dilated cervix larger than 9 cm. The main indication for vacuum extraction in the study group was fetal distress and in the control groups prolonged 2nd stage, dysfunctional labor and fetal distress. Maternal and neonatal morbidity was low and not different between the groups. Neonatal well being, evaluated by cord pH and 5-min Apgar score, was not different. Based on predefined criteria, vacuum extraction through a nonfully dilated cervix is a viable alternative to emergency cesarean section and is apparently not associated with higher maternal or infant morbidity.
Similar content being viewed by others
References
Altaras M, Potashnik G, Ben-Adereth N, Leventhal H (1974) The use of vacuum extraction in cases of cord prolapse during labor. Am J Obstet Gynecol 118:824–830
Benedetti TJ (1999) Birth injury and method of delivery. N Engl J Med 341:1758–1789
Chalmers JA, Prakash A (1971) Vacuum extraction initiated during the first stage of labour. J Obstet Gynaecol Br Commonwealth 78:554–558
Cunningham FG, MacDonald PC, Gant NF, Leveno KJ, Gilstrap LC, Hankins GDV, Clark SL (1997) Operative vaginal delivery. In: Williams obstetrics, 20th edn. Prentice-Hall, New Jersey 473–494
Huntingford (1961) The vacuum extractor in the treatment of delay in the first stage of labor. Lancet II:1054–1057
Inman SE (1969) The use of the vacuum extractor in the first stage of labour. J Obstet Gynaecol Br Commonwealth 76:354–358
Lucas MJ (1994) The role of vacuum extraction in modern obstetrics. Clin Obstet Gynecol 37:794–805
Towner D, Castro MA, Eby-Wilkens E, Gilbert WM (1999) Effect of mode of delivery in nulliparous women on neonatal intracranial injury. N Engl J Med 341:1709–1714
Williams MC (1995) Vacuum-assisted delivery. Clin Perinatol 22:933–952
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sadan, O., Ginath, S., Gomel, A. et al. Vacuum application through a nonfully dilated cervix: a viable option. Arch Gynecol Obstet 268, 281–283 (2003). https://doi.org/10.1007/s00404-002-0372-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00404-002-0372-x