Abstract
A discontinuous or thin cement mantle of a socket is associated with increased polyethylene wear and cement fractures. In a retrospective radiological analysis we examined the quality of the cement mantle in cups without (group I = 100 Charnley-Mueller cups) and with (group II = 100 Contemporary cups, Howmedica) bone cement spacers. Under-filling (0–2 mm) and over-filling (> 8 mm) of the cement mantle were noted and classified. Statistics show significantly less under-filling of the cement mantle in group II than in group I (P = 0.001), in particular when comparing separate cup regions (thirds; P << 0.001). Furthermore, there is no significant difference in the frequency of overfilling with cement between groups I and II (P = 0.108). To sum up, utilization of an acetabular component with preformed bone cement spacers considerably improves the quality of the cement mantle without additional cost.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Received: 3 February 1998
Rights and permissions
About this article
Cite this article
Lichtinger, T., Müller, R. Improvement of the cement mantle of the acetabular component with bone cement spacers . Arch Orth Traum Surg 118, 75–77 (1998). https://doi.org/10.1007/s004020050315